This version solved an early mandrel extraction logic problem where the mandrel will extract for a split second, then stop extracting.  This is an issue on newer versions of CNC Processor that are much faster than older versions.  The quickness of the loop causes the logic problem.<br><br>
+
This version solved an early mandrel extraction logic problem where the mandrel will extract for a split second, then stop extracting.  This is an issue on newer versions of CNC Processor that are much faster than older versions.  The quickness of the loop causes the process to believe that the mandrel needs to stop retracting before it has returned completely.<br><br>
  
CNC Processor no longer checks to see if the mandrel forward output is active before it starts the extraction.  The retract output will be energized in every case during an early mandrel extraction.<br><br>
+
CNC Processor no longer checks to see if the mandrel forward output is active before it starts the extraction.  The retract output will be energized in every case during an early mandrel extraction when the bend arm is in the early mandrel extraction zone.<br><br>
 
+
This version fixes that issue that the transmission works with the new Windows version of Vector Laservision.
+
 
</td>
 
</td>
  
Line 32: Line 30:
 
</tr>
 
</tr>
 
</table>
 
</table>
 
  
 
=Other Pages=
 
=Other Pages=

Latest revision as of 19:39, 24 September 2012

v12-20120919

Cncv12procontrol withteachmode.jpg


Check.jpg REPAIR: Fixed Early Mandrel Extraction Logic

This version solved an early mandrel extraction logic problem where the mandrel will extract for a split second, then stop extracting. This is an issue on newer versions of CNC Processor that are much faster than older versions. The quickness of the loop causes the process to believe that the mandrel needs to stop retracting before it has returned completely.

CNC Processor no longer checks to see if the mandrel forward output is active before it starts the extraction. The retract output will be energized in every case during an early mandrel extraction when the bend arm is in the early mandrel extraction zone.