Many report value fields were added to reports that show the arm and probe calibration and accuracy values.  All of these values can be added to any report.
+
Many report value fields were added to the report logic.  These fields can show the arm and probe calibration and accuracy values.  Add these to any report or use them to create a custom report.
 
<br><br>
 
<br><br>
 
[[image:vtube-laser_report_values_169.jpg|300px]]
 
[[image:vtube-laser_report_values_169.jpg|300px]]

Revision as of 07:34, 3 September 2011

Vtube-laser logo.jpg

Revision 1.69

Back to VTube-LASER
Back to VTube-STEP

Vtube-laser 1 69.jpg

Contents


Check.jpg ENHANCED: Measure Setup

Vtube-laser measure setup 1 69.jpg

Measure Setup allows operators to control more FARO server menus, and shows all the current FARO arm and probe data in a grid below the setup buttons.

Check.jpg ENHANCED: Arm Values Can Be Added to Reports

Many report value fields were added to the report logic. These fields can show the arm and probe calibration and accuracy values. Add these to any report or use them to create a custom report.

Vtube-laser report values 169.jpg

This allows the current state of the arm to be printed with the report - proving that the arm was calibrated during measurement.

Check.jpg NEW: Cut Plane Question

Vtube-laser cutplane question.jpg

VTube now asks if you intend to establish a cut plane immediately after the arm is connected to VTube-LASER.

Check.jpg NEW: Added Tab Menus in the MASTER XYZ Menu

New tab menus with new options are now placed in separate tab menus in the Master XYZ menu.

Vtube-laser master xyz tabmenus setpoints.jpg
Vtube-laser master xyz tabmenus.jpg
Vtube-laser master xyz tabmenus splitbend.jpg




Check.jpg Other Changes

  • VTube was adjusted to handle discovered Transfluid data file floating point requirements for diameter and radius. (To prevent load failure, Transfluid requires only two places beyond the decimal for these values - no more.)
  • VTube can now import a Transfluid file as MASTER data.
  • The arm as mouse speed is now controlled in the FARO hardware configuration menu - not in VTube-LASER System Options.
  • Rotation corrections are always shift to the shortest side of the clock. For example +359 degree is reset to -1.0.
  • Now the tangent point/midpoint inspection grid is automatically set with the default tolerance when the grid grows.



Check.jpg Issues with this version fixed in newer versions

  • No known issues