Difference between revisions of "CNC Bender v11-20091123"

From ATTWiki
Jump to: navigation, search
(25px NEW- Better Warning for Missing Processlists)
 
(13 intermediate revisions by one user not shown)
Line 11: Line 11:
 
</td>
 
</td>
 
<td>
 
<td>
The changes in this version are additions to CNC Bender for better editing and reporting.
+
The changes in this version are changes to CNC Bender for better flexibility - including new operating systems.
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 25: Line 25:
 
__NOTOC__
 
__NOTOC__
  
 +
 +
===[[image:Check.jpg|25px]] NEW- CNC Bender Can Now Run in 32 or 64 bit Windows Vista and Windows 7===
 +
<table>
 +
<tr valign=top>
 +
<td width=300>
 +
* CNC Bender previously only ran on Windows 2000 or Windows XP.<br><br> 
 +
* Now the licensing code is new and allows for operation in Windows Vista and Windows 7 either 32 or 64 bit versions.
 +
<br><br>
 +
</td>
 +
 +
<td>
 +
 +
[[image:Win_vista_logo.jpg|right|100px]]
 +
[[image:win7logo.jpg|right|100px]]
 +
</td>
 +
</tr>
 +
 +
</table>
 +
 +
<br><br>
  
 
===[[image:Check.jpg|25px]] NEW- Editor for High Speed Constant Run Processlist===
 
===[[image:Check.jpg|25px]] NEW- Editor for High Speed Constant Run Processlist===
Line 38: Line 58:
  
 
<td>
 
<td>
[[image:highspeed_constantrun_processlist.jpg|300px]]
+
[[image:highspeed_constantrun_processlist.jpg|400px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 54: Line 74:
  
 
<td>
 
<td>
[[image:warning_missing_processlist_file.jpg]]
+
[[image:warning_missing_processlist_file.jpg|400px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 60: Line 80:
 
</table>
 
</table>
  
===[[image:Check.jpg|25px]] REPAIR - Feed Move into Interference Zones for AFTER Check for PD (Pressure Die) HOME ===
+
===[[image:Check.jpg|25px]] UPDATE- Improved Grids in Dynamic Option Lists ===
 
<table>
 
<table>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
* CNC Bender now properly checks for the PD HOME switch activated before ATTEMPTING to move the FEED axis into the interference zone<br><br>
+
* New grid source with improvements for better performance.
* Previous versions could skip the wait for the PD motion to complete, then give a collision error by not waiting for the PD to move home.<br><br>
+
 
+
* This prevents the following type of error:<br><br>
+
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:feedaxis_icon.jpg]]<br><br>
+
[[image:optionslists.jpg|400px]]
----------------------------------------
+
11/17/2009 2:50:19 PM
+
Collision - The Pressure Die Is Not Home And Feed Would Have Penetrated the Pressure Die Interference Zone, CIO Checked: Input_PressureDieIsHome_End
+
----------------------------------------
+
 
+
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 83: Line 95:
 
<br><br>
 
<br><br>
  
===[[image:Check.jpg|25px]] ENHANCE - AllDiesToHome Command and AllDiesToHomeWithoutPDA Commands===
+
===[[image:Check.jpg|25px]] REPAIR- Counter in RunPage is Updated to Zero When Run is Complete===
  
 
<table>
 
<table>
 +
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
* Both of these commands can now be named in the General Dynamic Option List in Low Level.<br><br>
+
* The part count updated normally except when the Runlist Run is complete.  This is corrected.
* Automated logic has been installed to work like this:
+
 
</td>
 
</td>
 +
 
<td width=450>
 
<td width=450>
 
+
[[image:runpage_counter.jpg|450px]] <br><br>
[[image:COMDEFname_alldiestohome.jpg|450px]] <br><br>
+
 
+
<table cellpadding=5>
+
<tr>
+
<td width=150 bgcolor="#abbad1">
+
* When returning a PDA motion-controlled axis...<br><br>
+
* When using a FOLLOWER with NO prox...
+
 
</td>
 
</td>
  
<td bgcolor="#e3e4f5">
 
...then AllDiesToHomeWithoutPDA is called immediately after in order to insure that the pressure die and clamp dies are home before continuing.
 
</td>
 
 
</tr>
 
</tr>
 
</table>
 
</table>
 
<table cellpadding=5>
 
<tr>
 
<td width=150 bgcolor="#abbad1">
 
* When returning a PDA directional valve actuator...<br><br>
 
* When returning a FOLLOWR with a prox switch...
 
</td>
 
 
<td bgcolor="#e3e4f5">
 
...then AllDiesToHome is called to be sure the pressure die, clamp die, and Pressure Die Assist die are home before continuing.
 
</td>
 
</tr>
 
 
</table>
 
 
</td>
 
</tr>
 
 
</table>
 
 
 
  
 
<br><br>
 
<br><br>

Latest revision as of 23:49, 23 November 2009

Cncbender logo pushbending.png

Type of Upgrade: FLEXIBILITY

The changes in this version are changes to CNC Bender for better flexibility - including new operating systems.

Operatorstation model.jpg



Check.jpg NEW- CNC Bender Can Now Run in 32 or 64 bit Windows Vista and Windows 7

  • CNC Bender previously only ran on Windows 2000 or Windows XP.

  • Now the licensing code is new and allows for operation in Windows Vista and Windows 7 either 32 or 64 bit versions.



Win vista logo.jpg
Win7logo.jpg



Check.jpg NEW- Editor for High Speed Constant Run Processlist

  • The new editor in Low Level allows you to edit the new High Speed Constant Run Processlist.




Highspeed constantrun processlist.jpg



Check.jpg NEW- Better Warning for Missing Processlists

  • Messages now display for missing High Speed Constant Run Processlist

Warning missing processlist file.jpg

Check.jpg UPDATE- Improved Grids in Dynamic Option Lists

  • New grid source with improvements for better performance.

Optionslists.jpg



Check.jpg REPAIR- Counter in RunPage is Updated to Zero When Run is Complete

  • The part count updated normally except when the Runlist Run is complete. This is corrected.

Runpage counter.jpg



Other Pages