VTube-LASER v1.57
Revision 1.57Back to VTube-LASER |
NEW: Recall the BENDER MASTER XYZ to Establish the VTube Master
You can now ask the bender to give you the MASTER XYZ data if that data exists on the bender.
|
ENHANCED: Bender Setup Menu Redesigned
The Bender Setup user interface menu was redesigned.
|
ENHANCED: Negative Lengths or Bend Angles are ZEROED
Bender Lengths and angles that calculate negative values are zeroed. |
ENHANCED: Automatic Springback Compensation for Correction Adjustments
The automatic springback compensation values in the Bender Setup menu are now calculated based on the adjustment value alone.
|
NEW: Transfer Master LRA to Setup LRA Springback Compensation
When transferring data from the VTube MASTER LRA to the BENDER SETUP LRA, automatic springback compensation is automatically applied if the springback values are non-zero. |
NEW: Part Name in Toolbar
The current part name is now displayed in the toolbar below the VTube-LASER logo. |
NEW- Springback Values Transfer from Overbend
VTube-LASER can now receive springback data from Overbend with the press of a single button in the Overbend Calculator. |
NEW: Transfer New Values in Supravision Protocol
New values are included in Supravision file transfers (imports/exports/bender corrections):
|
|
ENHANCED - Other Changes
Other Pages
- Back to VTube-LASER