Difference between revisions of "VTube-LASER v1.63"

From ATTWiki
Jump to: navigation, search
(25px NEW: Added LENGTH grid in the Inspection Menu)
(25px NEW: Multiple Point Qualification End Scan)
Line 68: Line 68:
 
<br><br>
 
<br><br>
  
===[[image:Check.jpg|25px]] NEW: Multiple Point Qualification End Scan===
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=200>
 
VTube-LASER now uses multiple points to qualify the end-scan.  This gives it better protection against outlier points.<br><br>
 
A new End-Scan Fit window gives information about how many points were used in the end-trim, and the span of all the point positions.  Higher point counts with lower spans indicate a better data set for end-trim.
 
</td>
 
<td width=300>
 
[[image:vtube-laser_endscan_fitwindow.jpg|300px]]<br><br>
 
</td>
 
</tr>
 
</table>
 
  
<br><br>
 
  
 
===[[image:Check.jpg|25px]] REPAIR: Diameter and Wall Detection for STEP Mode===
 
===[[image:Check.jpg|25px]] REPAIR: Diameter and Wall Detection for STEP Mode===

Revision as of 16:22, 1 April 2011

Vtube-laser logo.jpg

Revision 1.63

Back to VTube-LASER

Vtube-laser 1 63.jpg



Check.jpg NEW: Select and Configure any number of Reports

The Report menu was redesigned so that operators choose from a list of report templates to show any one of several reports.

  • Give each report template a name that is linked to an external report template file.

  • Change the list (Add, Delete, Move the template up or down).

  • Edit any template in the included Notepad++ editor (installs with v1.63).

  • Explore the folder that contains the templates.

  • There is no limitation on the number of templates allowed.

  • The report template setup is stored local to the computer (not in project files).

Vtube-laser report templates control.jpg




Check.jpg NEW: Added LENGTH grid in the Inspection Menu

The new Length grid shows the MASTER, MEASURED, and differences between the two.

Use these values to know how much to change the pre-bending material cut length.

The Crosscheck values were moved into this grid. (Crosscheck is a measure of the straight line from end A to end B.)

Vtube-laser length grid.jpg



Check.jpg Other Changes

  • Updated the graphics engine for faster redraws.

  • Added more report values - master length, measured length, delta between measured and master, bender setup LRA

  • Updated the manual and help file.




Check.jpg REPAIR: Diameter and Wall Detection for STEP Mode

See VTube-STEP v1.62 for details.

Vtube-step 1 62.jpg



Check.jpg Other Changes

  • The A End and B End OFFSETs other than ZERO caused a problem where end-scans would never be qualified. This has been resolved in this version.



Check.jpg Issues with this version fixed in newer versions

  • No known issues

Other Pages

VTube-LASER Training Video - How to perform effective end scans.

Vtube-laser effective end scan video b.jpg