+ | <h3>This feature is considered obsolete and was removed as of Version 2.9 - November 1, 2017</h3> | ||
=== How the Tolerance Works === | === How the Tolerance Works === | ||
Line 17: | Line 19: | ||
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
− | <td width= | + | <td width=300> |
− | + | <br><br> | |
− | The End Scan tolerance allows VTube-LASER to control which points are accepted as potential end-scan points based on how far the points are from the A-End and B-End Diameter values. | + | The End Scan tolerance allows VTube-LASER to control which points are accepted as potential end-scan points based on how far the points are from the A-End and B-End Diameter values.<br><br> |
− | The image | + | The image illustrates a tolerance of 1 inch. Any end scan points within that region will be qualified (the orange points).The red points are outside the tolerance, so they are rejected.<br><br> |
− | < | + | |
+ | The tolerance is measured from the out diameter in both directions - both positive (away from the centerline) and negative (toward the centerline).<br><br></td> | ||
+ | <td width=500> | ||
+ | [[image:VTube-laser-EndScanDiameterQualificationToleranceIllustration.png|600px]] | ||
</td> | </td> | ||
</tr> | </tr> | ||
Line 35: | Line 39: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=500> | <td width=500> | ||
− | You can set the tolerance in two places in VTube. One is in the System Options / Measure 2 menu.</td> | + | You can set the tolerance in two places in VTube. One place is in the System Options / Measure 2 menu.</td> |
<td width=300> | <td width=300> | ||
[[image:VTube-LASER-Measure2-EndScanDiameterQualificationTolerance.png|300px]] | [[image:VTube-LASER-Measure2-EndScanDiameterQualificationTolerance.png|300px]] | ||
Line 45: | Line 49: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=500> | <td width=500> | ||
− | The second place to edit the value is in the Measure Setup menu's "Other" tab menu.</td> | + | The second place to edit the value is in the VTube-LASER Measure Setup menu's "Other" tab menu.</td> |
<td width=300> | <td width=300> | ||
[[image:VTube-LASER-MeasureSetup-EndScanDiameterQualificationTolerance.png|300px]] | [[image:VTube-LASER-MeasureSetup-EndScanDiameterQualificationTolerance.png|300px]] | ||
Line 52: | Line 56: | ||
</table> | </table> | ||
− | === | + | ===Choosing Values=== |
Line 58: | Line 62: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=500> | <td width=500> | ||
− | * | + | *A tight qualification is 0.039 inches (1 millimeter). It is much more challenging to measure the end scan with a tight tolerance. Keep in mind that tube deformation will make tight tolerance end scans more challenging.<br><br> |
+ | |||
+ | *A much easier / quicker qualification is to increase the value to much high number - like 1 inch (25.4 millimeters).<br><br> | ||
+ | *Some customers use large values (like 10 inches) to avoid this qualification from occurring completely - and making end scans much easier.<br><br> | ||
+ | |||
+ | |||
+ | |||
+ | </td> | ||
+ | <td width=300> | ||
+ | |||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | ===Set the Default=== | ||
+ | |||
+ | |||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=500> | ||
+ | Set the default value by clearing the VTube project, then changing the value, then saving the setup to the default file in the System Options - Project Setup menu.<br> | ||
+ | |||
</td> | </td> | ||
<td width=300> | <td width=300> |
Latest revision as of 04:35, 1 November 2017
End Scan Diameter Qualification Tolerance
|
This feature is considered obsolete and was removed as of Version 2.9 - November 1, 2017
How the Tolerance Works
The End Scan tolerance allows VTube-LASER to control which points are accepted as potential end-scan points based on how far the points are from the A-End and B-End Diameter values. The image illustrates a tolerance of 1 inch. Any end scan points within that region will be qualified (the orange points).The red points are outside the tolerance, so they are rejected. |
How to Set the Tolerance
You can set the tolerance in two places in VTube. One place is in the System Options / Measure 2 menu. |
The second place to edit the value is in the VTube-LASER Measure Setup menu's "Other" tab menu. |
Choosing Values
|
Set the Default
Set the default value by clearing the VTube project, then changing the value, then saving the setup to the default file in the System Options - Project Setup menu. |
Other Pages
- Back to VTube-LASER