Difference between revisions of "Revision: Benderlink for Chiyoda/Keins 6.8"

From ATTWiki
Jump to: navigation, search
(25px NEW - Every Bender Can Have Its Own Network Storage Path)
(25px NEW - Every Bender Can Have Its Own Network Storage Path)
Line 21: Line 21:
 
<tr valign=top>
 
<tr valign=top>
 
<td width=400>
 
<td width=400>
Older versions of Benderlink stored bender data from all benders in a single path.<br><br>
+
Older versions of Benderlink stored bender data from all benders in a single path. However, it is normal to keep bender setups separate for each bender since every Chiyoda bender will have a unique setup.  A good example is two Chiyoda benders with different machine lengths, or two benders that differ in bend direction (left-hand or right-hand).<br><br>
It is normal to keep bender setups separate for each bender since every Chiyoda bender will have a unique setup.  A good example is two Chiyoda benders with different machine lengths, or two benders that differ in bend direction (left-hand or right-hand).<br><br>
+
 
This feature then assumes that every bender should have a unique storage path on the drive or network.<br><br>
 
This feature then assumes that every bender should have a unique storage path on the drive or network.<br><br>
 
<br><br>
 
<br><br>

Revision as of 19:35, 12 August 2014

Blink keinschiyoda orangefire.jpg

Revision 6.8

Back to Benderlink for Chiyoda
Back to Benderlink for KEINS

Blink keinschiyoda screens 6.1.jpg



Check.jpg NEW - Every Bender Can Have Its Own Network Storage Path

Older versions of Benderlink stored bender data from all benders in a single path. However, it is normal to keep bender setups separate for each bender since every Chiyoda bender will have a unique setup. A good example is two Chiyoda benders with different machine lengths, or two benders that differ in bend direction (left-hand or right-hand).

This feature then assumes that every bender should have a unique storage path on the drive or network.



Benderlink chiyodakeins uniquedatapath.png

Check.jpg ENHANCED - New CONVERSION Menu Option: Stop for Zero Diameter

Benderlink can now stop the process and ask for input if a zero diameter is encountered.

If this feature is deactivated, then Benderlink will ignore zero value radii values. In this case, Benderlink will automatically change a zero value diameter to non-zero using this formula:

(Rad Level 1) / 1.5

If the Rad Level 1 value is zero, then Benderlink will use this formula:

(Rad Level 2) / 1.5

  • If both radius level values are zero, then Benderlink will set the diameter to 1 unit.

    A non-zero diameter is important for communicating with ROMER DOCS software because DOCS will report a corrupted file if it senses a zero diameter. (Some measuring center software packages, like VTube-LASER will continue with a zero diameter.)

  • If the radius stop is enabled, and Benderlink stops for input while the measuring center is performing a recall, then the recall process will time out if the new diameter is not entered within the time out period.

Benderlink chiyodakeins stopforzerodiameter.png