Difference between revisions of "FIF Translator Version 4 - September, 2007"
From ATTWiki
(→NEW Conversion Features) |
(→Automatic Conversion of Units) |
||
(6 intermediate revisions by one user not shown) | |||
Line 1: | Line 1: | ||
− | [[image: | + | [[image:FIF_Translator_Logo_360x70.jpg]] |
+ | [[image:Fiftrans4_splash.jpg|right|300px]] | ||
+ | |||
+ | |||
__TOC__ | __TOC__ | ||
Line 6: | Line 9: | ||
=Summary of Enhancement Information= | =Summary of Enhancement Information= | ||
+ | |||
*This version retains both the XYZ and YBC data intact. There is no forced conversion in one direction or another between the two data types. | *This version retains both the XYZ and YBC data intact. There is no forced conversion in one direction or another between the two data types. | ||
Line 16: | Line 20: | ||
=NEW Conversion Features= | =NEW Conversion Features= | ||
+ | |||
+ | |||
+ | [[image:Fiftrans4_fromfif.jpg|300px]] | ||
+ | |||
<table cellpadding="15" width = 550> | <table cellpadding="15" width = 550> | ||
Line 22: | Line 30: | ||
<tr valign="top"> | <tr valign="top"> | ||
<td bgcolor="#abbad1" width=150> | <td bgcolor="#abbad1" width=150> | ||
− | <font size=4><b> | + | <font size=4><b>XYZ Data</b></font> |
----<br> | ----<br> | ||
</td> | </td> | ||
Line 41: | Line 49: | ||
<tr valign="top"> | <tr valign="top"> | ||
<td bgcolor="#abbad1" width=150> | <td bgcolor="#abbad1" width=150> | ||
− | <font size=4><b> | + | <font size=4><b>YBC (Bender) Data</b></font> |
----<br> | ----<br> | ||
</td> | </td> | ||
Line 56: | Line 64: | ||
<tr valign="top"> | <tr valign="top"> | ||
<td bgcolor="#abbad1" width=150> | <td bgcolor="#abbad1" width=150> | ||
− | <font size=4><b> | + | <font size=4><b>SPEED Data</b></font> |
----<br> | ----<br> | ||
</td> | </td> | ||
Line 69: | Line 77: | ||
<tr valign="top"> | <tr valign="top"> | ||
<td bgcolor="#abbad1" width=150> | <td bgcolor="#abbad1" width=150> | ||
− | <font size=4><b> | + | <font size=4><b>FUNCTION Data</b></font> |
----<br> | ----<br> | ||
</td> | </td> | ||
Line 81: | Line 89: | ||
<tr valign="top"> | <tr valign="top"> | ||
<td bgcolor="#abbad1" width=150> | <td bgcolor="#abbad1" width=150> | ||
− | <font size=4><b> | + | <font size=4><b>SPECIAL FUNCTION Data</b></font> |
----<br> | ----<br> | ||
</td> | </td> | ||
Line 92: | Line 100: | ||
<tr valign="top"> | <tr valign="top"> | ||
<td bgcolor="#abbad1" width=150> | <td bgcolor="#abbad1" width=150> | ||
− | <font size=4><b> | + | <font size=4><b>EATON LEONARD SETUP Data</b></font> |
----<br> | ----<br> | ||
</td> | </td> | ||
Line 106: | Line 114: | ||
<tr valign="top"> | <tr valign="top"> | ||
<td bgcolor="#abbad1" width=150> | <td bgcolor="#abbad1" width=150> | ||
− | <font size=4><b> | + | <font size=4><b>EATON LEONARD TOOL Data</b></font> |
----<br> | ----<br> | ||
</td> | </td> | ||
Line 124: | Line 132: | ||
<tr valign="top"> | <tr valign="top"> | ||
<td bgcolor="#abbad1" width=150> | <td bgcolor="#abbad1" width=150> | ||
− | <font size=4><b> | + | <font size=4><b>EATON LEONARD SETUP Data</b></font> |
----<br> | ----<br> | ||
</td> | </td> | ||
Line 143: | Line 151: | ||
<tr valign="top"> | <tr valign="top"> | ||
<td bgcolor="#abbad1" width=150> | <td bgcolor="#abbad1" width=150> | ||
− | <font size=4><b> | + | <font size=4><b>EATON LEONARD EXTENDED SETUP Data</b></font> |
----<br> | ----<br> | ||
</td> | </td> | ||
Line 159: | Line 167: | ||
''Note: This does not apply to the EXTENDED Setup data, as Supravision does not attempt to convert these values between units. | ''Note: This does not apply to the EXTENDED Setup data, as Supravision does not attempt to convert these values between units. | ||
'' | '' | ||
+ | |||
+ | |||
+ | == Other Pages == | ||
+ | * Back to [[Conversion]] | ||
+ | * Back to [[FIF Translator]] | ||
+ | * See [[FIF Translator Upgrade Policy]] for information on how to upgrade |
Latest revision as of 14:24, 26 August 2009
Contents |
Summary of Enhancement Information
- This version retains both the XYZ and YBC data intact. There is no forced conversion in one direction or another between the two data types.
- Now ALL data found in an FIF file is converted to the Supravision format.
- Distance data can be automatically converted to the other unit (Millimeters to Inches, or Inches to Millimeters).
- Improved error handling.
NEW Conversion Features
XYZ Data |
In addition to the XYZ points and bend RADII...
|
YBC (Bender) Data |
In addition to the YBC data...
|
SPEED Data |
|
FUNCTION Data |
|
SPECIAL FUNCTION Data |
|
EATON LEONARD SETUP Data |
NEW PROCESS VALUES CONVERTED:
|
EATON LEONARD TOOL Data |
Handles Up to 9 Radius Levels - EACH LEVEL can contain:
|
EATON LEONARD SETUP Data |
|
EATON LEONARD EXTENDED SETUP Data |
|
Automatic Conversion of Units
NEW - All distance values can be automatically converted to the opposite unit during conversion.
Note: This does not apply to the EXTENDED Setup data, as Supravision does not attempt to convert these values between units.
Other Pages
- Back to Conversion
- Back to FIF Translator
- See FIF Translator Upgrade Policy for information on how to upgrade