Difference between revisions of "Why VTube-LASER Reduces Data to Centerlines"

From ATTWiki
Jump to: navigation, search
(Answer)
(Answer)
Line 15: Line 15:
 
Before it reduces the straight to a centerline, VTube-LASER always calculates important metrics that help the user gauge how well the surface data fits to the centerline.  Not only does it qualify each cylinder straight fit to a centerline, but the process always gives a calculated diameter and the surface profile of the scan.
 
Before it reduces the straight to a centerline, VTube-LASER always calculates important metrics that help the user gauge how well the surface data fits to the centerline.  Not only does it qualify each cylinder straight fit to a centerline, but the process always gives a calculated diameter and the surface profile of the scan.
  
See [[VTube-LASER Wobble Deviation]].
+
See also [[VTube-LASER Wobble Deviation]]

Revision as of 15:44, 21 June 2022

  • Why does VTube-LASER reduce data to centerlines?

VTube-LASER AssemblyOverModel.png


Answer

VTube-LASER always automatically reduces each straight scanned to a centerline and then compares measured centerline data with the master.  This has been the method used in the tube-fabrication industry for decades because fabricated tube shapes are always defined using centerline geometry.  So, the goal of VTube-LASER is to always reduce a measured profile, whether it be cylinder or rectangular, to a centerline for qualification and bender data calculation.

Before it reduces the straight to a centerline, VTube-LASER always calculates important metrics that help the user gauge how well the surface data fits to the centerline. Not only does it qualify each cylinder straight fit to a centerline, but the process always gives a calculated diameter and the surface profile of the scan.

See also VTube-LASER Wobble Deviation