Difference between revisions of "FIF Translator Version 4 - September, 2007"

From ATTWiki
Jump to: navigation, search
(NEW Conversion Features)
(Automatic Conversion of Units)
 
(6 intermediate revisions by one user not shown)
Line 1: Line 1:
[[image:Fiftrans4_fromfif.jpg|300px|right]]
+
[[image:FIF_Translator_Logo_360x70.jpg]]
 +
[[image:Fiftrans4_splash.jpg|right|300px]]
 +
 
 +
 
 
__TOC__
 
__TOC__
  
Line 6: Line 9:
  
 
=Summary of Enhancement Information=
 
=Summary of Enhancement Information=
 +
  
 
*This version retains both the XYZ and YBC data intact.  There is no forced conversion in one direction or another between the two data types.
 
*This version retains both the XYZ and YBC data intact.  There is no forced conversion in one direction or another between the two data types.
Line 16: Line 20:
  
 
=NEW Conversion Features=
 
=NEW Conversion Features=
 +
 +
 +
[[image:Fiftrans4_fromfif.jpg|300px]]
 +
  
 
<table cellpadding="15" width = 550>
 
<table cellpadding="15" width = 550>
Line 22: Line 30:
 
<tr valign="top">
 
<tr valign="top">
 
<td bgcolor="#abbad1" width=150>
 
<td bgcolor="#abbad1" width=150>
<font size=4><b>NEW for Eaton Leonard XYZ Data</b></font>
+
<font size=4><b>XYZ Data</b></font>
 
----<br>
 
----<br>
 
</td>
 
</td>
Line 41: Line 49:
 
<tr valign="top">
 
<tr valign="top">
 
<td bgcolor="#abbad1" width=150>
 
<td bgcolor="#abbad1" width=150>
<font size=4><b>NEW for Eaton Leonard YBC Data</b></font>
+
<font size=4><b>YBC (Bender) Data</b></font>
 
----<br>
 
----<br>
 
</td>
 
</td>
Line 56: Line 64:
 
<tr valign="top">
 
<tr valign="top">
 
<td bgcolor="#abbad1" width=150>
 
<td bgcolor="#abbad1" width=150>
<font size=4><b>NEW for Eaton Leonard SPEED Data</b></font>
+
<font size=4><b>SPEED Data</b></font>
 
----<br>
 
----<br>
 
</td>
 
</td>
Line 69: Line 77:
 
<tr valign="top">
 
<tr valign="top">
 
<td bgcolor="#abbad1" width=150>
 
<td bgcolor="#abbad1" width=150>
<font size=4><b>NEW for YBC FUNCTION Data</b></font>
+
<font size=4><b>FUNCTION Data</b></font>
 
----<br>
 
----<br>
 
</td>
 
</td>
Line 81: Line 89:
 
<tr valign="top">
 
<tr valign="top">
 
<td bgcolor="#abbad1" width=150>
 
<td bgcolor="#abbad1" width=150>
<font size=4><b>NEW for YBC SPECIAL FUNCTION Data</b></font>
+
<font size=4><b>SPECIAL FUNCTION Data</b></font>
 
----<br>
 
----<br>
 
</td>
 
</td>
Line 92: Line 100:
 
<tr valign="top">
 
<tr valign="top">
 
<td bgcolor="#abbad1" width=150>
 
<td bgcolor="#abbad1" width=150>
<font size=4><b>NEW Eaton Leonard SETUP Data to SUPRAVISION PROCESS Data</b></font>
+
<font size=4><b>EATON LEONARD SETUP Data</b></font>
 
----<br>
 
----<br>
 
</td>
 
</td>
Line 106: Line 114:
 
<tr valign="top">
 
<tr valign="top">
 
<td bgcolor="#abbad1" width=150>
 
<td bgcolor="#abbad1" width=150>
<font size=4><b>NEW Eaton Leonard TOOL Data to SUPRAVISION MACHINE DATA</b></font>
+
<font size=4><b>EATON LEONARD TOOL Data</b></font>
 
----<br>
 
----<br>
 
</td>
 
</td>
Line 124: Line 132:
 
