Difference between revisions of "VTube-LASER and VTube-STEP - How to Reset the XYZ Radii to the Default Radius in the Part Setup Menu"

From ATTWiki
Jump to: navigation, search
(STEP 3 - PRESS the "Resynchronize Radii to Default" BUTTON)
 
(One intermediate revision by one user not shown)
Line 15: Line 15:
  
 
* Back to [[VTube-LASER]]
 
* Back to [[VTube-LASER]]
* Back to [[VTube-STEP]]
+
* Back to [[VTube-STEP]]<br><br>
 
__TOC__
 
__TOC__
  
Line 81: Line 81:
 
<br><br><br>
 
<br><br><br>
  
=[[image:vtube-laser_logo_1.96.png|200px]] How to SEND CORRECTION Data to the HERBER Control from VTube-LASER=
 
 
===STEP 1 - Bend the Tube===
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=300>
 
Bend the tube in the HERBER bender.<br><br>
 
<td>
 
[[image:HERBER Control Station.png|200px]] [[image:herber bender large tube bending.png|400px]]
 
</td>
 
</tr>
 
</table>
 
 
===STEP 2 - Measure the tube with VTube-LASER===
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=300>
 
Measure and align the tube to determine if it qualifies by falling within the envelope tolerance for the tube shape. <br><br>
 
In the screen shot on the right, the red on the top left shows that the first END "A" LENGTH is out of tolerance.<br><br>
 
Also, the red cells in the tangent point grid show that the measured tube centerline shape is out-of-tolerance.<br><br>
 
Also - VTube is very visual. The solid model on the right shows exactly where the part is out is exceeding the tolerance.
 
Click on the image to zoom in to see the values.
 
 
<td>
 
[[image:Vtube-imc screen romer arm.png|500px]]<br><br>
 
[[image:VTube-LASER UNISON Inspection Result.png|400px]]
 
</td>
 
</tr>
 
</table>
 
 
===STEP 3 - Enter BENDER SETUP===
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=300>
 
Click on the BENDER SETUP button in the Navigation Pane. <br><br>
 
 
<td>
 
[[image:VTube-LASER UNISON Click on Bender Setup.png|400px]]<br><br>
 
</td>
 
</tr>
 
</table>
 
 
===STEP 4 - Choose the BENDER NUMBER===
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=300>
 
Set the correct bender number at the top of the window.<br><br>
 
You can select up to 100 different benders.<br><br>
 
The Bender Protocol should say "HERBER MES". (This assumes that you have already configured VTube's Benderlink in the Systems Options as described in the previous section.)
 
</td>
 
<td>
 
[[image:vtl_v2.9.10_bendersetup_choosebender_herber.png|400px]]
 
</td>
 
</tr>
 
</table>
 
 
===STEP 5 - COPY the Data from VTube-LASER's Main Memory===
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=300>
 
If this is the first correction, then the Bender Setup screen may show no data.  If this is the case, then it is necessary to update the Bender Setup screen from VTube-LASER's main memory like this:<br><br>
 
* Press "Setup this Window".
 
* Press "Copy Master LRA to Setup LRA".
 
</td>
 
<td>
 
[[image:vtl_v2.9.10_herber_copy_master_lra_to_setup_lra.png|400px]]<br><br>
 
</td>
 
</tr>
 
</table>
 
 
 
===STEP 6 - OPTIONAL STEP - You Can Manually Change the ADJUSTMENT Values===
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=300>
 
You can manually change the ADJUSTMENT values before sending corrections if you want to. Some users like to set the first and last Length adjustment to zero in order to keep the start position of the carriage in the same place - for when they have extra length on the ends.<br><br>
 
If you want to, it is even possible to invert the rotation direction to keep the tube from hitting the bender during rotations.
 
<td>
 
[[image:vtl_v2.9.10 HERBER Manually Adjust Correction Values.png|400px]]<br><br>
 
</td>
 
</tr>
 
</table>
 
 
===STEP 7 - Send Corrections to the HERBER===
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=300>
 
Press "Auto SEND Bender CORRECTIONS".  VTube-LASER will let you select a path, then save a MES file to that path.
 
