VTube-LASER End Point Deviations

From ATTWiki
Revision as of 01:23, 2 December 2016 by Mcone (Talk | contribs)

Jump to: navigation, search

Vtube-laser logo 1.96.png This page describes how to find the END POINT deviations.

Vtl screen hd scanner without logo.png


Contents

Three Main End Point Deviations

There are three main end point deviation values calculated during an alignment of the MEASURED to the MASTER tube.

Vtl three end point deviations.png

END LENGTH Deviations

The end length deviations are found at the top of the Inspection menu.

These deviations show you how much to trim a part to make it fit within the current alignment better.

Vtl end length deviations.png

AFTER-TRIM Deviations

These are found in the first T1 value and the last T2 value in the Tangents grid.

These deviations show the expected radial deviation if the tube were trimmed.

Vtl after-trim deviations.png




Tangent Point Deviations in the Inspection Data Grid

The Tangent chart is represented by a grid of straights for each row with tangent points and midpoints for each straight:

  • T1 = Tangent 1 Deviation
  • MP = Midpoint Deviation
  • T2 = Tangent 2 Deviation

  • T1t = Tangent 1 Deviation Tolerance
  • MPt = Midpoint Deviation Tolerance
  • T2t = Tangent 2 Deviation Tolerance




Note that the two end points are also included in the tangent charts are reports (T1d in straight 1, and T2d in the last straight). They are an exception to the technical tangent definition given above because there is no bend attached to these points. But these points still have value in determining if the part is the correct shape, so it is convenient to include them in this chart and grid - even though they are not really tangents.

Midpoint deviations are always less than the highest corresponding tangent deviation, and higher than the lowest corresponding tangent deviation. They are included in traditional reports so that you can have three separate deviation tolerances in a straight. (T1-MP-T2)


Vtube-laser v2.7 tangentpoint deviations.png

The Same Data In Reports

The same tangent data can be shown in the reports like this.

Some customers prefer to modify the report to show only their critical data. For example, they may remove the midpoints or the end angles from the reports(which can be done by changing the report templates).

(For those with active VTube Software Maintenance Plans: We are happy to help you modify the report templates if you request it.)

Vtube-laser-tangent-report.png

How to Understand the Tangent Data

The image on the right shows the visual representation of the chart and report above. The deviations in the grid match the part in the image. The part is made transparent so that you can see the two centerlines inside the tube. (It's easy to make parts transparent by setting the transparency value about 0.75 inside the Parametric Tube control menu under Models.)

In the image below shows how the distance T1d is measured in the second straight:
Vtube-laser-t1d-illustrated.png


In this case, the T1d value is 0.9mm for straight 2.

Vtube-laser-t1d-mp-t2d-image1.png

How to Understand the End Point Deviations

Automatic Internal Trimming of End Points for Shape

Even though the end points are not tangents, we can still use them in the chart because they qualify the part the same way that tangent points do.

A key in understanding the T1d of straight one and the T2d of the last straight is to remember that the deviation is not the same as how long or short the straights are relative to the master tube shape. See the illustration on the right to understand why.

The MASTER to MEASURED end point deviation in the Tangent grid is 1.9mm. The measurement is the distance between the two lines at the corresponding end points - as if the MEASURED WERE TRIMMED.

(The Measured part is the pink part. The Master part is white.)

Vtube-laser-t1d-end1.png

Untrimmed End Points for Lengths

However, the end length is 90.2mm too long.

In this application, the customer bent the part 90mm too long on purpose in order to give the bend arm clamp die enough material on the first straight to grip.

Notice that, even though the part is significantly too long, the BEST FIT algorithm didn't use the actual measured end point in the alignment. The alignment was based on the trimmed point on the measured centerline that was nearest the master end point.

So, in this case the part shape in space is qualified - but it needs trimming by 90.2mm to also qualify the end length (another critical qualifier).

Vtube-laser-endlength.png


Typical Industry Tangent Point Tolerances

In working with thousands of customers over the past few decades, we've seen some trends in accepted envelope deviation tolerances. Here are what we commonly see:

Aerospace and Automative Fluid Lines

Diameter Range

Envelope Tolerance

12.7 mm (0.5 inch) diameter tubes or less

+/- 1 mm (0.039 inches)

Greater than 12.7 mm (0.5 inch)

+/- 2 mm (0.078 inches)

Automotive Exhaust Pipes

Diameter Range

Envelope Tolerance

50 mm to 76 mm

From +/- 2 mm to +/- 3 mm

76 mm to 102 mm

+/- 3 mm

Larger then 102 mm

+/- 3 mm or greater

Shipbuilding

Diameter Range

Envelope Tolerance

All Diameters

+/- 6 mm


HVAC

Diameter Range

Envelope Tolerance

All Diameters

+/- 2 to +/- 3 mm

Structural Tubes (Frames)

Diameter Range

Envelope Tolerance

All Diameters

+/- 2 to +/- 3 mm

Tighter Tolerances

Sometimes customers will required +/-0.75 mm - but this is very rare. We've never seen tube shapes that must be qualified with a deviation tolerance of less than +/- 0.75 mm.

Aerospace envelope tolerance.png
Exhaust envelope tolerance.png
Shipbuilding envelope tolerance.png