Difference between revisions of "TubeCAD Pro v8.4"

From ATTWiki
Jump to: navigation, search
(25px FIX - Tangent Circle Orientation Precision)
(25px CHANGE: Security Change Required by New Windows Security Updates - Network Socket Logic)
 
(8 intermediate revisions by one user not shown)
Line 18: Line 18:
  
 
==[[image:Check.jpg|25px]] FIX - Tangent Circle Orientation Precision==
 
==[[image:Check.jpg|25px]] FIX - Tangent Circle Orientation Precision==
<table>
+
<table width=1000>
 
<tr>
 
<tr>
<td width=400 valign=top>
+
<td width=200 valign=top>
* It was discovered that the TubeCAD logic was not placing each bends STARTING tangent circles in the correct (perfect) orientation.  This has been fixed.<br><br>
+
* It was discovered that the TubeCAD logic was not placing each bend's STARTING tangent circle in the correct (perfect) orientation.  This has been fixed.<br><br>
 
* All views with diameters are impacted by this change.</td>
 
* All views with diameters are impacted by this change.</td>
 
<td valign=top>
 
<td valign=top>
Line 31: Line 31:
  
 
==[[image:Check.jpg|25px]] CHANGE: Security Change Required by New Windows Security Updates - Network Socket Logic ==
 
==[[image:Check.jpg|25px]] CHANGE: Security Change Required by New Windows Security Updates - Network Socket Logic ==
<table cellpadding=10>
+
<table cellpadding=10 width=1000>
 
<tr valign=top>
 
<tr valign=top>
<td width=400>
+
<td width=200>
 
We made an important change to the Network License Manager networking portion of the code for Windows compliance.<br><br>
 
We made an important change to the Network License Manager networking portion of the code for Windows compliance.<br><br>
 
TubeCAD used to open an IP socket using 0.0.0.0, then assign a working IP address based on the configuration.<br><br>
 
TubeCAD used to open an IP socket using 0.0.0.0, then assign a working IP address based on the configuration.<br><br>
 
As of the end of 2015, some Windows started throwing a critical error to TubeCAD when TubeCAD attempted to open the IP connection like this.  So now TubeCAD opens sockets with at least a local address of 127.0.0.1 - which is allowed by Windows.<br><br>
 
As of the end of 2015, some Windows started throwing a critical error to TubeCAD when TubeCAD attempted to open the IP connection like this.  So now TubeCAD opens sockets with at least a local address of 127.0.0.1 - which is allowed by Windows.<br><br>
 
</td>
 
</td>
<td width=300>
+
<td width=800>
 
[[image:blueethernetcable_rj45connector.png|400px]]
 
[[image:blueethernetcable_rj45connector.png|400px]]
 
</td>
 
</td>
Line 44: Line 44:
  
 
</table>
 
</table>
 
===[[image:Check.jpg|25px]] Other===
 
<table>
 
<tr>
 
<td width=300 valign=top>
 
* Because of automatic handling of the ARCSTEP variables, TubeCAD now performs Auto Arrange faster.</td>
 
<td valign=top>
 
</td>
 
</tr>
 
</table>
 
 
<br>
 
  
 
==Other Pages==
 
==Other Pages==

Latest revision as of 17:28, 15 January 2016

Tcadpro logo.jpg

Version 8-4 - January 14, 2016

Back to TubeCAD Pro

Tcadpro demo generated.jpg





Check.jpg FIX - Tangent Circle Orientation Precision

  • It was discovered that the TubeCAD logic was not placing each bend's STARTING tangent circle in the correct (perfect) orientation. This has been fixed.

  • All views with diameters are impacted by this change.

Tubecad pro 8.4 tangentcirclefix.png



Check.jpg CHANGE: Security Change Required by New Windows Security Updates - Network Socket Logic

We made an important change to the Network License Manager networking portion of the code for Windows compliance.

TubeCAD used to open an IP socket using 0.0.0.0, then assign a working IP address based on the configuration.

As of the end of 2015, some Windows started throwing a critical error to TubeCAD when TubeCAD attempted to open the IP connection like this. So now TubeCAD opens sockets with at least a local address of 127.0.0.1 - which is allowed by Windows.

Blueethernetcable rj45connector.png

Other Pages