Difference between revisions of "Revision: Benderlink for Chiyoda/Keins 6.7"
(→25px ENHANCED - New CONVERSION Menu Option: Stop for Zero Diameter) |
(→25px ENHANCED - New CONVERSION Menu Option: Stop for Zero Diameter) |
||
| Line 52: | Line 52: | ||
If this feature is deactivated, then Benderlink will ignore zero value radii values. In this case, Benderlink will automatically change a zero value diameter to non-zero using this formula: | If this feature is deactivated, then Benderlink will ignore zero value radii values. In this case, Benderlink will automatically change a zero value diameter to non-zero using this formula: | ||
<br><br> | <br><br> | ||
| − | (Rad Level 1) / 1.5<br><br> | + | <b>(Rad Level 1) / 1.5</b><br><br> |
If the Rad Level 1 value is zero, then Benderlink will use this formula:<br><br> | If the Rad Level 1 value is zero, then Benderlink will use this formula:<br><br> | ||
| − | (Rad Level 2) / 1.5<br><br> | + | <b>(Rad Level 2) / 1.5</b><br><br> |
If both radius level values are zero, then Benderlink will set the diameter to 1 unit.<br><br>A non-zero diameter is important for communicating with ROMER [[DOCS]] software because DOCS will report a corrupted file if it senses a zero radius. (This is not an issue in [[VTube-LASER]] - it can ignore the diameter of zero.) | If both radius level values are zero, then Benderlink will set the diameter to 1 unit.<br><br>A non-zero diameter is important for communicating with ROMER [[DOCS]] software because DOCS will report a corrupted file if it senses a zero radius. (This is not an issue in [[VTube-LASER]] - it can ignore the diameter of zero.) | ||
Revision as of 01:09, 9 November 2013
Revision 6.7Back to Benderlink for Chiyoda |
ENHANCED - New Serial Port COM Engine Available
|
This Benderlink can use either the new WinSoft COM engine for faster communications, or the older MarshallSoft COM engine for cases where the older engine works better. [Communications Setup] COM Engine=WinSoft or [Communications Setup] COM Engine=Marshallsoft
|
ENHANCED - New CONVERSION Menu Option: Stop for Zero Diameter
|
Benderlink can now stop the process and ask for input if a zero diameter is encountered. If this feature is deactivated, then Benderlink will ignore zero value radii values. In this case, Benderlink will automatically change a zero value diameter to non-zero using this formula:
|
OTHER PAGES
- Back to Benderlink for KEINS
- Back to Benderlink for Chiyoda
- Benderlink for Chiyoda FAQ
- About Chiyoda - See this page for control version information.