Scanning on a NEWPORT type table

From ATTWiki
Revision as of 16:39, 13 April 2016 by Mcone (Talk | contribs)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

Vtube-laser logo 1.96.png

Vtl screen hd scanner without logo.png



NEWPORT Tables

Scanning on NEWPORT tables is possible with the FARO scanner system, but care must be taken because of the high reflectivity of the surfaces in the drilled and tapped holes.

Vtube-laser v2.5 reverse tubeends.png


Reversed Point Labels

When you reverse the XYZ rows, VTube will also reverse the point labels.

With the point labels reversed, it is a good idea to look at the END LABELS rather than the POINT LABELS to determine which end to measure first.

See the effect in the image on the right. The END A label is at point 9 in this part after a reverse of the XYZ data.

Newport table.png



Reset the Reversed Point Labels

You can reset the point labels from being reversed with the XYZ reverse feature.

Right click on the XYZ grid and the click on Reset Point Labels.

Vtube v2.5 reset point labels.png Vtube v2.5 effect of reset point labels.png

Vtube-laser v2.5 tubeimage with pointlabels.png