Difference between revisions of "VTube-LASER v1.58"

From ATTWiki
Jump to: navigation, search
(25px NEW: Construct Tube in 3D Space)
(25px Issues with this version fixed in next version)
 
(23 intermediate revisions by one user not shown)
Line 13: Line 13:
  
 
__NOTOC__
 
__NOTOC__
 
 
 
===[[image:Check.jpg|25px]] NEW: Construct Tube in 3D Space===
 
===[[image:Check.jpg|25px]] NEW: Construct Tube in 3D Space===
  
Line 33: Line 31:
 
</tr>
 
</tr>
 
</table>
 
</table>
 
<br><br>
 
 
===[[image:Check.jpg|25px]] NEW: Transfer New Values in Supravision Protocol  ===
 
 
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
<td width=200>
+
<td width=500>
New values are included in Supravision file transfers and Supravision Network transfers from benders (imports/exports/bender corrections):
+
The new Construct Tube Control (shown above) allows you to point to any location in space to designate an end point or an intersection point.  It also allows you to increase the number of straights/points on-the-fly.  This allows operators to change the number of points at any time during the measurement process.
<br><br>
+
 
+
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
* Comment 1
 
* Comment 2
 
* Default Radius
 
* A End Offset
 
* B End Offset
 
* Tube Elongation Percentage
 
* Fixed Springback
 
* Proportional Springback
 
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 60: Line 43:
 
<br><br>
 
<br><br>
  
===[[image:Check.jpg|25px]] NEW: Recall the BENDER MASTER XYZ to Establish the VTube Master===
+
===[[image:Check.jpg|25px]] ENHANCED: Measure Tube Control - Decrease / Increase Button  ===
  
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=200>
 
<td width=200>
You can now ask the bender to give you the MASTER XYZ data if that data exists on the bender.
+
Operators can now increase or decrease the number of straights to measure in the tube on-the-fly if necessary.  The new Decrease/Increase buttons are inserted on the control.
 
<br><br>
 
<br><br>
The Bender Setup toolbar on the right has a new button that allows you to RECALL MASTER XYZ from a bender to create the MASTER data in VTube.
+
The control also shows the total number of straights being measured. So now the control will read, for example "Straight 1 of 5" - rather than just "Straight 1."
<br><br>
+
Before the transfer occurs, VTube will ask you to confirm that you mean to overwrite the MASTER data in VTube.<br><br>
+
If the incoming bender data does not have MASTER XYZ data, then VTube will warn you and stop the transfer.
+
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:vtube-laser_1_57_recallbendermaster.jpg|300px]].
+
[[image:vtube-laser_1_58_measuretube_control.jpg|300px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 80: Line 60:
 
<br><br>
 
<br><br>
  
===[[image:Check.jpg|25px]] ENHANCED: Bender Setup Redesigned===
+
===[[image:Check.jpg|25px]] NEW: Show SCANNED or CALCULATED Graphic Data Any Time===
  
[[image:vtube-laser_1_57_bendersetup_bendernumber.jpg|500px]]
 
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=200>
 
<td width=200>
The Bender Setup user interface menu was redesigned.
+
VTube now allows operators to show or hide the orange scanned points or the large orange calculated end and intersection points at any time.
<br><br>
+
* The bender number font size is larger.
+
* The toolbar on the right is more compact.
+
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
 +
[[image:vtube-laser_1_58_scanned_calculated_display.jpg|300px]].
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 98: Line 75:
 
<br><br>
 
<br><br>
  
===[[image:Check.jpg|25px]] ENHANCED: Negative Lengths or Bend Angles are ZEROED===
+
===[[image:Check.jpg|25px]] NEW: Auto Display SCANNED and CALCULATED===
  
[[image:vtube-laser_1_57_bendersetup_zeroedlength.jpg|500px]]
+
[[image:vtube-laser_1_58_autodisplay_scanned_calculated.jpg|500px]]
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
<td width=200>
+
<td width=500>
Bender Lengths and angles that calculate negative values are zeroed.
+
The Draw Options feature is new to Measure Setup.  You can select these two options if you want the SCANNED or the CALCULATED data to display or not during measurement.  If both features are unchecked, then the tube measurement shows now realtime graphics data during measurement - like other measurement software.  
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
Line 113: Line 90:
 
<br><br>
 
<br><br>
  
===[[image:Check.jpg|25px]] ENHANCED: Springback Compensation for Corrections  ===
+
===[[image:Check.jpg|25px]] ENHANCED: Highlighted Cylinder Fit Box During High Error===
  
 +
[[image:vtube-laser_1_58_cylinderfit_highlight.jpg|500px]]
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
<td width=200>
+
<td width=500>
The springback compensation values in the Bender Setup menu are now calculated based on the adjustment value alone.
+
The cylinder fit box highlights to YELLOW when it encounters a measurement in the tube that is outside the preprogrammed tolerance for cylinder fit.
<br>
+
* For example, if the adjustment value for a 90 degree bend is found to be +3 degrees, then the springback compensation added to the bend is calculated based on 3 degrees, not 93 degrees.
+
<br>
+
* The springback compensation works for both positive and negative adjustments.  A positive adjustment will add springback.  A negative adjustment will remove springback. 
+
<br>
+
* VTube will not use springback for small adjustment values.  The "Use springback compensation for bend adjustments greater than or equal to:" setting in the Bender Setup menu controls this.
+
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:vtube-laser_1_57_bendersetup_automatic_adjustment_springback.jpg|300px]]<Br><br>
 
[[image:vtube-laser_1_57_bendersetup_automatic_adjustment_springback_limit.jpg|300px]].
 
