Difference between revisions of "TubeCAD Pro v8-20130304"

From ATTWiki
Jump to: navigation, search
(25px ENHANCED: Changes for Multi-User Login and UAC Restrictions)
(25px NEW - Excel Import and Export)
 
(29 intermediate revisions by one user not shown)
Line 23: Line 23:
 
<td>
 
<td>
 
[[image:tcadpro_xlsio.jpg|300px]]<br>
 
[[image:tcadpro_xlsio.jpg|300px]]<br>
 +
[[image:tcadpro_excelrunning.jpg|300px]]<br>
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 29: Line 30:
 
<br>
 
<br>
  
 
+
===[[image:Check.jpg|25px]] NEW: Command "PointLabelSpacing" controls point LABEL offset===
===[[image:Check.jpg|25px]] ENHANCED: Changes for Multi-User Login and UAC Restrictions===
+
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
<td width=400>
 
TubeCAD was changed to install once in administrative mode, and then run with any new user login in Windows using the Microsoft data storage methods.<br><br>
 
* See [[How TubeCAD Handles Data Storage for Multiple User Logins]] for details.</td>
 
 
<td width=300>
 
<td width=300>
 +
TubeCAD can moves the point labels from on top of the points to outside the diameter automatically.<br><br>
 +
The direction is always along a vector formed by the bisection of the two adjacent centerlines - toward the outside of the bend.<br><br>
 +
[[image:tcadpro_pointlabel_vector.jpg|300px]]<br><br>
 +
The automatic distance is always tied to the diameter entered in General Specs.<br><br>
 +
Because of this new capability, users asked us to allow them to control how far the labels move away from the actual point object.<br><br>
 +
This new command allows you to type a factor (multiplier) that will change the distance by multiplying the factor against the automatic distance generated.<br><br>
 +
A value of 1.0 makes no change in the value.  But a value of 0.5 moves the label halfway closer to the point it is labelling.<br><br>
 +
This value affects all labels on all objects - not just the primary views.</td>
 +
<td width=300>
 +
[[image:tcadpro_pointlabelspacing_factor1.jpg|300px]]<br>Factor of "1"<br><br>
 +
[[image:tcadpro_pointlabelspacing_factor.5.jpg|300px]]
 +
<br>Factor of "0.2"
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 42: Line 51:
  
  
===[[image:Check.jpg|25px]] NEW: Command "PointLabelSpacing" controls point offset===
+
===[[image:Check.jpg|25px]] ENHANCED: Default Parts Folder Changed===
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=400>
 
<td width=400>
TubeCAD can now move the point labels from on top of the points to outside the diameter automatically.  The direction is always along a vector formed by the bisection of the two adjacent centerlines - toward the outside of the bend.<br><br>
+
TubeCAD's default part folder was changed to depend on the user logged in in Windows (See the next enhancement for details how we now handle paths).<br><br>
Because of this new capability, users asked us to allow them to control how far the labels move away from the actual point object.<br><br>
+
The path will be the "tcadpro" folder inside the "My Documents" folder.  All data types are stored in this folder from this version on.<br><br>
The automatic distance is always tied to the diameter entered in General Specs.  The new command allows you to type a factor (multiplier) that will change the distance by multiplying the factor against the automatic distance generated.<br><br>
+
(Note: This folder will be unique for each user login.)
For example: A value of 1.0 makes no change in the value.  But a value of 0.5 moves the label halfway to the point object.</td>
+
</td>
 
<td width=300>
 
<td width=300>
 +
[[image:tcadpro_mydocuments.jpg|300px]]
 
</td>
 
</td>
 +
</tr>
 +
</table>
 +
 +
===[[image:Check.jpg|25px]] ENHANCED: Changes for Multi-User Login and UAC Restrictions===
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=400>
 +
TubeCAD was changed to install once in administrative mode, and then run with any new user login in Windows using the Microsoft data storage methods.<br><br>
 +
* For IT departments: See [[How TubeCAD Handles Data Storage for Multiple User Logins]] for details.</td>
 
<td width=300>
 
<td width=300>
Factor of "1":<br>
 
[[image:tcadpro_pointlabelspacing_factor1.jpg]]<br><br>
 
Factor of "0.5":<br>
 
[[image:tcadpro_pointlabelspacing_factor.5.jpg]]
 
 
</td>
 
</td>
 
</tr>
 
</tr>
 
</table>
 
</table>
 +
 +
  
 
==Other Pages==
 
==Other Pages==
  
 
*Back to the [[TubeCAD Pro]] page
 
*Back to the [[TubeCAD Pro]] page

Latest revision as of 19:41, 6 March 2013

Tcadpro logo.jpg

Version 8-20130304

Back to TubeCAD Pro

Tcadpro demo generated.jpg



Contents

Check.jpg NEW - Excel Import and Export

TubeCAD has a new XLS command that allows you to import or export XLS files that contain XYZ centerline data.

Tcadpro xlsio window.jpg

Type "XLS" in the command line to show the new Excel window.

Tcadpro xlsio.jpg
Tcadpro excelrunning.jpg


Check.jpg NEW: Command "PointLabelSpacing" controls point LABEL offset

TubeCAD can moves the point labels from on top of the points to outside the diameter automatically.

The direction is always along a vector formed by the bisection of the two adjacent centerlines - toward the outside of the bend.

Tcadpro pointlabel vector.jpg

The automatic distance is always tied to the diameter entered in General Specs.

Because of this new capability, users asked us to allow them to control how far the labels move away from the actual point object.

This new command allows you to type a factor (multiplier) that will change the distance by multiplying the factor against the automatic distance generated.

A value of 1.0 makes no change in the value. But a value of 0.5 moves the label halfway closer to the point it is labelling.

This value affects all labels on all objects - not just the primary views.

Tcadpro pointlabelspacing factor1.jpg
Factor of "1"

Tcadpro pointlabelspacing factor.5.jpg
Factor of "0.2"


Check.jpg ENHANCED: Default Parts Folder Changed

TubeCAD's default part folder was changed to depend on the user logged in in Windows (See the next enhancement for details how we now handle paths).

The path will be the "tcadpro" folder inside the "My Documents" folder. All data types are stored in this folder from this version on.

(Note: This folder will be unique for each user login.)

Tcadpro mydocuments.jpg

Check.jpg ENHANCED: Changes for Multi-User Login and UAC Restrictions

TubeCAD was changed to install once in administrative mode, and then run with any new user login in Windows using the Microsoft data storage methods.


Other Pages