Difference between revisions of "FIF Translator Version 4 - September, 2007"

From ATTWiki
Jump to: navigation, search
(Automatic Conversion of Units)
(Automatic Conversion of Units)
 
(23 intermediate revisions by one user not shown)
Line 1: Line 1:
 +
[[image:FIF_Translator_Logo_360x70.jpg]]
 +
[[image:Fiftrans4_splash.jpg|right|300px]]
 +
 +
 
__TOC__
 
__TOC__
  
  
=Enhancements Information=
+
 
 +
 
 +
=Summary of Enhancement Information=
 +
 
 +
 
 +
*This version retains both the XYZ and YBC data intact.  There is no forced conversion in one direction or another between the two data types.
  
 
*Now ALL data found in an FIF file is converted to the Supravision format.
 
*Now ALL data found in an FIF file is converted to the Supravision format.
 +
 
*Distance data can be automatically converted to the other unit (Millimeters to Inches, or Inches to Millimeters).
 
*Distance data can be automatically converted to the other unit (Millimeters to Inches, or Inches to Millimeters).
 +
 
*Improved error handling.
 
*Improved error handling.
*This version retains both the XYZ and YBC data intact.  There is no forced conversion in one direction or another between the two data types.
+
 
 +
=NEW Conversion Features=
  
  
 +
[[image:Fiftrans4_fromfif.jpg|300px]]
  
=NEW Data Included In Conversion=
 
  
 
<table cellpadding="15" width = 550>
 
<table cellpadding="15" width = 550>
Line 18: Line 30:
 
<tr valign="top">
 
<tr valign="top">
 
<td bgcolor="#abbad1" width=150>
 
<td bgcolor="#abbad1" width=150>
<font size=4><b>XYZ DATA</b></font>
+
<font size=4><b>XYZ Data</b></font>
 
----<br>
 
----<br>
 
</td>
 
</td>
  
 
<td bgcolor="#e3e4f5">
 
<td bgcolor="#e3e4f5">
*NEW - Properly skip REFERENCE points in the XYZ data.  (Reference points are not intersection or end points. They are not used to define the shape of the tube.)
+
In addition to the XYZ points and bend RADII...<br>
  
 +
 +
*NEW - Properly skip REFERENCE points in the XYZ data.  (Reference points are not intersection or end points.  They are not used to define the shape of the tube.)
 +
<br>
 
*NEW - Retain XYZ data as it exists in the FIF file.  No longer attempt a recalc from YBC to XYZ.  This allows measuring centers to be sure to retain original XYZ MASTER data during conversion.
 
*NEW - Retain XYZ data as it exists in the FIF file.  No longer attempt a recalc from YBC to XYZ.  This allows measuring centers to be sure to retain original XYZ MASTER data during conversion.
 +
 +
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 32: Line 49:
 
<tr valign="top">
 
<tr valign="top">
 
<td bgcolor="#abbad1" width=150>
 
<td bgcolor="#abbad1" width=150>
<font size=4><b>YBC DATA</b></font>
+
<font size=4><b>YBC (Bender) Data</b></font>
 
----<br>
 
----<br>
 
</td>
 
</td>
  
 
<td bgcolor="#e3e4f5">
 
<td bgcolor="#e3e4f5">
 +
In addition to the YBC data...
 +
 
*NEW - Retain YBC data as it exists in the FIF file.  No longer attempt a recalc from XYZ to YBC.  This allows measuring centers to retain original YBC bender setup data during conversion.
 
*NEW - Retain YBC data as it exists in the FIF file.  No longer attempt a recalc from XYZ to YBC.  This allows measuring centers to retain original YBC bender setup data during conversion.
 
</td>
 
</td>
Line 45: Line 64:
 
<tr valign="top">
 
<tr valign="top">
 
<td bgcolor="#abbad1" width=150>
 
<td bgcolor="#abbad1" width=150>
<font size=4><b>VELOCITY DATA</b></font>
+
<font size=4><b>SPEED Data</b></font>
 
----<br>
 
----<br>
 
</td>
 
</td>
Line 58: Line 77:
 
<tr valign="top">
 
<tr valign="top">
 
<td bgcolor="#abbad1" width=150>
 
<td bgcolor="#abbad1" width=150>
<font size=4><b>FUNCTION DATA</b></font>
+
<font size=4><b>FUNCTION Data</b></font>
 
----<br>
 
----<br>
 
</td>
 
</td>
Line 70: Line 89:
 
<tr valign="top">
 
<tr valign="top">
 
<td bgcolor="#abbad1" width=150>
 
<td bgcolor="#abbad1" width=150>
<font size=4><b>SPECIAL FUNCTION DATA</b></font>
+
<font size=4><b>SPECIAL FUNCTION Data</b></font>
 
----<br>
 
----<br>
 
</td>
 
</td>
Line 81: Line 100:
 
<tr valign="top">
 
<tr valign="top">
 
<td bgcolor="#abbad1" width=150>
 
<td bgcolor="#abbad1" width=150>
<font size=4><b>PROCESS DATA</b></font>
+
<font size=4><b>EATON LEONARD SETUP Data</b></font>
 
