Difference between revisions of "CNC Bender v12-20100324"

From ATTWiki
Jump to: navigation, search
Line 24: Line 24:
  
 
__TOC__
 
__TOC__
 +
 +
 +
===[[image:Check.jpg|25px]] FIX - Rotation Recovery Logic===
 +
<table>
 +
<tr valign=top>
 +
<td width=300>
 +
When a rotation is stopped and recovered by stepping on the safety mat, the rotation direction would not always move the shortest distance and direction to recover.
 +
<br><br>
 +
This has been resolved so that all non-linear axes recover in the direction that is measured as the shortest possible.
 +
</td>
 +
<td>
 +
</td>
 +
</tr>
 +
 +
 +
<tr valign=top>
 +
<td width=300>
 +
</td>
 +
 +
<td>
 +
</td>
 +
</tr>
 +
 +
</table>
 +
 +
  
 
===[[image:Check.jpg|25px]] DEBUG - Machine Lube Timer Logic===
 
===[[image:Check.jpg|25px]] DEBUG - Machine Lube Timer Logic===

Revision as of 16:54, 25 March 2010

Cncv12procontrol withteachmode.jpg

Type of Upgrade: Significant Upgrade

Recovery Rotate Logic

V12mainmenu.jpg

Contents


Check.jpg FIX - Rotation Recovery Logic

When a rotation is stopped and recovered by stepping on the safety mat, the rotation direction would not always move the shortest distance and direction to recover.

This has been resolved so that all non-linear axes recover in the direction that is measured as the shortest possible.


Check.jpg DEBUG - Machine Lube Timer Logic

A small bug was removed in the machine lube timer that would prevent the machine lube from starting.

The Machine Lube feature shares the Constant Run List timer. This error was only encountered recently because we have begun running CNC Processor loops faster than in previous versions.

Check.jpg ADDED - Cycle Hold After Last Bend After Dies Open

This feature was requested so we added it to CNC Bender.

Now the bender will go into cycle hold after the last bend after the dies open if this option is switched ON in the last bend cell (part release) section.



Other Pages