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 135: Line 105:
 
<br><br>
 
<br><br>
  
===[[image:Check.jpg|25px]] NEW: Transfer Master LRA to Setup LRA with Springback Compensation  ===
+
===[[image:Check.jpg|25px]] Issues with this version fixed in next version===
  
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
<td width=200>
+
<td width=500>
When transferring data from the VTube MASTER LRA to the BENDER SETUP LRA, automatic springback compensation is automatically applied if the springback values are non-zero.</td>
+
* When using tactile end-measure and laser straight measure in the same tube, the tactile measurements would never be offset by the ball radius. Don't mix tactile and laser measurements in this version or previous versions of VTube.
<td width=300>
+
* See [[VTube-LASER v1.59]]
[[image:vtube-laser_1_57_bendersetup_master2setup_autospringback.jpg|300px]].
+
</td>
+
</tr>
+
</table>
+
 
+
<br><br>
+
 
+
===[[image:Check.jpg|25px]] NEW: Part Name in Toolbar  ===
+
[[image:vtube-laser_1_57_toolbar_filename.jpg|500px]]
+
<table cellpadding=10>
+
<tr valign=top>
+
<td width=200>
+
The current part name is now displayed in the toolbar below the VTube-LASER logo.
+
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
Line 160: Line 117:
 
</tr>
 
</tr>
 
</table>
 
</table>
<br><br>
 
 
===[[image:Check.jpg|25px]] NEW- Springback Values Transfer from Overbend  ===
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=200>
 
VTube-LASER can now receive springback data from Overbend with the press of a single button in the Overbend Calculator.<br><br>
 
</td>
 
<td>
 
[[image:vtube-laser_1_57_overbend_sendvaluestovtube.jpg|300px]]<br><br>
 
</td>
 
</tr>
 
</table>
 
[[image:vtube-laser_1_57_overbend_transfer.jpg|500px]]
 
<br><br>
 
 
===[[image:Check.jpg|25px]] ENHANCED - Other Changes  ===
 
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=200>
 
* Added high precision angular decimal places value in System Option/Math
 
<br><br>
 
* Made Comments to display after the file has loaded and the graphic is displayed on the screen.
 
<br><br>
 
* The BEST FIT alignment procedure is fine tuned to run about 6 times faster than in previous versions with no loss of accuracy.
 
<br><br>
 
* Improvements/fixes to Supravision RECALL procedures.
 
 
[[image:vtube-laser_1_57_benderrecall.jpg|200px]]<br><br>
 
</td>
 
<td>
 
[[image:vtube-laser_1_57_highprec_angledecimalplaces.jpg|300px]]<br><br>
 
[[image:vtube-laser_1_57_partcomments.jpg|300px]]<br><br>
 
[[image:vtube-laser_1_57_bestfit_image.jpg|300px]]<br><br>
 
 
</td>
 
</tr>
 
</table>
 
 
 
<br><br>
 
  
 
=Other Pages=
 
=Other Pages=
 
*Back to [[VTube-LASER]]
 
*Back to [[VTube-LASER]]

Latest revision as of 22:14, 21 February 2011

Vtube-laser logo.jpg

Revision 1.58

Back to VTube-LASER

Vtube-laser 1 58.jpg


Check.jpg NEW: Construct Tube in 3D Space

Tube shapes can now be constructed by pointing the arm ball probe to the end points and intersection points.

This feature allows you to route a tube in 3D space.

The feature is used by our customers to construct tube routes in a vehicle's engine compartment or under the car on a lift.

Vtube-laser 1 58 constructtube control.jpg

Vtube-laser 1 58 constructtube closeup.jpg

Vtube-laser 1 58 constructtube.jpg

The new Construct Tube Control (shown above) allows you to point to any location in space to designate an end point or an intersection point. It also allows you to increase the number of straights/points on-the-fly. This allows operators to change the number of points at any time during the measurement process.



Check.jpg ENHANCED: Measure Tube Control - Decrease / Increase Button

Operators can now increase or decrease the number of straights to measure in the tube on-the-fly if necessary. The new Decrease/Increase buttons are inserted on the control.

The control also shows the total number of straights being measured. So now the control will read, for example "Straight 1 of 5" - rather than just "Straight 1."

Vtube-laser 1 58 measuretube control.jpg



Check.jpg NEW: Show SCANNED or CALCULATED Graphic Data Any Time

VTube now allows operators to show or hide the orange scanned points or the large orange calculated end and intersection points at any time.

Vtube-laser 1 58 scanned calculated display.jpg.



Check.jpg NEW: Auto Display SCANNED and CALCULATED

Vtube-laser 1 58 autodisplay scanned calculated.jpg

The Draw Options feature is new to Measure Setup. You can select these two options if you want the SCANNED or the CALCULATED data to display or not during measurement. If both features are unchecked, then the tube measurement shows now realtime graphics data during measurement - like other measurement software.



Check.jpg ENHANCED: Highlighted Cylinder Fit Box During High Error

Vtube-laser 1 58 cylinderfit highlight.jpg

The cylinder fit box highlights to YELLOW when it encounters a measurement in the tube that is outside the preprogrammed tolerance for cylinder fit.



Check.jpg Issues with this version fixed in next version

  • When using tactile end-measure and laser straight measure in the same tube, the tactile measurements would never be offset by the ball radius. Don't mix tactile and laser measurements in this version or previous versions of VTube.
  • See VTube-LASER v1.59

Other Pages