The new Default Jog Speed value is shown here in a main.axislist file:<br><br>
 
The new Default Jog Speed value is shown here in a main.axislist file:<br><br>
 
[[image:defaultjogspeed.jpg]]
 
[[image:defaultjogspeed.jpg]]
 +
<br><br>
 +
Each axis has its own Default Jog Speed property.
 
</td>
 
</td>
 
</tr>
 
</tr>

Revision as of 16:08, 3 November 2010

Cncv12procontrol withteachmode.jpg

Contents


Check.jpg NEW Splash

CNC Bender has a new splash screen

Cncbender splash orange.jpg

Check.jpg NEW - Dedicated Timer in CNC Processor for Joystick Jog

A new timer is added to CNC Processor to regulate the response to joystick-type jog motion. This allows for steady jog motion no matter what other process the processor performing.


Check.jpg NEW - Default Jog Speed in Axislist Configuration

The default jog speeds for each axis are now set inside the main.axislist configuration file.

The speeds are reset to default:

  1. When Processor runs the Init Axis processlist
  2. When Processor senses a change between operation modes (manual, step, auto)
  3. When exiting the Custom Command Editor


Value handling:

  • If the default jog speed property and value are not present or the property name is misspelled in the main.axislist file for any axis, then the value defaults to "20" inside CNC Processor.
  • If a default jog speed is negative, it is reset to the positive value.
  • If a default jog speed exceeds the maximum speed for an axis, then it is reset to the maximum speed.

The new property name is "Default Jog Speed="

The new Default Jog Speed value is shown here in a main.axislist file:

Defaultjogspeed.jpg

Each axis has its own Default Jog Speed property.