<tr valign="top">
 
<tr valign="top">
 
<td bgcolor="#abbad1" width=150>
 
<td bgcolor="#abbad1" width=150>
<font size=4><b>NEW Eaton Leonard Setup Data to SUPRAVISION MACHINE DATA</b></font>
+
<font size=4><b>EATON LEONARD SETUP Data</b></font>
 
----<br>
 
----<br>
 
</td>
 
</td>
Line 143: Line 151:
 
<tr valign="top">
 
<tr valign="top">
 
<td bgcolor="#abbad1" width=150>
 
<td bgcolor="#abbad1" width=150>
<font size=4><b>NEW Eaton Leonard Extended Setup Data to SUPRAVISION MACHINE DATA</b></font>
+
<font size=4><b>EATON LEONARD EXTENDED SETUP Data</b></font>
 
----<br>
 
----<br>
 
</td>
 
</td>
Line 159: Line 167:
 
''Note: This does not apply to the EXTENDED Setup data, as Supravision does not attempt to convert these values between units.
 
''Note: This does not apply to the EXTENDED Setup data, as Supravision does not attempt to convert these values between units.
 
''
 
''
 +
 +
 +
== Other Pages ==
 +
* Back to [[Conversion]]
 +
* Back to [[FIF Translator]]
 +
* See [[FIF Translator Upgrade Policy]] for information on how to upgrade

Latest revision as of 14:24, 26 August 2009

FIF Translator Logo 360x70.jpg

Fiftrans4 splash.jpg


Contents



Summary of Enhancement Information

  • This version retains both the XYZ and YBC data intact. There is no forced conversion in one direction or another between the two data types.
  • Now ALL data found in an FIF file is converted to the Supravision format.
  • Distance data can be automatically converted to the other unit (Millimeters to Inches, or Inches to Millimeters).
  • Improved error handling.

NEW Conversion Features

Fiftrans4 fromfif.jpg


XYZ Data



In addition to the XYZ points and bend RADII...


  • NEW - Properly skip REFERENCE points in the XYZ data. (Reference points are not intersection or end points. They are not used to define the shape of the tube.)


  • NEW - Retain XYZ data as it exists in the FIF file. No longer attempt a recalc from YBC to XYZ. This allows measuring centers to be sure to retain original XYZ MASTER data during conversion.


YBC (Bender) Data



In addition to the YBC data...

  • NEW - Retain YBC data as it exists in the FIF file. No longer attempt a recalc from XYZ to YBC. This allows measuring centers to retain original YBC bender setup data during conversion.

SPEED Data



  • NEW - Conversion of YBC axes speeds: 1 - 8

FUNCTION Data



  • NEW - Conversion of all YBC FUNCTION Bits (12345678)

SPECIAL FUNCTION Data



  • NEW - Conversion of all YBC FUNCTION STOP and LAST Bits

EATON LEONARD SETUP Data



NEW PROCESS VALUES CONVERTED:

  • NEW - Default Radius (from first radius level)
  • NEW - End A Diameter
  • NEW - End B Diameter

EATON LEONARD TOOL Data



Handles Up to 9 Radius Levels - EACH LEVEL can contain:

  • NEW - Radius
  • NEW - Fixed Springback
  • NEW - Proportional Springback
  • NEW - Clamp Length
  • NEW - Clearance Feed
  • NEW - Clearance Angle

EATON LEONARD SETUP Data



  • NEW - Ymin
  • NEW - Interference Zone 1
  • NEW - Interference Zone 2
  • NEW - Load Position
  • NEW - Load Offset
  • NEW - Y Position Tolerance
  • NEW - Pressure Die Open Code
  • NEW - Boost Delay

EATON LEONARD EXTENDED SETUP Data



  • NEW - Up to 99 EXTENDED setup values are automatically converted

Automatic Conversion of Units

Fiftrans4 convertunit.jpg

NEW - All distance values can be automatically converted to the opposite unit during conversion.

Note: This does not apply to the EXTENDED Setup data, as Supravision does not attempt to convert these values between units.


Other Pages