Difference between revisions of "VTube-LASER v1.57"
| Line 32: | Line 32: | ||
<br><br> | <br><br> | ||
| + | ===[[image:Check.jpg|25px]] NEW: Transfer New Values in Supravision Protocol === | ||
| + | |||
| + | <table cellpadding=10> | ||
| + | <tr valign=top> | ||
| + | <td width=200> | ||
| + | New values are included in Supravision file transfers (imports/exports/bender corrections): | ||
| + | <br><br> | ||
| + | |||
| + | </td> | ||
| + | <td width=300> | ||
| + | * Comment 1 | ||
| + | * Comment 2 | ||
| + | * Default Radius | ||
| + | * A End Offset | ||
| + | * B End Offset | ||
| + | * Tube Elongation Percentage | ||
| + | * Fixed Springback | ||
| + | * Proportional Springback | ||
| + | </td> | ||
| + | </tr> | ||
| + | </table> | ||
| + | |||
| + | <br><br> | ||
===[[image:Check.jpg|25px]] NEW: Recall the BENDER MASTER XYZ to Establish the VTube Master=== | ===[[image:Check.jpg|25px]] NEW: Recall the BENDER MASTER XYZ to Establish the VTube Master=== | ||
Revision as of 15:49, 12 January 2011
Revision 1.57Back to VTube-LASER |
NEW: Import Supravision Files
|
You can use Supravision project files to setup VTube-LASER.
|
NEW: Transfer New Values in Supravision Protocol
|
New values are included in Supravision file transfers (imports/exports/bender corrections):
|
|
NEW: Recall the BENDER MASTER XYZ to Establish the VTube Master
|
You can now ask the bender to give you the MASTER XYZ data if that data exists on the bender.
|
ENHANCED: Bender Setup Menu Redesigned
|
The Bender Setup user interface menu was redesigned.
|
ENHANCED: Negative Lengths or Bend Angles are ZEROED
|
Bender Lengths and angles that calculate negative values are zeroed. |
ENHANCED: Automatic Springback Compensation for Correction Adjustments
|
The automatic springback compensation values in the Bender Setup menu are now calculated based on the adjustment value alone.
|
NEW: Transfer Master LRA to Setup LRA Springback Compensation
| When transferring data from the VTube MASTER LRA to the BENDER SETUP LRA, automatic springback compensation is automatically applied if the springback values are non-zero. |
NEW: Part Name in Toolbar
|
The current part name is now displayed in the toolbar below the VTube-LASER logo. |
NEW- Springback Values Transfer from Overbend
|
VTube-LASER can now receive springback data from Overbend with the press of a single button in the Overbend Calculator. |