(25px ENHANCED - Improved Error Handling and Dialogs)
(25px ENHANCED - Transfer of XYZ Data from Measuring Centers)
 
(19 intermediate revisions by one user not shown)
Line 37: Line 37:
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
The Hexagon DOCS software requires that the bender take in, store, and return the master centerline XYZ data.<br><br>
+
===Handling XYZ Data Transfers===
This is the first version of Benderlink that can handle the XYZ coordinates between the DOCS software and the Chiyoda / KEINS touchscreen benders.<br><br>
+
XYZ data is now transferred in both directions for storage in both the touch-screen bender controls and in Benderlink data files.<br><br>
 +
 
 +
===Handling RADIUS Data Transfers (For Radius Values Sent with the XYZ Data)===
 +
The RADIUS values sent with the XYZ data are stored only in the Benderlink data files.  They are not transferred to the bender control.  This ensures that the original design values are always returned to DOCs software during DOCs data RECALLS.<br><br>
 +
This feature was added for the Hexagon ROMER DOCS measuring software which requires that the MASTER XYZ and XYZ RADIUS data be returned from the bender during RECALL transfers.<br><br>
 
</td>
 
</td>
<td>
+
<td width=400>
 
[[image:benderlink_chiyodakeins_6.92_xyzcoordinates.png|400px]]<br><br>
 
[[image:benderlink_chiyodakeins_6.92_xyzcoordinates.png|400px]]<br><br>
 
</td>
 
</td>
Line 46: Line 50:
 
</table>
 
</table>
  
==[[image:Check.jpg|25px]] ENHANCEMENT - Better Error Recovery Handling for Disabled Buttons ==
+
==[[image:Check.jpg|25px]] NEW: About Button ==
  
 
<table cellpadding=20>
 
<table cellpadding=20>
 +
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
 
+
* An About button is added to the main interface in the top right cornerThis allows you to check the current version of Benderlink at any time.
Previous versions would disable the buttons on the user interface during transfer, but never enable them again if errors occurred.<br><br>
+
This has been resolved in this versionThe buttons will always enable even if an error occurs.
+
 
+
 
</td>
 
</td>
 
 
<td>
 
<td>
[[image:benderlink_chiyodakeins_6.91_screenshot_buttonsframed.png|400px]]
+
[[image:benderlink_chiyodakeins_6.92_aboutbutton.png|400px]]
</td>
+
</tr>
+
</table>
+
<br><br>
+
 
+
==[[image:Check.jpg|25px]] Other Changes ==
+
 
+
<table cellpadding=20>
+
 
+
<tr valign=top>
+
<td width=300>
+
* Corrupted data could shutdown communications for a single bender channel.  This version has a better filter for corrupted transmissions.
+
 
</td>
 
</td>
 
</tr>
 
</tr>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
* A new feature will check the executable file for unauthorized changes to the Benderlink executable file.
 
 
</td>
 
</td>
 
</tr>
 
</tr>

Latest revision as of 05:32, 13 January 2015

Blink keinschiyoda orangefire.jpg

Revision 6.92

Back to Benderlink for Chiyoda
Back to Benderlink for KEINS
Back to Benderlink for Chiyoda/KEINS Revisions

Blink keinschiyoda screens 6.1.jpg


Check.jpg UPDATED - The Embedded VTube-STEP is Now Version 1.99

The previous Benderlink had included version 1.95. This version includes VTube-STEP version 1.99 that improves the calculation of centerlines from rough solid models. This new version is embedded in this version of Benderlink.

Vtube-step-1.87 screenimage.png



Check.jpg ENHANCED - Transfer of XYZ Data from Measuring Centers

Handling XYZ Data Transfers

XYZ data is now transferred in both directions for storage in both the touch-screen bender controls and in Benderlink data files.

Handling RADIUS Data Transfers (For Radius Values Sent with the XYZ Data)

The RADIUS values sent with the XYZ data are stored only in the Benderlink data files. They are not transferred to the bender control. This ensures that the original design values are always returned to DOCs software during DOCs data RECALLS.

This feature was added for the Hexagon ROMER DOCS measuring software which requires that the MASTER XYZ and XYZ RADIUS data be returned from the bender during RECALL transfers.

Benderlink chiyodakeins 6.92 xyzcoordinates.png

Check.jpg NEW: About Button

  • An About button is added to the main interface in the top right corner. This allows you to check the current version of Benderlink at any time.

Benderlink chiyodakeins 6.92 aboutbutton.png



OTHER PAGES