Difference between revisions of "CNC Bender v12.1.1"

From ATTWiki
Jump to: navigation, search
(25px NEW: Processor Now Checks to See if Inputs are Internal)
(25px Other Changes)
 
(23 intermediate revisions by one user not shown)
Line 1: Line 1:
 
<table>
 
<table>
 
<tr>
 
<tr>
<td width=200>
+
<td width=400>
==v12.1 - August 14, 2013==
+
===v12.1.1 - August 26, 2013===
 
*Back to [[CNC Bender Software Updates]]
 
*Back to [[CNC Bender Software Updates]]
 
+
*See [http://advancedtubular.com/customers/cncbender CNC Bender Customer Service Page] for an update.
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
Line 13: Line 13:
 
</tr>
 
</tr>
 
</table>
 
</table>
 +
 
__NOTOC__
 
__NOTOC__
  
See [http://advancedtubular.com/customers/cncbender CNC Bender Customer Service Page] for an update.
 
  
===[[image:Check.jpg|25px]] FIX: FRB Clear Part Fixed ===
+
==[[image:Check.jpg|25px]] FIX: FRB Clear Part Fixed ==
<table cellpadding=10>
+
<tr valign=top>
+
<td width=500>
+
 
CNC Bender would save parts after a FRB clear by default in the c:\cnc\config folder.  This was repaired so that it saves inside the the correct parts folder.
 
CNC Bender would save parts after a FRB clear by default in the c:\cnc\config folder.  This was repaired so that it saves inside the the correct parts folder.
</td>
 
  
<td width=300>
+
==[[image:Check.jpg|25px]] NEW: Processor Now Checks to See if Inputs are Internal==
</td>
+
CNC Processor can now check if an input is an internal input that is not connected to a physical input.  This is used for setting and reading states inside the Processor without using actual physical I/O.
</tr>
+
 
</table>
+
==[[image:Check.jpg|25px]] FIX: CNC Bender Benderlink Fix with Laservision==
 +
CNC Bender Benderlink would sometimes return an out-of-bounds error after receiving Laservision data.  This was related to setting the first straight adjustment value to zero. It has been resolved.
  
===[[image:Check.jpg|25px]] NEW: Processor Now Checks to See if Inputs are Internal===
+
==[[image:Check.jpg|25px]] ENHANCED: CNC Bender Benderlink Can Emulated Hyprex Laservision==
 +
CNC Bender Benderlink can emulate the Hyprex Laservision mode which handles 21 characters in the part name rather than 14 characaters.<br><br>
 +
[[image:cncbender_12.1_benderlink_hyprex.png|500px]]
 +
 
 +
==[[image:Check.jpg|25px]] Other Changes==
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
<td width=500>
 
CNC Processor can now check if an input is an internal input that is not connected to a physical input.  This is used for setting and reading states inside the Processor without using actual physical I/O.<br><br>
 
</td>
 
 
<td width=300>
 
<td width=300>
</td>
 
</tr>
 
</table>
 
  
===[[image:Check.jpg|25px]] Other Changes===
+
* Forward PDA Outputs are cleared when the operator enters CYCLE HOLD.  No other outputs are changed when this event occurs.
<table cellpadding=10>
+
<tr valign=top>
+
<td width=300>
+
  
 
</td>
 
</td>
Line 51: Line 43:
 
</table>
 
</table>
  
=Other Pages=
+
==Other Pages==
 
*Back to [[CNC Bender]]
 
*Back to [[CNC Bender]]
 
*Back to [[CNC Bender Software Updates]]
 
*Back to [[CNC Bender Software Updates]]

Latest revision as of 17:52, 28 August 2013

v12.1.1 - August 26, 2013

Cncv12procontrol withteachmode.jpg



Check.jpg FIX: FRB Clear Part Fixed

CNC Bender would save parts after a FRB clear by default in the c:\cnc\config folder. This was repaired so that it saves inside the the correct parts folder.

Check.jpg NEW: Processor Now Checks to See if Inputs are Internal

CNC Processor can now check if an input is an internal input that is not connected to a physical input. This is used for setting and reading states inside the Processor without using actual physical I/O.

Check.jpg FIX: CNC Bender Benderlink Fix with Laservision

CNC Bender Benderlink would sometimes return an out-of-bounds error after receiving Laservision data. This was related to setting the first straight adjustment value to zero. It has been resolved.

Check.jpg ENHANCED: CNC Bender Benderlink Can Emulated Hyprex Laservision

CNC Bender Benderlink can emulate the Hyprex Laservision mode which handles 21 characters in the part name rather than 14 characaters.

Cncbender 12.1 benderlink hyprex.png

Check.jpg Other Changes

  • Forward PDA Outputs are cleared when the operator enters CYCLE HOLD. No other outputs are changed when this event occurs.

Other Pages