Difference between revisions of "End-Scan Using a Ball Probe"
From ATTWiki
(→Measure Setup) |
(→Measure Setup - For End Wall) |
||
| Line 39: | Line 39: | ||
* Set Measure Setup - LASER Tab: The LASER defaults to OFF for at least END-SCANS. | * Set Measure Setup - LASER Tab: The LASER defaults to OFF for at least END-SCANS. | ||
* Set Measure Setup - TACTILE Tab: Uncheck the Continuous Scan on Tactile End-Scans. | * Set Measure Setup - TACTILE Tab: Uncheck the Continuous Scan on Tactile End-Scans. | ||
| − | * Set Measure Setup - TACTILE Tab: Set the Offset for each end to "TOWARD BEND" if the measurement is on the end wall. | + | * Set Measure Setup - TACTILE Tab: Set the Offset for each end to "TOWARD BEND" if the measurement is on the end wall. |
| + | </td> | ||
| + | <td width=300> | ||
| + | </td> | ||
| + | </tr> | ||
| + | </table> | ||
| + | |||
| + | ===Measure Setup - For End Surface=== | ||
| + | <table cellpadding=10> | ||
| + | <tr valign=top> | ||
| + | <td width=500> | ||
| + | Follow the instructions above except change the End A Offset to AWAY like this: | ||
| + | * Set Measure Setup - TACTILE Tab: Set the Offset "AWAY" if the tube end is moving into a surface. | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
Revision as of 00:13, 22 June 2012
|
|
Why the End-Scan technique is important
|
This end-scan method is useful for situations where the only option is a ball probe - or where the Laser cannot reach effectively - but a ball probe can.
|
Measure Setup - For End Wall
|
Measure Setup - For End Surface
|
Follow the instructions above except change the End A Offset to AWAY like this:
|
How To Use This End-Scan Technique
|
Other Pages
- See also End-Scan Using the End Wall
- See also End-Scan Using End Targets
- Back to VTube-LASER