Difference between revisions of "VTube-LASER v2.9.12"
(→25pxNEW - MINIMUM CLAMP LENGTH FILTER FOR CORRECTIONS) |
(→25pxNEW - MINIMUM CLAMP LENGTH FILTER FOR CORRECTIONS) |
||
Line 87: | Line 87: | ||
<td width=300> | <td width=300> | ||
− | This new filter is in | + | This new filter is in the new CORRECTION FILTER tab menu in Bender Setup.<br><br> |
We added this feature into Bender Setup to allow VTube-LASER to limit the shortening changes made to lengths between bends. For example, if the minimum clamp length is 50 mm and this filter is active, then any LENGTH correction that calculates a length less than 50 mm will be reset to the minimum of 50.<br><br> | We added this feature into Bender Setup to allow VTube-LASER to limit the shortening changes made to lengths between bends. For example, if the minimum clamp length is 50 mm and this filter is active, then any LENGTH correction that calculates a length less than 50 mm will be reset to the minimum of 50.<br><br> | ||
Revision as of 13:11, 14 August 2018
Revision 2.9.12Release Date: August 13, 2018
|
Contents |
NEW - LRA POPUP MENU COMMAND SPLITS ONE BEND INTO TWO FOR MORE ACCURATE MEASURING QUALIFICATION and BENDER CORRECTION
Splitting a bend into two adjacent half-bends manually is a bit complex. So we added this command to make it easy.
|
Follow these steps to setup VTube-LASER to split a bend then turn on "Split Bend Measuring"1 - Select the bend to split in an LRA grid. See VTube-LASER Split Bend Feature for details on the Split Bend measuring feature. |
NEW - MINIMUM CLAMP LENGTH FILTER FOR CORRECTIONS
This new filter is in the new CORRECTION FILTER tab menu in Bender Setup. When the filter limits the length reduction, then a dialog will appear before data is sent to the bender. The dialog will warn you with a message that at least one length correction was limited to the minimum clamp length. |
OTHER CHANGES
Other Pages
|