Difference between revisions of "Revision: Benderlink for Chiyoda/Keins 6.8"

From ATTWiki
Jump to: navigation, search
(25px NEW - Every Bender Can Have Its Own Network Storage Path)
(25px UPDATE - VTube-STEP 1.93)
 
(6 intermediate revisions by one user not shown)
Line 18: Line 18:
 
==[[image:Check.jpg|25px]] NEW - Every Bender Can Have Its Own Network Storage Path ==
 
==[[image:Check.jpg|25px]] NEW - Every Bender Can Have Its Own Network Storage Path ==
  
<table cellpading=10>
+
<table cellpadding=20>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=400>
 
<td width=400>
Line 34: Line 34:
 
</table>
 
</table>
  
==[[image:Check.jpg|25px]] ENHANCED - New CONVERSION Menu Option: Stop for Zero Diameter ==
+
==[[image:Check.jpg|25px]] UPDATE - VTube-STEP 1.93 ==
  
<table>
+
<table cellpadding=20>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=400>
 
<td width=400>
  
Benderlink can now stop the process and ask for input if a zero diameter is encountered.<br><br>
+
The embedded VTube-STEP is updated to version 1.93.<br><br>
  
If this feature is deactivated, then Benderlink will ignore zero value radii values.  In this case, Benderlink will automatically change a zero value diameter to non-zero using this formula:
+
See [[VTube-STEP v1.93]] for details.
<br><br>
+
<b>(Rad Level 1) / 1.5</b><br><br>
+
If the Rad Level 1 value is zero, then Benderlink will use this formula:<br><br>
+
<b>(Rad Level 2) / 1.5</b><br><br>
+
 
+
* If both radius level values are zero, then Benderlink will set the diameter to 1 unit.<br><br>A non-zero diameter is important for communicating with ROMER [[DOCS]] software because DOCS will report a corrupted file if it senses a zero diameter.  (Some measuring center software packages, like [[VTube-LASER]] will continue with a zero diameter.)<br><br>
+
* If the radius stop is enabled, and Benderlink stops for input while the measuring center is performing a recall, then the recall process will time out if the new diameter is not entered within the time out period.
+
  
 
</td>
 
</td>
  
 
<td>
 
<td>
[[image:benderlink_chiyodakeins_stopforzerodiameter.png|400px]]
+
[[image:vtube-step-1.93_screenshot.png|400px]]
 
</td>
 
</td>
 
</tr>
 
</tr>

Latest revision as of 19:59, 12 August 2014

Blink keinschiyoda orangefire.jpg

Revision 6.8

Back to Benderlink for Chiyoda
Back to Benderlink for KEINS

Blink keinschiyoda screens 6.1.jpg



Check.jpg NEW - Every Bender Can Have Its Own Network Storage Path

Older versions of Benderlink stored bender data from all benders in a single path.

However, it is normal to keep bender setups separate for each bender since every Chiyoda bender will have a unique setup.

Examples are two Chiyoda benders with different machine lengths, or two benders that differ in bend direction (left-hand or right-hand).

This new Benderlink feature now assumes that every bender should have a unique storage path on the drive or network.

See the Bender Type Setup page to setup and control this new path per bender.

Benderlink chiyodakeins uniquedatapath.png

Check.jpg UPDATE - VTube-STEP 1.93

The embedded VTube-STEP is updated to version 1.93.

See VTube-STEP v1.93 for details.

Vtube-step-1.93 screenshot.png



OTHER PAGES