Difference between revisions of "VTube-LASER v1.57"
| Line 13: | Line 13: | ||
__NOTOC__ | __NOTOC__ | ||
| + | |||
| + | |||
| + | ===[[image:Check.jpg|25px]] NEW: Use the BENDER MASTER XYZ to Establish the VTube Master=== | ||
| + | |||
| + | <table cellpadding=10> | ||
| + | <tr valign=top> | ||
| + | <td width=200> | ||
| + | You can now ask the bender to give you the MASTER XYZ data if that data exists on the bender. | ||
| + | <br><br> | ||
| + | The toolbar on the right has a new button that allows you to RECALL MASTER XYZ from a bender to create the MASTER data in VTube. | ||
| + | <br><br> | ||
| + | Before the transfer occurs, VTube will ask you to confirm that you mean to overwrite the MASTER data in VTube.<br><br> | ||
| + | If the incoming bender data does not have MASTER XYZ data, then VTube will warn you and stop the transfer. | ||
| + | </td> | ||
| + | <td width=300> | ||
| + | [[image:vtube-laser_1_57_toolbar_filename.jpg|300px]]. | ||
| + | </td> | ||
| + | </tr> | ||
| + | </table> | ||
| + | |||
| + | <br><br> | ||
| + | |||
| + | |||
| + | ===[[image:Check.jpg|25px]] ENHANCED: Bender Setup Menu Redesigned=== | ||
| + | |||
| + | <table cellpadding=10> | ||
| + | <tr valign=top> | ||
| + | <td width=200> | ||
| + | The Bender Setup user interface menu was redesigned. | ||
| + | <br><br> | ||
| + | * The bender number font size is larger. | ||
| + | * The toolbar on the right is more compact. | ||
| + | </td> | ||
| + | <td width=300> | ||
| + | [[image:vtube-laser_1_57_toolbar_filename.jpg|300px]]. | ||
| + | </td> | ||
| + | </tr> | ||
| + | </table> | ||
| + | |||
| + | <br><br> | ||
| + | |||
| + | |||
| + | ===[[image:Check.jpg|25px]] ENHANCED: Springback Compensation for Correction Adjustments === | ||
| + | |||
| + | <table cellpadding=10> | ||
| + | <tr valign=top> | ||
| + | <td width=200> | ||
| + | The realtime springback compensation values in the Bender Setup menu are now calculated based on the adjustment value alone. So - if the adjustment value for a 90 degree bend is found to be +3 degrees, then the springback compensation added to the bend is calculated based on 3 degrees, not 93 degrees. | ||
| + | </td> | ||
| + | <td width=300> | ||
| + | [[image:vtube-laser_1_57_toolbar_filename.jpg|300px]]. | ||
| + | </td> | ||
| + | </tr> | ||
| + | </table> | ||
| + | |||
| + | <br><br> | ||
| + | |||
| + | |||
| + | ===[[image:Check.jpg|25px]] NEW: Transfer Master LRA to Setup LRA Springback Compensation === | ||
| + | |||
| + | <table cellpadding=10> | ||
| + | <tr valign=top> | ||
| + | <td width=200> | ||
| + | When transferring data from the MASTER LRA to the BENDER SETUP LRA, automatic springback compensation is automatically applied if the springback values are non-zero.</td> | ||
| + | <td width=300> | ||
| + | [[image:vtube-laser_1_57_toolbar_filename.jpg|300px]]. | ||
| + | </td> | ||
| + | </tr> | ||
| + | </table> | ||
| + | |||
| + | <br><br> | ||
| + | |||
===[[image:Check.jpg|25px]] NEW: Part Name in Toolbar === | ===[[image:Check.jpg|25px]] NEW: Part Name in Toolbar === | ||
Revision as of 14:08, 12 January 2011
Revision 1.57Back to VTube-LASER |
NEW: Use the BENDER MASTER XYZ to Establish the VTube Master
|
You can now ask the bender to give you the MASTER XYZ data if that data exists on the bender.
|
ENHANCED: Bender Setup Menu Redesigned
|
The Bender Setup user interface menu was redesigned.
|
ENHANCED: Springback Compensation for Correction Adjustments
|
The realtime springback compensation values in the Bender Setup menu are now calculated based on the adjustment value alone. So - if the adjustment value for a 90 degree bend is found to be +3 degrees, then the springback compensation added to the bend is calculated based on 3 degrees, not 93 degrees. |
NEW: Transfer Master LRA to Setup LRA Springback Compensation
| When transferring data from the MASTER LRA to the BENDER SETUP LRA, automatic springback compensation is automatically applied if the springback values are non-zero. |
NEW: Part Name in Toolbar
|
The current part name is now displayed in the toolbar below the VTube-LASER logo. |
NEW- Springback Values Transfer from Overbend
|
VTube-LASER can now receive springback data from Overbend with the press of a single button in the Overbend Calculator. |
NEW: Transfer New Values in Supravision Protocol
|
New values are included in Supravision file transfers (imports/exports/bender corrections):
|
|
ENHANCED - Other Changes
Other Pages
- Back to VTube-LASER