<td>
 
[[image:vtl_v2.9.10_herber_send_corrections.png|400px]]<br><br>
 
</td>
 
</tr>
 
</table>
 
 
===STEP 8 - The SEND to BENDER Complete Window===
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=300>
 
A window should appear for a few seconds indicating that the Send to the Bender is complete.<br><br>
 
You can allow this window to close on its own in a few seconds, or press the close button to close it immediately.
 
<td>
 
[[image:vtl_v2.9.10 HERBER Send Adjusted Complete.png|400px]]<br><br>
 
</td>
 
</tr>
 
</table>
 
 
===STEP 9 - IMPORT the Correction Data at the HERBER Control===
 
 
 
<table width=900>
 
<tr valign=top>
 
<td width=500>
 
Move to the HERBER control and follow these steps:<br><br>
 
* Click on “Read measurement from machine” in the Communications menu.<br><br>
 
* Select your measuring system (VTube).
 
</td>
 
<td>
 
[[image:HERBERScreen1.png|500px]]<br>
 
</td>
 
</tr>
 
 
<tr valign=top>
 
<td width=500>
 
* Select the .MES file VTube-LASER just created. When you click OK, the HERBER software will ask if you want to delete the MES file after importing.<br><br>
 
* To apply all corrections from the mes file, click on “Save all measurements” and continue bending. You are not required to stop the machine to do this. The HERBER cell allows for correction in an automated production cell in realtime. The corrections will be applied for the next part bent.
 
 
</td>
 
<td>
 
[[image:HERBERScreen2.png|500px]]<br>
 
 
</td>
 
</tr>
 
 
<tr valign=top>
 
<td width=500>
 
* It is also possible to delete or save individual correction values by marking a bend and opening the measure tab.
 
 
</td>
 
<td>
 
[[image:HERBERScreen3.png|500px]]<br>
 
 
</td>
 
</tr>
 
 
</table>
 
 
===STEP 10 - REPEAT STEPS 1 THROUGH 9===
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=300>
 
Bend the corrected tube starting in Step 1, then measure it again (Step 2) and follow the rest of the steps until the part is within tolerance.
 
<td>
 
[[image:HERBER Control Station.png|200px]] [[image:herber bender large tube bending.png|400px]]
 
</td>
 
</tr>
 
</table>
 
  
 
==Other Pages==
 
==Other Pages==
 
* See [[VTube-LASER]]
 
* See [[VTube-LASER]]
 
* See [[VTube-STEP]]
 
* See [[VTube-STEP]]
* See [[UNISON]] for information on UNISON benders
 

Latest revision as of 20:30, 5 July 2018

Vtube-step logo 2.png Vtube-laser logo 1.96.png

This article shows how to quickly propagate radii values to other parts of VTube-LASER and VTube-STEP using the DEFAULT RADIUS value.

These steps work the same in both LASER and STEP modes.

Contents


STEP 1 - Enter the DEFAULT RADIUS

The only purpose of the Default Radius value is to make setting multiple XYZ and LRA data rows easier. Think of the default radius as the radius that is used most often for any given tube. Enter that value in the Part Setup menu, then allow it to speed up entry in other menus.

You can also use the Default Radius to quickly change all the bend radii values in the tube shape at any date in the future. In this example, we've entered 3.5 inches in the row 26 Default Radius.

Vtube PartSetup Row26 DefaultRadius STEP.png

STEP 2 - RADII TAB MENU

Enter the XYZ menu. This is the Parametric Tube Data menu in STEP mode, and the either the MASTER TUBE or MEASURED TUBE menus in VTube-LASER mode.

Click on the Radii tab menu.



Vtube v2.9.10 radii tab menu.png

STEP 3 - PRESS the "Resynchronize Radii to Default" BUTTON

Press the button to change all the radii.

Vts v2.9.10 resync radii button.png





STEP 4 - PRESS the "F2" BUTTON to REFRESH THE PARAMETRICS

Pressing F2 will refresh the parametric model and show the radius change like this.

Vts v2.9.10 refreshF2 radiuschange.png





Other Pages