Configuring Machine Lube Settings

From ATTWiki
Revision as of 21:08, 28 January 2009 by Mcone (Talk | contribs)

Jump to: navigation, search

Cncbender logo.jpg

Contents


In the CNCProcessor.cfg File

The CNCProcessor.cfg contains the property values that allow you adjust the Machine Lube setup in CNC Bender. For more about the config file, see CNCProcessor.cfg.


Configuration Section: "Machine Lube"

The settings in this file are separated by sections with section names in square brackets. This is an example:

[Machine Lube]
Machine Lube Duration=5000
Lube Machine At Bend Count=100
Pulse Machine Lube Pump=1
Watch For Machine Lube Complete Input=0

The four values above control the machine lube features in CNC Bender.

Value 1: "Machine Lube Duration"

Value 2: "Lube Machine At Bend Count"

Value 3: "Pulse Machine Lube Pump"

Value 4: "Watch For Machine Lube Complete Input"

Other Pages