Difference between revisions of "CNC Bender v12-20101021"

From ATTWiki
Jump to: navigation, search
(25px NEW - FEED TORQUE ZEROED DURING MANDREL RETRACT)
(25px CHANGED- KEYBOARD HANDLING)
 
(12 intermediate revisions by one user not shown)
Line 12: Line 12:
 
<br>
 
<br>
  
===[[image:Check.jpg|25px]] NEW - Added Input Timer in PreEnable  ===
+
===[[image:Check.jpg|25px]] NEW - Added Input Timer in PreEnable Processlist ===
  
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=200>
 
<td width=200>
Schneider Lexium drives require a pulse to switch from READY to RUN mode.  This feature was added to allow for pulsing Lexium drives a specific amount of time before the axes were enabled.<br><br>
+
Schneider Lexium drives require a pulse to switch from READY to RUN mode.  <br><br>
 +
 
 +
Input TIMERS are now allowed in the PreEnable processlist to pulse the Lexium drives with an output point for a specific amount of time before the axes were enabled.<br><br>
 
</td>
 
</td>
 
<td>
 
<td>
Line 26: Line 28:
 
</table>
 
</table>
  
===[[image:Check.jpg|25px]] FIXED - Early Mandrel Extra On Last Bend  ===
+
===[[image:Check.jpg|25px]] FIXED - Early Mandrel Extract On Last Bend  ===
  
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=200>
 
<td width=200>
For benders with motion controlled PDA - the early mandrel extract now works.<br><br>
+
For benders with motion-controlled [[PDA]] - the early mandrel extract now works.<br><br>
(Image from [http://www.toolsforbending.com/mandrels.asp Tools For Bending web site])
+
(Image courtesy of [http://www.toolsforbending.com/mandrels.asp Tools For Bending web site])
 
</td>
 
</td>
 
<td>
 
<td>
Line 47: Line 49:
 
<tr valign=top>
 
<tr valign=top>
 
<td width=200>
 
<td width=200>
The keyboard features were completely locked out of previous user interfaces to prevent a problem with accidental motion in the MANUAL page.  This was too drastic and restrictive for operators that wanted to use the keyboard.
+
The keyboard features were completely locked out of previous main-window user interfaces to prevent a problem with accidental motion in the MANUAL page.  This was too drastic and restrictive for operators that wanted to use the keyboard.
 
<br><br>
 
<br><br>
Now the keyboard works in every part of the user interface except for the manual buttons that can cause motion.
+
Now the keyboard works in every part of the user interface except with the manual buttons that can cause motion.  Manual buttons will not receive any keyboard input.
 
</td>
 
</td>
 
<td>
 
<td>
 
+
[[image:keyboard.jpg|150px]]
 
</td>
 
</td>
 
</tr>
 
</tr>

Latest revision as of 21:05, 22 October 2010

Cncv12procontrol withteachmode.jpg

Contents


Check.jpg NEW - Added Input Timer in PreEnable Processlist

Schneider Lexium drives require a pulse to switch from READY to RUN mode.

Input TIMERS are now allowed in the PreEnable processlist to pulse the Lexium drives with an output point for a specific amount of time before the axes were enabled.

Lexium drive motor.jpg

Check.jpg FIXED - Early Mandrel Extract On Last Bend

For benders with motion-controlled PDA - the early mandrel extract now works.

(Image courtesy of Tools For Bending web site)

Ball mandrel.jpg

Check.jpg CHANGED- KEYBOARD HANDLING

The keyboard features were completely locked out of previous main-window user interfaces to prevent a problem with accidental motion in the MANUAL page. This was too drastic and restrictive for operators that wanted to use the keyboard.

Now the keyboard works in every part of the user interface except with the manual buttons that can cause motion. Manual buttons will not receive any keyboard input.

Keyboard.jpg

Other Pages