Difference between revisions of "VTube-LASER v1.66"

From ATTWiki
Jump to: navigation, search
(25px ENHANCED: Measure Setup - Scan Rate Grid)
(25px Other Changes)
Line 67: Line 67:
 
<tr valign=top>
 
<tr valign=top>
 
<td width=400>
 
<td width=400>
* A bug was found and removed from the MOVE command.<br><br>
+
* Some Windows setups do not allow VTube-LASER to store data in the generic "ProgramData" folder, so we changed VTube so that it again uses the personal login folders to store program data.
* The System Options menu allows you to browse directly into support folders from inside VTube-LASER.<br><br>
+
* Many users never change their HTML templates to remove the temporary graphic logo, so the program is now installed with a blank white logo in that space.  This makes the reports more usable out of the box.
* VTube-LASER now uses the "All Users" or "ProgramData" folders to store configuration data for all users of the FARO computer. This solves problems for companies that require that each user login to Windows with their own permissions setup.<br><br>
+
* The Winton Machinery bender protocol was enhanced so that it automatically loads a template if no data is present in memory when an operator is ready to send data to the bender.<br><br>
+
 
+
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>

Revision as of 17:13, 27 May 2011

Vtube-laser logo.jpg

Revision 1.66

Back to VTube-LASER

Vtube-laser screen 1 66.jpg


Check.jpg NEW: Save Project Changes Dialog

Vtube-laser screen 1 66.jpg

VTube now tracks if the project has changed and needs to be saved before opening a new project or closing the software.

Vtube-saveprojectchangesdialog.jpg




Check.jpg NEW: In-Process Bend Correction

Vtube-laser 1 66 bendangletransfer.jpg

The new Bend Angle Transfer menu allows VTube to correct bends while still in the bender.

  • The bender forms a bend. This menu is loaded from the Data Transfer menu in VTube-LASER.
  • The clamp opens and the bender pauses.
  • The operator moves the FARO arm next to the bender and measures the single bend.
  • The bend angle is transferred to the Bend Angle Transfer menu.
  • The bend angle is sent to the bender control.
  • The bender control uses the data to close the clamp and adjust the bend angle.


The process is continued until the bend angle is within tolerance. The workflow is identical to measuring a single bend off the bender.

Vtube-laser 1 66 bendangletransfer wholescreen.jpg
Vtube-laser 1 66 bendangletransfer datatransfer.jpg







Check.jpg Other Changes

  • Some Windows setups do not allow VTube-LASER to store data in the generic "ProgramData" folder, so we changed VTube so that it again uses the personal login folders to store program data.
  • Many users never change their HTML templates to remove the temporary graphic logo, so the program is now installed with a blank white logo in that space. This makes the reports more usable out of the box.



Check.jpg Issues with this version fixed in newer versions

  • No known issues



Other Pages

VTube-LASER Training Video - How to perform effective end scans.

Vtube-laser effective end scan video b.jpg