Difference between revisions of "VTube-LASER v1.88"

From ATTWiki
Jump to: navigation, search
(25px ENHANCEMENT/FIX: VTube Ball Probe Logic for Newer FARO Drivers)
(25px Other Changes)
 
(22 intermediate revisions by one user not shown)
Line 26: Line 26:
 
<tr valign=top>
 
<tr valign=top>
 
<td width=400>
 
<td width=400>
In November of 2013, FARO drivers were updated to work with the new FARO Edge ES scanner.  This changed driver made changes to the way ball probe data was returned to VTube-LASER.  Sometimes ball probe data would not be returned at all.  At other times, it could be returned as data that was scanned in previous measures.<br><br>
+
In November of 2013, FARO drivers were updated to work with the new FARO Edge ES scanner.  This new driver made changes to the way ball probe data was returned to VTube-LASER.  Sometimes ball probe data would be returned as all zeros.  At other times, it could be returned as data that was scanned in previous measures.<br><br>
 
This update fixes the problem encountered with the new drivers.<br><br>
 
This update fixes the problem encountered with the new drivers.<br><br>
 
</td>
 
</td>
<td width=300>]
+
<td width=300>
 +
[[image:faro-probe-bluelight.png|200px]]
 
<br><br>
 
<br><br>
 
</td>
 
</td>
Line 35: Line 36:
 
</table>
 
</table>
  
<br><br>
+
===[[image:Check.jpg|25px]] ENHANCEMENT: More Robust UniScan Ball Probe Measurements===
 
+
===[[image:Check.jpg|25px]] NEW: Project Open QuickLoad Window===
+
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=400>
 
<td width=400>
  
An alternative QuickLoad window makes loading project files easier.  It increases the font size and reduces the number of clicks to get to a fileIt also has a search box that allows you to drill down in file searches quickly.
+
The measure method used to separate the UniScan ball probe measurements is improvedThis new method allows VTube to establish a more precise estimated starting vector for the internal cylinder fit math engine.<br><br>
<br><br>
+
[[image:vtube-1.87-quickload.png|500px]]<br><br>
+
</td>
+
<td width=300>
+
[[image:vtube-1.87-quickload-closeup.png|400px]]
+
</td>
+
</tr>
+
</table>
+
  
<br><br>
+
In this version, VTube-LASER will now assume that the last three points of a straight cylinder surface will be the furthest three points from the first points taken on the cylinder.<br><br>
 +
Follow these simple steps to use this new method:<br><br>
  
===[[image:Check.jpg|25px]] NEW: Cylinder Laser Spike Filter===
+
1 - Take three points at one end of the straight.<br>
<table cellpadding=10>
+
2 - Take three points at the other end of the straight.<br>
<tr valign=top>
+
3 - Press the red button.<br><br>
<td width=400>
+
  
This filter automatically removes spikes in cylindrical laser stripes.<br><br>
+
In UniScan mode, you can take as many points as you would like in between the two sets of three points.<br><br>
When measuring highly reflective tube, the points returned from the part of the diameter that is closest to the laser scanner on the FARO arm can spike away from the diameter.  This filter recognizes that possibility and removed any data that spikes away from the curve before it is given to the math engine.
+
<br><br>
+
[[image:vtube-laser-1.87_cylinderlaserspikefilter_menu.png|400px]]<br><br>
+
The filter options are in the bottom of the LASER tab in the Measure Setup menu.<br><br>
+
  
</td>
+
The minimum number of points in UniScan is 6.<br><br>
<td width=300>
+
[[image:vtube-laser-1.87_cylinderlaserspikefilter.png|400px]]<br><br>
+
</td>
+
</tr>
+
</table>
+
  
<br><br>
+
You can start at either end of the straight, as long as you finish at the other end of the same straight.
 
+
 
===[[image:Check.jpg|25px]] NEW: Automatic Remeasure At Measure Error===
+
<table cellpadding=10>
+
<tr valign=top>
+
<td width=400>
+
[[image:vtube-laser-1.87_automaticremeasure.png|400px]]<br><br>
+
Previous versions of VTube would always ask for the user to answer questions in a dialog when cylinder fit errors occur.  This new version of VTube can automatically ask the user to remeasure if the new switch in System Options:Measure 2 menu is switched on<br><br>
+
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:vtube-laser-1.87-automaticremeasure_guidebox.png|400px]]<br><br>
+
[[image:vtube-laser-1.88-uniscan_tactile.png|500px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
 
