Difference between revisions of "End-Scan Using the Scissor Motion"

From ATTWiki
Jump to: navigation, search
(Measure Setup)
(About the Scissor Orientation - Easy But Least Precise)
 
(22 intermediate revisions by one user not shown)
Line 5: Line 5:
 
How to perform quick scissor motion end-scans.<br><br>
 
How to perform quick scissor motion end-scans.<br><br>
 
* Back to [[VTube-LASER]]
 
* Back to [[VTube-LASER]]
 +
* See [[End-Scan Technique Research]]
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
Line 14: Line 15:
  
  
===Why the End-Scan technique is important===
+
===About the Scissor Orientation - Easy But Least Precise===
  
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=500>
 
<td width=500>
This end-scan method is useful for ease-of-use and quickness.
+
This end-scan method is useful for ease-of-use and quickness, however it is the least precise of the techniques.
 
<br><br>
 
<br><br>
Please keep in mind that our tests show that it is the least precise of the techniques that we recommend.
+
You can expect about 0.1 inches (2.5mm) of repeatability in end lengths when using this method for end scans.
 
<br><br>
 
<br><br>
We also recommend the [[End-Scan Using the End Wall]] technique and the most precise [[End-Scan Using End Targets]].
+
We also recommend these techniques:
 +
 
 +
* [[End-Scan Using the End Wall]]  
 +
* [[End-Scan Using End Targets]] (most precise)
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
Line 29: Line 33:
 
</tr>
 
</tr>
 
</table>
 
</table>
 
  
 
===Measure Setup===
 
===Measure Setup===
Line 40: Line 43:
 
* Set Measure Setup - LASER Tab: End-scan stripes = 5
 
* Set Measure Setup - LASER Tab: End-scan stripes = 5
 
* Set Measure Setup - LASER Tab: Split bend stripes = 5
 
* Set Measure Setup - LASER Tab: Split bend stripes = 5
* Set Measure Setup =- Scan Rates Tab: Set all rates to TIMER for all scan types.
+
* Set Measure Setup = Scan Rates Tab: Set all rates to TIMER for all scan types.
* Set Measure Setup =- Scan Rates Tab: Set the Scan Rates TIMER is set to 0 for all TIMERS.
+
* Set Measure Setup = Scan Rates Tab: Set the Scan Rates TIMER is set to 0 for all TIMERS.
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
Line 54: Line 57:
 
<td width=300>
 
<td width=300>
 
* Align the scanner with a slight scissor angle across the end as is shown in the image on the right<br><br>
 
* Align the scanner with a slight scissor angle across the end as is shown in the image on the right<br><br>
 +
* Attempt to hold the laser motionless when collecting the stripes across the end to increase repeatability.<br><br>
 +
* Consistently place the line across the same area of the tube end from measure to measure.<br><br>
 
*Press the green button until VTube-LASER is finished scanning all the end stripes.<br><br>
 
*Press the green button until VTube-LASER is finished scanning all the end stripes.<br><br>
[[image:EndWithScissorCloseup.jpg|300px]]
+
[[image:EndWithScissorCloseup.jpg|300px]]<br><br>
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
Line 62: Line 67:
 
</tr>
 
</tr>
 
</table>
 
</table>
 
 
 
 
 
  
 
===Other Pages===
 
===Other Pages===

Latest revision as of 15:20, 1 December 2016

Vtube-laser logo.jpg How to perform quick scissor motion end-scans.

Vtube-laser 1 73.jpg


About the Scissor Orientation - Easy But Least Precise

This end-scan method is useful for ease-of-use and quickness, however it is the least precise of the techniques.

You can expect about 0.1 inches (2.5mm) of repeatability in end lengths when using this method for end scans.

We also recommend these techniques:

Measure Setup

  • Set System Options, Measure 2 Tab, "Maximum Number of LLP Points in String" to 3
  • Set Measure Setup - LASER Tab: The LASER defaults to ON for CYLINDERS and END-SCANS.
  • Set Measure Setup - LASER Tab: Cylinder stripes = 3 to 5
  • Set Measure Setup - LASER Tab: End-scan stripes = 5
  • Set Measure Setup - LASER Tab: Split bend stripes = 5
  • Set Measure Setup = Scan Rates Tab: Set all rates to TIMER for all scan types.
  • Set Measure Setup = Scan Rates Tab: Set the Scan Rates TIMER is set to 0 for all TIMERS.

How To Use This End-Scan Technique

  • Align the scanner with a slight scissor angle across the end as is shown in the image on the right

  • Attempt to hold the laser motionless when collecting the stripes across the end to increase repeatability.

  • Consistently place the line across the same area of the tube end from measure to measure.

  • Press the green button until VTube-LASER is finished scanning all the end stripes.

EndWithScissorCloseup.jpg

EndWithScissor.jpg

Other Pages