Difference between revisions of "VTube-LASER Data Handling for Premier, EL2000, and Velog Controls"
(Created page with "=VTube-LASER to Premier, EL2000, Velog Data Transfer= <table> <tr> <td width=300 valign="top"> VTube-LASER can communicate with legacy Eaton Leonard benders through current l...") |
|||
(15 intermediate revisions by one user not shown) | |||
Line 1: | Line 1: | ||
− | + | This page covers how VTube-LASER handles Legacy Eaton Leonard data internally. For a separate tutorial on '''communications''', see [[VTube-LASER to Eaton Leonard Premier Communications Tutorial]].<br><br><br> | |
+ | |||
+ | ==STORAGE of ALL Legacy Eaton Leonard Data in PROJECT FILES== | ||
<table> | <table> | ||
<tr> | <tr> | ||
<td width=300 valign="top"> | <td width=300 valign="top"> | ||
− | |||
VTube-LASER will allow for the complete setup of all bender and setup data that can be stored in a Premier, EL2000, or Velog control.<br><br> | VTube-LASER will allow for the complete setup of all bender and setup data that can be stored in a Premier, EL2000, or Velog control.<br><br> | ||
The Eaton Leonard values are never lost because this data is now stored inside each VTube-LASER project file. <br><br> | The Eaton Leonard values are never lost because this data is now stored inside each VTube-LASER project file. <br><br> | ||
Line 37: | Line 38: | ||
− | |||
<br> | <br> | ||
<br> | <br> | ||
Line 51: | Line 51: | ||
</tr> | </tr> | ||
</table> | </table> | ||
+ | |||
+ | ==Other Pages== | ||
+ | |||
+ | * See also [[VTube-LASER]] | ||
+ | * See [[Eaton Leonard]] | ||
+ | * See [[Benderlink Ethernet Module]]s | ||
+ | * See [[VTube-LASER to Eaton Leonard Premier Communications Tutorial]] |
Latest revision as of 17:09, 2 December 2016
This page covers how VTube-LASER handles Legacy Eaton Leonard data internally. For a separate tutorial on communications, see VTube-LASER to Eaton Leonard Premier Communications Tutorial.
Contents |
STORAGE of ALL Legacy Eaton Leonard Data in PROJECT FILES
VTube-LASER will allow for the complete setup of all bender and setup data that can be stored in a Premier, EL2000, or Velog control. YBC Velocity, Function, Stop, and C Last IncludedThis data includes all the part setup data and all the data that is included in each YBC row, including these data columns:
YBC Data Automatically Synchronized with Blue Column LRA Data in the Parent WindowThe YBC data in this Eaton Leonard Setup window is always synchronized with the blue columns in the parent VTube Bender Setup window. Use Either Inches or MillimetersThe screen allows you to switch between Inches and Millimeters and back again with the press of a single button.
|