Difference between revisions of "VTube-LASER - End Scan Diameter Qualification Tolerance"

From ATTWiki
Jump to: navigation, search
(How the Tolerance Works)
(How the Tolerance Works)
Line 14: Line 14:
  
 
=== How the Tolerance Works ===
 
=== How the Tolerance Works ===
 
  
 
<table cellpadding=10>
 
<table cellpadding=10>
Line 22: Line 21:
 
[[image:VTube-laser-EndScanDiameterQualificationToleranceIllustration.png|500px]]<br><br>
 
[[image:VTube-laser-EndScanDiameterQualificationToleranceIllustration.png|500px]]<br><br>
  
The End Scan tolerance will control which points are accepted as potential end-scan points based on how far the points are from the A-End and B-End Diameter values.</td>
+
The End Scan tolerance allows VTube-LASER to control which points are accepted as potential end-scan points based on how far the points are from the A-End and B-End Diameter values.
 +
 
 +
The image above illustrates a tolerance of 10 millimeters.  Any end scan points within that region will be qualified.  See the orange points in image.  The red points are outside the tolerance, so they are rejected.</td>
 
<td width=300>
 
<td width=300>
  
 
[[image:VTube-LASER-Measure2-EndScanDiameterQualificationTolerance.png|300px]]
 
[[image:VTube-LASER-Measure2-EndScanDiameterQualificationTolerance.png|300px]]
 +
</td>
 +
</tr>
 +
</table>
 +
 +
 +
=== How to Set the Tolerance ===
 +
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=500>
 +
You can set the tolerance in two places in VTube.  One is in the System Options / Measure 2 menu.</td>
 +
<td width=300>
 +
[[image:VTube-LASER-Measure2-EndScanDiameterQualificationTolerance.png|300px]]
 +
</td>
 +
</tr>
 +
</table>
 +
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=500>
 +
The second place to edit the value is in the Measure Setup menu's "Other" tab menu.</td>
 +
<td width=300>
 +
[[image:VTube-LASER-MeasureSetup-EndScanDiameterQualificationTolerance.png|300px]]
 
</td>
 
</td>
 
</tr>
 
</tr>

Revision as of 21:06, 25 September 2013

Vtube-laser logo.jpg End Scan Diameter Qualification Tolerance

Vtube-laser 1 73.jpg


How the Tolerance Works

VTube-laser-EndScanDiameterQualificationToleranceIllustration.png

The End Scan tolerance allows VTube-LASER to control which points are accepted as potential end-scan points based on how far the points are from the A-End and B-End Diameter values.

The image above illustrates a tolerance of 10 millimeters. Any end scan points within that region will be qualified. See the orange points in image. The red points are outside the tolerance, so they are rejected.

VTube-LASER-Measure2-EndScanDiameterQualificationTolerance.png


How to Set the Tolerance

You can set the tolerance in two places in VTube. One is in the System Options / Measure 2 menu.

VTube-LASER-Measure2-EndScanDiameterQualificationTolerance.png

The second place to edit the value is in the Measure Setup menu's "Other" tab menu.

VTube-LASER-MeasureSetup-EndScanDiameterQualificationTolerance.png

Other End-Scan Information

  • VTube-LASER - End Scan Diameter Qualification Tolerance

Other Pages