Difference between revisions of "VTube-LASER v2.9.18"
(→25pxNEW - AUTOMATIC LASER SEPARATION Method for UniScan Mode) |
(→25pxNEW - AUTOMATIC LASER SEPARATION Method for UniScan Mode) |
||
| Line 30: | Line 30: | ||
<td width=300> | <td width=300> | ||
| − | |||
The NEW AUTOMATIC LASER SEPARATION method allows VTube-LASER to automatically control the UniScan separation distance between laser stripes based on the known MASTER tube length.<br><br> | The NEW AUTOMATIC LASER SEPARATION method allows VTube-LASER to automatically control the UniScan separation distance between laser stripes based on the known MASTER tube length.<br><br> | ||
This allows VTube-LASER to lay stripes closer on shorter straights to collect more data - while making VTube spread out stripes on longer sections - automatically.<br><br> | This allows VTube-LASER to lay stripes closer on shorter straights to collect more data - while making VTube spread out stripes on longer sections - automatically.<br><br> | ||
| Line 39: | Line 38: | ||
<td> | <td> | ||
| + | [[image:ra8_stripes.png|400px]]<br> | ||
[[image:vtl_v2.9.18_AutomaticLaserSeparation.png|180px]][[image:vtl_v2.9.18_AutomaticLaserSeparation_Graphic.png|700px]] | [[image:vtl_v2.9.18_AutomaticLaserSeparation.png|180px]][[image:vtl_v2.9.18_AutomaticLaserSeparation_Graphic.png|700px]] | ||
</td> | </td> | ||
Revision as of 01:29, 9 March 2019
|
Revision 2.9.18Release Date: March 8, 2019
|
NEW - AUTOMATIC LASER SEPARATION Method for UniScan Mode
|
The NEW AUTOMATIC LASER SEPARATION method allows VTube-LASER to automatically control the UniScan separation distance between laser stripes based on the known MASTER tube length. See the VTube-LASER UniScan Automatic Laser Separation Tutorial for more information. |
NEW - Bender Setup Window CORRECTION DATA MAPPING Adds Extreme Flexibility to Corrections
|
If you have to skip rows in bender setup data for avoidance moves, then this feature is important for you.
|
NEW - Move Bend Setup BLUE COLUMN Data Up or Down
|
Use this feature combined with Correction Data Mapptin to skip rows for avoidance moves.
|
NEW - BLM CMM Communications Protocol
| This protocol allows you to correct BLM benders using the BLM CMM protocol. This is now the recommended protocol for use with BLM benders. |
NEW - COMCO CSV Communications Protocol
| This protocol allows you to correct COMCO benders through the CSV file import and export. |
NEW - OMCG SVNET Communications Protocol
|
This protocol allows you to correct OMCG benders. |
NEW - Now VTube has THREE Default Radii
| Radius 1, Radius 2, and Radius 3 are now available in Part Setup. |
FIX - The Taskbar Icon Now Displays
| VTube-LASER users discovered that the taskbar icon did not always display. This has been fixed. |
Other Pages
- See VTube-LASER Addata ZModem Communications Protocol for more information.
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.
- See the tutorial on DCF - Dual Cylinder Fit
- See the tutorial on DCP - Diameter Cut Planes
- See VTube-LASER Cut Planes
- See How to Measure Tubes Attached to an Evaporator with the DCP Feature