Difference between revisions of "VTube-LASER - End Scan Diameter Qualification Tolerance"

From ATTWiki
Jump to: navigation, search
(How the Tolerance Works)
 
(18 intermediate revisions by one user not shown)
Line 12: Line 12:
 
</table>
 
</table>
 
__NOTOC__
 
__NOTOC__
 +
 +
<h3>This feature is considered obsolete and was removed as of Version 2.9 - November 1, 2017</h3>
  
 
=== How the Tolerance Works ===
 
=== How the Tolerance Works ===
Line 17: Line 19:
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
<td width=500>
+
<td width=300>
  
[[image:VTube-laser-EndScanDiameterQualificationToleranceIllustration.png|500px]]<br><br>
+
<br><br>
  
The End Scan tolerance allows VTube-LASER to control which points are accepted as potential end-scan points based on how far the points are from the A-End and B-End Diameter values.
+
The End Scan tolerance allows VTube-LASER to control which points are accepted as potential end-scan points based on how far the points are from the A-End and B-End Diameter values.<br><br>
  
The image above illustrates a tolerance of 10 millimeters.  Any end scan points within that region will be qualified.  See the orange points in image. The red points are outside the tolerance, so they are rejected.</td>
+
The image illustrates a tolerance of 1 inch.  Any end scan points within that region will be qualified (the orange points).The red points are outside the tolerance, so they are rejected.<br><br>
<td width=300>
+
  
[[image:VTube-LASER-Measure2-EndScanDiameterQualificationTolerance.png|300px]]
+
The tolerance is measured from the out diameter in both directions - both positive (away from the centerline) and negative (toward the centerline).<br><br></td>
 +
<td width=500>
 +
[[image:VTube-laser-EndScanDiameterQualificationToleranceIllustration.png|600px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
 
</table>
 
</table>
 
  
 
=== How to Set the Tolerance ===
 
=== How to Set the Tolerance ===
Line 37: Line 39:
 
<tr valign=top>
 
<tr valign=top>
 
<td width=500>
 
<td width=500>
You can set the tolerance in two places in VTube.  One is in the System Options / Measure 2 menu.</td>
+
You can set the tolerance in two places in VTube.  One place is in the System Options / Measure 2 menu.</td>
 
<td width=300>
 
<td width=300>
 
[[image:VTube-LASER-Measure2-EndScanDiameterQualificationTolerance.png|300px]]
 
[[image:VTube-LASER-Measure2-EndScanDiameterQualificationTolerance.png|300px]]
Line 47: Line 49:
 
<tr valign=top>
 
<tr valign=top>
 
<td width=500>
 
<td width=500>
The second place to edit the value is in the Measure Setup menu's "Other" tab menu.</td>
+
The second place to edit the value is in the VTube-LASER Measure Setup menu's "Other" tab menu.</td>
 
<td width=300>
 
<td width=300>
 
[[image:VTube-LASER-MeasureSetup-EndScanDiameterQualificationTolerance.png|300px]]
 
[[image:VTube-LASER-MeasureSetup-EndScanDiameterQualificationTolerance.png|300px]]
Line 54: Line 56:
 
</table>
 
</table>
  
===Other End-Scan Information===
+
===Choosing Values===
  
  
Line 60: Line 62:
 
<tr valign=top>
 
<tr valign=top>
 
<td width=500>
 
<td width=500>
* [[VTube-LASER - End Scan Diameter Qualification Tolerance]]
+
*A tight qualification is 0.039 inches (1 millimeter).  It is much more challenging to measure the end scan with a tight tolerance.  Keep in mind that tube deformation will make tight tolerance end scans more challenging.<br><br>
 +
 
 +
*A much easier / quicker qualification is to increase the value to much high number - like 1 inch (25.4 millimeters).<br><br>
 +
*Some customers use large values (like 10 inches) to avoid this qualification from occurring completely - and making end scans much easier.<br><br>
 +
 
 +
 
 +
 
 +
</td>
 +
<td width=300>
 +
 
 +
</td>
 +
</tr>
 +
</table>
 +
 
 +
===Set the Default===
 +
 
 +
 
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=500>
 +
Set the default value by clearing the VTube project, then changing the value, then saving the setup to the default file in the System Options - Project Setup menu.<br>
 +
 
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>

Latest revision as of 04:35, 1 November 2017

Vtube-laser logo.jpg End Scan Diameter Qualification Tolerance

Vtube-laser 1 73.jpg


This feature is considered obsolete and was removed as of Version 2.9 - November 1, 2017

How the Tolerance Works



The End Scan tolerance allows VTube-LASER to control which points are accepted as potential end-scan points based on how far the points are from the A-End and B-End Diameter values.

The image illustrates a tolerance of 1 inch. Any end scan points within that region will be qualified (the orange points).The red points are outside the tolerance, so they are rejected.

The tolerance is measured from the out diameter in both directions - both positive (away from the centerline) and negative (toward the centerline).

VTube-laser-EndScanDiameterQualificationToleranceIllustration.png

How to Set the Tolerance

You can set the tolerance in two places in VTube. One place is in the System Options / Measure 2 menu.

VTube-LASER-Measure2-EndScanDiameterQualificationTolerance.png

The second place to edit the value is in the VTube-LASER Measure Setup menu's "Other" tab menu.

VTube-LASER-MeasureSetup-EndScanDiameterQualificationTolerance.png

Choosing Values

  • A tight qualification is 0.039 inches (1 millimeter). It is much more challenging to measure the end scan with a tight tolerance. Keep in mind that tube deformation will make tight tolerance end scans more challenging.

  • A much easier / quicker qualification is to increase the value to much high number - like 1 inch (25.4 millimeters).

  • Some customers use large values (like 10 inches) to avoid this qualification from occurring completely - and making end scans much easier.


Set the Default

Set the default value by clearing the VTube project, then changing the value, then saving the setup to the default file in the System Options - Project Setup menu.

Other Pages