----<br>
 
----<br>
 
</td>
 
</td>
Line 95: Line 114:
 
<tr valign="top">
 
<tr valign="top">
 
<td bgcolor="#abbad1" width=150>
 
<td bgcolor="#abbad1" width=150>
<font size=4><b>TOOL DATA</b></font>
+
<font size=4><b>EATON LEONARD TOOL Data</b></font>
 
----<br>
 
----<br>
 
</td>
 
</td>
  
 
<td bgcolor="#e3e4f5">
 
<td bgcolor="#e3e4f5">
Handles Up to 9 Radius Levels for:
+
Handles Up to 9 Radius Levels - EACH LEVEL can contain:
 
*NEW - Radius
 
*NEW - Radius
 
*NEW - Fixed Springback
 
*NEW - Fixed Springback
Line 113: Line 132:
 
<tr valign="top">
 
<tr valign="top">
 
<td bgcolor="#abbad1" width=150>
 
<td bgcolor="#abbad1" width=150>
<font size=4><b>MACHINE DATA from EL Setup Data</b></font>
+
<font size=4><b>EATON LEONARD SETUP Data</b></font>
 
----<br>
 
----<br>
 
</td>
 
</td>
Line 132: Line 151:
 
<tr valign="top">
 
<tr valign="top">
 
<td bgcolor="#abbad1" width=150>
 
<td bgcolor="#abbad1" width=150>
<font size=4><b>NEW MACHINE DATA from EL Extended Setup Data</b></font>
+
<font size=4><b>EATON LEONARD EXTENDED SETUP Data</b></font>
 
----<br>
 
----<br>
 
</td>
 
</td>
Line 143: Line 162:
  
 
=Automatic Conversion of Units=
 
=Automatic Conversion of Units=
 +
[[image:Fiftrans4_convertunit.jpg|thumb|300px]]
 +
NEW - All distance values can be automatically converted to the opposite unit during conversion.
 +
 +
''Note: This does not apply to the EXTENDED Setup data, as Supravision does not attempt to convert these values between units.
 +
''
 +
  
NEW - All distance values can be automatically converted to the opposite unit during conversion.  (This does not apply to the EXTENDED Setup data, as Supravision does not attempt to convert these values between units.)
+
== Other Pages ==
 +
* Back to [[Conversion]]
 +
* Back to [[FIF Translator]]
 +
* See [[FIF Translator Upgrade Policy]] for information on how to upgrade

Latest revision as of 14:24, 26 August 2009

FIF Translator Logo 360x70.jpg

Fiftrans4 splash.jpg


Contents



Summary of Enhancement Information

  • This version retains both the XYZ and YBC data intact. There is no forced conversion in one direction or another between the two data types.
  • Now ALL data found in an FIF file is converted to the Supravision format.
  • Distance data can be automatically converted to the other unit (Millimeters to Inches, or Inches to Millimeters).
  • Improved error handling.

NEW Conversion Features

Fiftrans4 fromfif.jpg


XYZ Data



In addition to the XYZ points and bend RADII...


  • NEW - Properly skip REFERENCE points in the XYZ data. (Reference points are not intersection or end points. They are not used to define the shape of the tube.)


  • NEW - Retain XYZ data as it exists in the FIF file. No longer attempt a recalc from YBC to XYZ. This allows measuring centers to be sure to retain original XYZ MASTER data during conversion.


YBC (Bender) Data



In addition to the YBC data...

  • NEW - Retain YBC data as it exists in the FIF file. No longer attempt a recalc from XYZ to YBC. This allows measuring centers to retain original YBC bender setup data during conversion.

SPEED Data



  • NEW - Conversion of YBC axes speeds: 1 - 8

FUNCTION Data



  • NEW - Conversion of all YBC FUNCTION Bits (12345678)

SPECIAL FUNCTION Data



  • NEW - Conversion of all YBC FUNCTION STOP and LAST Bits

EATON LEONARD SETUP Data



NEW PROCESS VALUES CONVERTED:

  • NEW - Default Radius (from first radius level)
  • NEW - End A Diameter
  • NEW - End B Diameter

EATON LEONARD TOOL Data



Handles Up to 9 Radius Levels - EACH LEVEL can contain:

  • NEW - Radius
  • NEW - Fixed Springback
  • NEW - Proportional Springback
  • NEW - Clamp Length
  • NEW - Clearance Feed
  • NEW - Clearance Angle

EATON LEONARD SETUP Data



  • NEW - Ymin
  • NEW - Interference Zone 1
  • NEW - Interference Zone 2
  • NEW - Load Position
  • NEW - Load Offset
  • NEW - Y Position Tolerance
  • NEW - Pressure Die Open Code
  • NEW - Boost Delay

EATON LEONARD EXTENDED SETUP Data



  • NEW - Up to 99 EXTENDED setup values are automatically converted

Automatic Conversion of Units

Fiftrans4 convertunit.jpg

NEW - All distance values can be automatically converted to the opposite unit during conversion.

Note: This does not apply to the EXTENDED Setup data, as Supravision does not attempt to convert these values between units.


Other Pages