Difference between revisions of "How to Reverse Engineer with Split Bend"
(→STEP 4: Configure the Measure Setup) |
(→STEP 4: Configure the Measure Setup) |
||
| Line 82: | Line 82: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=400 > | <td width=400 > | ||
| − | + | Configure Measure Setup like this:<br><br> | |
| − | # Press the Measure Setup button in the Navigation pane. | + | # Press the Measure Setup button in the Navigation pane.<br><br> |
| − | # Press the Laser tab if it is not active. | + | # Press the Laser tab if it is not active.<br><br> |
| − | # Activate the LASER scanner for Split Bends. | + | # Activate the LASER scanner for Split Bends.<br><br> |
| − | # Set the number of allowed STRIPES to 250 for Split Bends. | + | # Set the number of allowed STRIPES to 250 for Split Bends.<br><br> |
</td> | </td> | ||
<td width=400 > | <td width=400 > | ||
| Line 94: | Line 94: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=400 > | <td width=400 > | ||
| − | + | Continue with the Measure Setup in the Separation Filter menu<br><br> | |
| − | # Press the Separation Filter tab. | + | # Press the Separation Filter tab.<br><br> |
| − | # Set the SPLIT BEND Scan Type to DISTANCE. | + | # Set the SPLIT BEND Scan Type to DISTANCE.<br><br> |
| − | # Set the SPLIT BEND Scan Distance to 0.039" (or 1 mm). | + | # Set the SPLIT BEND Scan Distance to 0.039" (or 1 mm). <br><br> |
</td> | </td> | ||
<td width=400 > | <td width=400 > | ||
Revision as of 21:17, 9 February 2016
|
How to Reverse Engineer a Part Using Split Bend
|
The Split Bend feature allows you to accurately measure bends that equal or exceed 180 degrees. |
STEP 1: Enter PART SETUP Data
|
Enter the Part Setup data for the new part. Especially enter the PART NUMBER and DEFAULT RADIUS. (You can measure the radius if necessary in Measure Process.) |
STEP 2: Populate the MASTER TUBE DATA Grid
|
Since the Split Bend feature creates a grid based on the number of straights in the MASTER data, it is important to set the number of points that you will be measuring in the reversed tube. |
STEP 3: Configure the Split Bend Window
|
The Split Bend window is on the Bend Setup tab in the MASTER TUBE menu. Click into that window. |
|
|
In the Split Bend window, set any straight that will be treated as a Split Bend. |
STEP 4: Configure the Measure Setup
|
Configure Measure Setup like this:
|
|
|
Continue with the Measure Setup in the Separation Filter menu
|
STEP 5: Measure The Part
|
This step is identical to regular reverse-engineering measuring. |
STEP 6: Choose Build Measured Tube Data Only
|
Because the MASTER data row count is greater than zero, the Measurement Complete window will offer to allow you to ALIGN the measured tube. |
|
|
The new measured tube will appear as a blue tube like this. |
STEP 7: Copy Measured to Master
|
Copy Measured to Master Data in the Data Handling menu. This will overwrite the MASTER data ZEROS with the MEASURED tube data. |
STEP 8: Optional Reset Origin to Zero
|
Some customers prefer to translate the new MASTER data so that the first point is at 0,0,0. |
STEP 9: View the New Master Tube
|
View the new MASTER tube by switching the display of the Master tube on, then redrawing and zooming all. |
STEP 10: Optional Alignment Test
|
This is a cross-check to be sure the process was performed properly. Enter the Inspection Results menu, and press Recalculate for the alignment. |
STEP 11: Save the VTube Project
|
Press the Project Save button in the Toolbar, choose the project save path and filename, and save the VTube Project file. |