VTube-LASER v2.9.12

From ATTWiki
Jump to: navigation, search

Vtube-laser logo 1.96.png


Revision 2.9.12

Release Date: August 20, 2018
Current Build: 6


Vtube-laser v2.7 screenshot.png

Contents


Check.jpgNEW - NOTE LIST in PART SETUP For an UNLIMITED Number of Notes in a VTube Project

We received a request for more COMMENT and/or NOTE fields in Part Setup for VTube-LASER and VTube-STEP.

We added the new UNLIMITED NOTE LIST - which allows for any number of notes per project.

  • All the notes can be exported in the BATCH EXPORT mode in the Report menu.

  • All the notes can be included in a standard report.

  • The notes are stored in the VTube project file.


Vtl v2.9.12 notelist.png





Video 88: VTube-LASER and VTube-STEP Unlimited NOTE LIST Feature

This video shows the new unlimited NOTE LIST feature that allows you to add any number of notes to a VTube project.

Vtl v2.9.12 notelist video.png



Check.jpgNEW - LRA POPUP MENU COMMAND SPLITS ONE BEND INTO TWO FOR MORE ACCURATE MEASURING QUALIFICATION and BENDER CORRECTION

Splitting a bend into two adjacent half-bends manually is a bit complex. So we added this command to make it easy.

This new "split a bend" command is useful for when a very high bend angle throws its intersection point far from the tube and then creates unreliably high swings in the tangent deviation and bender correction data.

After splitting a bend into two adjacent half-bends, you can use the SPLIT BEND measuring feature to scan the inside and outside of the actual bend to overcome this problem.

This new command is available in these grids:

  • Incremental LRA
  • Springback Compensated LRA
  • Absolute LRA

Vtl v2.9.12 splitbend into twobends.png



See VTube-LASER Split Bend Feature for details on how to use the Split Bend Measuring feature with high-angled bends.



Check.jpgNEW - MINIMUM CLAMP LENGTH FILTER FOR CORRECTIONS

This new filter is in the new CORRECTION FILTER tab menu in Bender Setup.

We added this feature into Bender Setup to allow VTube-LASER to limit the shortening changes made to lengths between bends. For example, if the minimum clamp length is 50 mm and this filter is active, then any LENGTH correction that calculates a length less than 50 mm will be reset to the minimum of 50.

When the filter limits the length reduction, then a dialog will appear before data is sent to the bender. The dialog will warn you with a message that at least one length correction was limited to the minimum clamp length.

Vtl v2.9.12 minimumclampfilter.png

When the Minimum Clamp filter is active and the filter lengthened a length between two bends, then this warning will display.

The dialog allows you to CONTINUE or STOP the send to the bender.

Vtl v2.9.12 minimumclampfilter warning.png





Check.jpg OTHER CHANGES

  • FIX - In the MASTER and MEASURED tube menus - the EXPORT combo drop down box was fixed so that the current choice is always the type of export that VTube performs.

  • FIX - The RECALL button in Bender Setup now enables properly depending on the communications protocol.

  • FIX - The Coping Print Preview screen does not load into memory during initialization unless it is being used. This prevents potential errors if no printer is installed in your setup.

  • CHANGE - Moved the demo parts to the "C:\Users\Public\Documents\VTube\Demo Files" folder during installation to clear up the default project folder for your parts.



Other Pages