Difference between revisions of "VTube-LASER v2.1.2"

From ATTWiki
Jump to: navigation, search
(25px NEW: System Option Folder Icons)
(25px NEW: User Interface Changes)
Line 91: Line 91:
 
<td width=400>
 
<td width=400>
 
[[image:vtube-step-2.1_longprojectfilename.png|400px]]<br><br>
 
[[image:vtube-step-2.1_longprojectfilename.png|400px]]<br><br>
 +
</td>
 +
</tr>
 +
</table>
 +
 +
 +
===[[image:Check.jpg|25px]] NEW: System Option Folder Icons===
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=400>
 +
Each value field or menu in System Options now shows one of two folder icons next to each value or at the top of the menu.<br><br>
 +
These icons help you know where the value is stored.<br><br>
 +
 +
====[[image:vtube_folder_gear.png]] Gear Folder Icon====
 +
This folder indicates that the value is stored in the persistent configuration file.  This means that the value will be the same for all projects.
 +
 +
====[[image:vtube_folder_cubes.png]] Cubes Folder Icon====
 +
This folder indicates that the value is stored in the project file.  This means that the value can be unique for all projects.
 +
<br><br>
 +
</td>
 +
<td width=400>
 +
[[image:vtube-2.1_systemoption_foldericons.png|400px]]<br><br>
 
</td>
 
</td>
 
</tr>
 
</tr>

Revision as of 19:34, 14 June 2015

Vtube-laser logo.jpg

Revision 2.1.2

Vtube-laser 1.89 mainscreen.png



Check.jpg ENHANCED: Improved Graphics

  • Perspective projection is much improved.

  • Point labels drawing has improved logic and is much faster.

Vtube-laser 2.1.2 hvac with points.png

Check.jpg NEW: STEP Export is Faster for Large Models

The export speed on large models is now several times faster than in previous versions.

If you export STEP files, then this is an important update for you.

Vtube-step-2.1.2 stepexport.png

Check.jpg ENHANCED: Path Manager

The Path Manager is displayed whenever a file load or save operation is about to happen. It allows you to persistently save important paths to a list of paths for easy access in the future.

  • The Path Manager now shows the operation for which it as asking you to choose a path.

  • The Path Manager is now used for all Import and Export features.

  • New Path Manager buttons have been added for new features, and re-arranged for easier use.

VTube PathManager ActionContext.png
Vtube-step-2.1 PathManager Closeup.png

Check.jpg ENHANCED: Automatically Export STEP to SOLIDWORKS

Vtube-step-2.1 STEP Export SolidWorks Import.png

Now automatically send an exported STEP file to SolidWorks.

Vtube-step-2.1 STEP Export SolidWorks Import SolidWorksScreen.png


Check.jpg NEW: User Interface Changes

VTube Project Filename Box

  • There is a new current VTube Project filename box in the upper left corner. This box now shows the entire path of the current project file, so that there is no doubt about which file will be saved if you press the Save button. The text in this box can be selected and copied to the clipboard.

Pulldown Menu

  • The pulldown menu no longer stays open on the screen after a project load.

  • The pulldown menu now immediately updates the most recently used file list when you SAVE a new project.



Vtube-step-2.1 longprojectfilename.png


Check.jpg NEW: System Option Folder Icons

Each value field or menu in System Options now shows one of two folder icons next to each value or at the top of the menu.

These icons help you know where the value is stored.

Vtube folder gear.png Gear Folder Icon

This folder indicates that the value is stored in the persistent configuration file. This means that the value will be the same for all projects.

Vtube folder cubes.png Cubes Folder Icon

This folder indicates that the value is stored in the project file. This means that the value can be unique for all projects.

Vtube-2.1 systemoption foldericons.png

Check.jpg Other Changes

  • The VTube configuration file location was changed to the more standard "c:\ProgramData\VTube" location.

  • The installation performs a better job of setting up the configuration file location.

  • The Supravision network engine has been enhanced to handle data files that don't follow the Supravison spec perfectly.

  • We fixed a ball probe measurement issue where VTube would sometimes not always take in single points from the FARO driver. This issue created problems with measuring cut planes too. If you measured cut planes, and still couldn't get the cut plane to work properly, then it was probably due to this issue.


Other