Difference between revisions of "VTube-LASER v1.69"

From ATTWiki
Jump to: navigation, search
(25px ENHANCED: FARO Arm Measure Setup)
(25px ENHANCED: FARO Arm Measure Setup)
Line 16: Line 16:
  
 
===[[image:Check.jpg|25px]] ENHANCED: FARO Arm Measure Setup===
 
===[[image:Check.jpg|25px]] ENHANCED: FARO Arm Measure Setup===
[[image:vtube-laser_measure_setup_1_69.jpg|300px]]
 
  
 
<table cellpadding=10>
 
<table cellpadding=10>
Line 22: Line 21:
 
<td width=300>
 
<td width=300>
 
Measure Setup allows operators to control three more FARO windows.  It also shows all the current FARO arm and probe data in a grid below the setup buttons.
 
Measure Setup allows operators to control three more FARO windows.  It also shows all the current FARO arm and probe data in a grid below the setup buttons.
 +
<br><br>
 +
[[image:vtube-laser_measure_setup_1_69.jpg|300px]]
 
<br><br>
 
<br><br>
 
During calibration, Measure Setup has been changed to automatically re-display the Probe Menu after a calibration has been completed.  (This is the standard approach that operators expect during calibration.)
 
During calibration, Measure Setup has been changed to automatically re-display the Probe Menu after a calibration has been completed.  (This is the standard approach that operators expect during calibration.)

Revision as of 12:47, 3 September 2011

Vtube-laser logo.jpg

Revision 1.69

Back to VTube-LASER
Back to VTube-STEP

Vtube-laser 1 69.jpg

Contents


Check.jpg ENHANCED: FARO Arm Measure Setup

Measure Setup allows operators to control three more FARO windows. It also shows all the current FARO arm and probe data in a grid below the setup buttons.

Vtube-laser measure setup 1 69.jpg

During calibration, Measure Setup has been changed to automatically re-display the Probe Menu after a calibration has been completed. (This is the standard approach that operators expect during calibration.)

All forms of calibration choices in the Probe Menu are now enabled in this version.

Check.jpg ENHANCED: Arm Values Can Be Added to Reports

Many report value fields were added to the report logic. These fields can show the arm and probe calibration and accuracy values. Add these to any report or use them to create a custom report.

Vtube-laser report values 169.jpg

This allows the current state of the arm to be printed with the report - proving that the arm was calibrated during measurement.

Check.jpg NEW: Cut Plane Question

Vtube-laser cutplane question.jpg

VTube now asks if you intend to establish a cut plane immediately after the arm is connected to VTube-LASER.

Check.jpg NEW: VTube-LASER Programmer Mode

This new mode allows customers to purchase a license of VTube-LASER for programming VTube-LASER projects remotely where there is no need to connect to the FARO arm.

The license price for Programmer mode is significantly less expensive.

Vtube-laser programmer mode.jpg

Check.jpg Other Changes

  • VTube was adjusted to handle discovered Transfluid data file floating point requirements for diameter and radius. (To prevent load failure, Transfluid requires only two places beyond the decimal for these values - no more.)
  • VTube can now import a Transfluid file as MASTER data.
  • The arm as mouse speed is now controlled in the FARO hardware configuration menu - not in VTube-LASER System Options.



Check.jpg Issues with this version fixed in newer versions

  • No known issues



Other Pages

VTube-LASER Training Video - How to perform effective end scans.

Vtube-laser effective end scan video b.jpg