Difference between revisions of "VTube-LASER v1.55"

From ATTWiki
Jump to: navigation, search
(25px NEW - Realtime Calculation of Intersection)
(25px FIX - Measure Tube XYZ Data Build)
 
(11 intermediate revisions by one user not shown)
Line 21: Line 21:
 
Since radius sections are often highly distorted with ovality and changing radius values along the bend, this new radius scan-segment measurement method allows for more accurate averaging of radius measurement for reverse-engineering of radius values by allowing users to scan as many as 10 arc segments if necessary for better averaging of radius values.
 
Since radius sections are often highly distorted with ovality and changing radius values along the bend, this new radius scan-segment measurement method allows for more accurate averaging of radius measurement for reverse-engineering of radius values by allowing users to scan as many as 10 arc segments if necessary for better averaging of radius values.
 
<br><br>
 
<br><br>
The Set Segment Scan Count box (see below) allows you to enter from 3 to 10 segments to measure per arc.
+
The new Set Segment Scan Count box allows you to enter from 3 to 10 segments to measure per arc. (Also see the enhanced Measure Process menu below.)
 
<br><br>
 
<br><br>
  
Line 60: Line 60:
 
</tr>
 
</tr>
 
</table>
 
</table>
<br><br>
 
  
  
 
+
===[[image:Check.jpg|25px]] FIX - Measure Tube XYZ Data Build ===
===[[image:Check.jpg|25px]] NEW - Realtime Calculation of Intersection Error ===
+
  
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=200>
 
<td width=200>
Each point is checked for a Maximum Intersection Error which is set in the Measuring 2 tab of the System Options menu. The default tolerance is 2mm, or 0.078 inches.
+
This version fixes a bug found in version 1.54 where the Measured XYZ data may not update after a measure.<br><br>
<br><br>
+
If an intersection error calculates beyond the tolerance, then VTube stops and warns the operator of a potential problem, then allows him to remeasure or continue to the next straight.
+
</td>
+
<td>
+
[[image:vtube-laser_intersection_error_idialog.jpg|300px]]
+
</td>
+
</tr>
+
</table>
+
<br><br>
+
  
===[[image:Check.jpg|25px]] NEW - Code Signing of VTube.exe  ===
+
Please be sure to use this version rather than v1.54.
 
+
<table cellpadding=10>
+
<tr valign=top>
+
<td width=200>
+
The VTube program is now code signed in order to comply with the Microsoft Authenticode requirements.
+
 
<br><br>
 
<br><br>
*Ensures authenticity - users that they know where the code came from
 
*Ensures integrity - verifies that code has not been tampered with since publication
 
*Reduces error messages and security warnings on download and installation on Windows Vista and Windows 7 computers
 
 
</td>
 
</td>
 
<td>
 
<td>
[[image:vtube-laser_codesigned.jpg|300px]]
 
 
</td>
 
</td>
 
</tr>
 
</tr>
 
</table>
 
</table>
<br><br>
 
  
===[[image:Check.jpg|25px]] NEW - Verified Bluetooth Compatible ===
+
===[[image:Check.jpg|25px]] ENHANCED - Best Fit Alignment Mathematics ===
  
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=200>
 
<td width=200>
VTube-LASER is verified to work with the FARO ScanArm Bluetooth connection.  This allows connection to the FARO arms within 30 feet of the VTube-LASER computer without cables.
+
New features were added to prevent unnecessary errors/warnings from displaying for parts that align too closely with the master part.
</td>
+
<td>
+
[[image:vtube-laser_bluetooth.jpg|300px]]<br>
+
[[image:vtube-laser_systemtray_bluetooth.jpg|300px]]
+
</td>
+
</tr>
+
</table>
+
<br><br>
+
 
+
===[[image:Check.jpg|25px]] ENHANCED - VTube-LASER Setup Files Include the FARO USB Setups  ===
+
 
+
<table cellpadding=10>
+
<tr valign=top>
+
<td width=200>
+
The VTube-LASER installation setup now includes the FARO USB drivers for either 32 or 64 bit computers.</td>
+
<td>
+
[[image:usb_connector.jpg|300px]]
+
</td>
+
</tr>
+
</table>
+
 
+
===[[image:Check.jpg|25px]] NEW - PDF Printer Driver Setup Included in Installation  ===
+
 
+
<table cellpadding=10>
+
<tr valign=top>
+
 
+
<td width=200>
+
Now every VTube-LASER installation can also install a PDF printer driver for easy output of inspection reports in the PDF format.  This lets operators create historical fixed reports with static date/time for a record of qualification of the tube shape.
+
 
<br><br>
 
<br><br>
The two programs installed are the CutePDF Writer printer driver and the GPL Ghostscript program - which is required by the CutePDF Writer print driver to operate.
 
 
</td>
 
</td>
 
<td>
 
<td>
[[image:gpl_ghostscript_installation.jpg|300px]]<br>
 
[[image:cute_pdf_installation.jpg|300px]]
 
 
</td>
 
</td>
 
</tr>
 
</tr>

Latest revision as of 02:53, 5 January 2011

Vtube-laser logo.jpg

Revision 1.55

Back to VTube-LASER

Vtube-laser screen 1 54.jpg


Check.jpg NEW: Radius Segment Scan Method

Since radius sections are often highly distorted with ovality and changing radius values along the bend, this new radius scan-segment measurement method allows for more accurate averaging of radius measurement for reverse-engineering of radius values by allowing users to scan as many as 10 arc segments if necessary for better averaging of radius values.

The new Set Segment Scan Count box allows you to enter from 3 to 10 segments to measure per arc. (Also see the enhanced Measure Process menu below.)

Vtube-laser radius segment measurement graphic.jpg

Vtube-laser radius segment scan count.jpg

Check.jpg ENHANCED - Measure Process Menu

The enhanced Measure Process menu is reorganized. The menu includes the new Straight Count box - which was moved from the Measure Setup menu.

The menu also includes a new field for the new Radius Segment Scan - segment count.

Vtube-laser measureprocess v1 55.jpg



Check.jpg ENHANCED - Measure Setup Menu

The Measure Setup program is condensed because the Straight Count setting has been moved to the Measure Process menu for consistency.

Vtube-laser measuresetup v1 55.jpg


Check.jpg FIX - Measure Tube XYZ Data Build

This version fixes a bug found in version 1.54 where the Measured XYZ data may not update after a measure.

Please be sure to use this version rather than v1.54.

Check.jpg ENHANCED - Best Fit Alignment Mathematics

New features were added to prevent unnecessary errors/warnings from displaying for parts that align too closely with the master part.

Other Pages