</table>
 
</table>
  
<br><br>
+
===[[image:Check.jpg|25px]] ENHANCEMENT: Ignore Red Button Press with ZERO Points===
 
+
===[[image:Check.jpg|25px]] ENHANCED: Added Radius Handling for Winton ECNC4 Benders===
+
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=400>
 
<td width=400>
  
[[image:winton_bender.jpg|300px]]<br>
+
When no points are present in the buffer, then the red button press will be ignored. The process will not be allowed to move forward.<br><br>
 
+
This avoids accidental red button presses.
The Winton ECNC4 data now handles the radius value during communications.
+
<br><br>
+
  
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:vtube-1.87-WintonECNC4_Radius.png|400px]]
 
 
</td>
 
</td>
 
</tr>
 
</tr>
 
</table>
 
</table>
 
<br><br>
 
  
 
===[[image:Check.jpg|25px]] Other Changes===
 
===[[image:Check.jpg|25px]] Other Changes===
Line 112: Line 81:
 
<tr valign=top>
 
<tr valign=top>
 
<td width=400>
 
<td width=400>
* The default path folders in the VTube-STEP Export windows are now properly stored for use next time.<br><br>
+
* The DRO now reports the number of STRIPES rather than the number of POINTs when in laser scanner modeThis lets you know exactly how many stripes have been scanned on any straight or end - in order to allow you to decide if enough stripes are in memory before pressing the red button for early completion.<br><br>
* A new Work Order field is added to the Part Setup menu.<br><br>
+
* The SEND SUCCESS window will now close if you exit the Bender Data Setup window.<br><br>
* The low level Benderlink setup grid (in Measure 2 of System Options) now stores bender names that were edited properly.<br><br>
+
* The SVNET Success window now automatically hides after a few seconds.<br><br>
+
* XYZ grids now update when part transformations occur.<br><br>
+
* Fixed initial project load stateVTube no longer asks for permission to clear the project if there is no change to memory after initial state.<br><br>
+
* VTube will now allow a MEASURED tube to be built to SolidWorks even when there is no Master XYZ data.<br><br>
+
* It is now possible to insert an XYZ row in the XYZ data if there are zero points.<br><br>
+
* The Point Count boxes now properly increment or decrement when an XYZ row is inserted or deleted.<br><br>
+
* VTube grids can now be selected and copied and output when the Lock Grids is active.<br><br>
+
  
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
 
+
[[image:vtube-laser-1.88-DRO_stripecount.png|500px]]
 
</td>
 
</td>
 
</tr>
 
</tr>

Latest revision as of 13:34, 18 March 2014

Vtube-laser logo.jpg

Revision 1.88


Vtube-laser 1.87 mainscreen.png




Check.jpg ENHANCEMENT and FIX: VTube Ball Probe Logic for Newer FARO Drivers

In November of 2013, FARO drivers were updated to work with the new FARO Edge ES scanner. This new driver made changes to the way ball probe data was returned to VTube-LASER. Sometimes ball probe data would be returned as all zeros. At other times, it could be returned as data that was scanned in previous measures.

This update fixes the problem encountered with the new drivers.

Faro-probe-bluelight.png

Check.jpg ENHANCEMENT: More Robust UniScan Ball Probe Measurements

The measure method used to separate the UniScan ball probe measurements is improved. This new method allows VTube to establish a more precise estimated starting vector for the internal cylinder fit math engine.

In this version, VTube-LASER will now assume that the last three points of a straight cylinder surface will be the furthest three points from the first points taken on the cylinder.

Follow these simple steps to use this new method:

1 - Take three points at one end of the straight.
2 - Take three points at the other end of the straight.
3 - Press the red button.

In UniScan mode, you can take as many points as you would like in between the two sets of three points.

The minimum number of points in UniScan is 6.

You can start at either end of the straight, as long as you finish at the other end of the same straight.

Vtube-laser-1.88-uniscan tactile.png

Check.jpg ENHANCEMENT: Ignore Red Button Press with ZERO Points

When no points are present in the buffer, then the red button press will be ignored. The process will not be allowed to move forward.

This avoids accidental red button presses.

Check.jpg Other Changes

  • The DRO now reports the number of STRIPES rather than the number of POINTs when in laser scanner mode. This lets you know exactly how many stripes have been scanned on any straight or end - in order to allow you to decide if enough stripes are in memory before pressing the red button for early completion.

  • The SEND SUCCESS window will now close if you exit the Bender Data Setup window.

Vtube-laser-1.88-DRO stripecount.png

Other