Difference between revisions of "VTube-LASER - End Scan Diameter Qualification Tolerance"
From ATTWiki
(→Other End-Scan Information) |
(→Recommended Values) |
||
Line 58: | Line 58: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=500> | <td width=500> | ||
− | * A tight qualification is 1 millimeter. | + | * A tight qualification is 1 millimeter.<br> |
− | * A much easier / quicker qualification is to open the value up much higher - like 25 millimetes. (Many customers use 25 millimeters to avoid this qualification from occuring completely - and making end scans much easier.) | + | |
− | * Keep in mind that tube deformation will make tight end scans more challenging. | + | * A much easier / quicker qualification is to open the value up much higher - like 25 millimetes. (Many customers use 25 millimeters to avoid this qualification from occuring completely - and making end scans much easier.)<br> |
+ | |||
+ | * Keep in mind that tube deformation will make tight end scans more challenging.<br> | ||
+ | |||
+ | </td> | ||
+ | <td width=300> | ||
+ | |||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | |||
+ | |||
+ | ===Set the Default=== | ||
+ | |||
+ | |||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=500> | ||
+ | Set the default value by clearing the VTube project, then changing the value, then saving the setup to the default file in the System Options - Project Setup menu.<br> | ||
+ | |||
</td> | </td> | ||
<td width=300> | <td width=300> |
Revision as of 21:14, 25 September 2013
End Scan Diameter Qualification Tolerance
|
How the Tolerance Works
The End Scan tolerance allows VTube-LASER to control which points are accepted as potential end-scan points based on how far the points are from the A-End and B-End Diameter values. The image above illustrates a tolerance of 10 millimeters. Any end scan points within that region will be qualified. See the orange points in image. The red points are outside the tolerance, so they are rejected. |
How to Set the Tolerance
You can set the tolerance in two places in VTube. One place is in the System Options / Measure 2 menu. |
The second place to edit the value is in the VTube-LASER Measure Setup menu's "Other" tab menu. |
Recommended Values
|
Set the Default
Set the default value by clearing the VTube project, then changing the value, then saving the setup to the default file in the System Options - Project Setup menu. |
Other Pages
- Back to VTube-LASER