Difference between revisions of "VTube-LASER v1.81"

From ATTWiki
Jump to: navigation, search
(New Winton ECNC 4 Bender Correction)
(New Winton ECNC 4 Bender Setup and Correction)
 
(21 intermediate revisions by one user not shown)
Line 10: Line 10:
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:Vtube-laser_1.78.jpg|300px]]
+
[[image:Vtube-laser_1.81.jpg|300px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 18: Line 18:
  
 
* See [http://www.advancedtubular.com/customers/vtube VTube-LASER Customer Support Page] to download the latest version.
 
* See [http://www.advancedtubular.com/customers/vtube VTube-LASER Customer Support Page] to download the latest version.
<br><br>
+
<br>
 +
 
 +
===New Winton ECNC 4 Bender Setup and Correction===
 +
<table>
 +
<tr>
 +
<td width=300 valign=top>
 +
[[image:winton_logo.jpg|300px]]<br>
 +
[[image:winton_bender.jpg|300px]]<br>
 +
*This version can read and write ECNC version 4 offline program files.
 +
*Every value that can be setup in ECNC can also be setup in VTube-LASER.
 +
</td>
 +
<td valign=top>
 +
[[image:winton_ecnc_4_screen.jpg|400px]]<br>
 +
</td>
 +
</tr>
 +
</table>
 +
 
 +
<table>
 +
<tr>
 +
<td width=300 valign=top>
 +
[[image:vtubelaser_winton_ecnc_4_wholescreen2.jpg|400px]]
 +
<br>
 +
</td>
 +
<td valign="top">
 +
[[image:vtubelaser_winton_ecnc_4_screen.jpg|400px]]
 +
</td>
 +
</tr>
 +
</table>
  
 
===New Separate Report Template Setup for STEP and LASER===
 
===New Separate Report Template Setup for STEP and LASER===
Line 24: Line 51:
 
*Some report templates are only appropriate in LASER because LASER handles inspections.
 
*Some report templates are only appropriate in LASER because LASER handles inspections.
 
*Now the setup of each is stored separately.
 
*Now the setup of each is stored separately.
<br>
 
 
===New Winton ECNC 4 Bender Correction===
 
[[image:winton_ecnc_4_screen.jpg|400px]]<br>
 
*This version can read and write ECNC offline program files.
 
*Every value that can be setup in ECNC can also be setup in VTube-LASER.
 
 
<br>
 
<br>
  
Line 48: Line 69:
  
 
===New Inspection Grid Row Count Control===
 
===New Inspection Grid Row Count Control===
*VTube now controls the grid row count with the MASTER data row count rather than the MEASURED data row count.
+
*VTube now controls the INSPECTION grid row count with the MASTER data row count rather than the MEASURED data row count.
 
*This allows the grid to be populated even if the Measured data is cleared.
 
*This allows the grid to be populated even if the Measured data is cleared.
  

Latest revision as of 01:55, 19 January 2013

Vtube-laser logo.jpg

Revision 1.81

Vtube-laser 1.81.jpg



New Winton ECNC 4 Bender Setup and Correction

Winton logo.jpg
Winton bender.jpg

  • This version can read and write ECNC version 4 offline program files.
  • Every value that can be setup in ECNC can also be setup in VTube-LASER.

Winton ecnc 4 screen.jpg

Vtubelaser winton ecnc 4 wholescreen2.jpg

Vtubelaser winton ecnc 4 screen.jpg

New Separate Report Template Setup for STEP and LASER

  • Previous versions had identical setups in both modes.
  • Some report templates are only appropriate in LASER because LASER handles inspections.
  • Now the setup of each is stored separately.


New Supravision Project Wall Thickness Import/Output

  • Previous versions did not save the wall thickness
  • This version imports and exports the wall thickness value.


New Supravision Project Qualification Tolerance Envelopes Import/Export

  • This version now imports and exports these values:
    • Default Qualification Envelope Tolerance
    • A End Length Qualification Tolerance
    • B End Length Qualification Tolerance
    • A End Angle Qualification Tolerance
    • B End Angle Qualification Tolerance


New Inspection Grid Row Count Control

  • VTube now controls the INSPECTION grid row count with the MASTER data row count rather than the MEASURED data row count.
  • This allows the grid to be populated even if the Measured data is cleared.


Other Pages