Cncv12procontrol withteachmode.jpg

Check.jpg Repair - Processlist Builder Proper Tracking of Option in or out of Toolbox

By default, dynamic options should be OFF or in their DEFAULT state when in a Toolbox.

However, the CNC Processlist Builder improperly tracked if an option was inside the toolbox. This sometimes caused hard-to-trace side-effects where an option seemed to be OUT of the Toolbox to Processlist Builder, but was inside the Toolbox in CNC Bender. Unintended effects could be as serious as skipping bends for example.

This version fixes this issue by allowing both CNC Bender, CNC Processlist Builder and CNC Processor to track if the operator has placed the option in the Toolbox based on which operator station the part is running in.

Check.jpg Repair - Mixed up or Garbled SVNET Data from Poor Network Connection

The Supravision data incoming to CNC Bender Benderlink could be garbled if Benderlink tried to open and access the data to early - while the file is still growing. Benderlink is now enhanced to watch for the file growth size to stop before opening and taking ownership of the incoming Supravision data.