Difference between revisions of "VTube-LASER v1.63"

From ATTWiki
Jump to: navigation, search
 
(25px NEW: Scan Rate Types: Timer or Distance)
Line 35: Line 35:
 
<br><br>
 
<br><br>
  
===[[image:Check.jpg|25px]] NEW: Scan Rate Types: Timer or Distance===
+
===[[image:Check.jpg|25px]] Other Changes===
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=200>
 
<td width=200>
Now all scan rates are determined by either a TIMER or a DISTANCE.
+
*Updated the graphics engine for faster redraws.
 
<br><br>
 
<br><br>
For end-scans, use a timer and set the timer value to 0 milliseconds.<br><br>
+
Added more report values - master length, measured length, delta between measured and master, bender setup LRA<br><br>
For cylinder scans, you can use DISTANCE and set the Cylinder Scan Distance to whatever value is convenient for separation.
+
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:vtube-laser_measuresetup_scanrates.jpg|300px]]<br><br>
 
 
</td>
 
</td>
 
</tr>
 
</tr>

Revision as of 16:12, 1 April 2011

Vtube-laser logo.jpg

Revision 1.63

Back to VTube-LASER

Vtube-laser 1 63.jpg



Check.jpg NEW: Select and Configure any number of Reports

The Report menu was redesigned so that operators choose from a list of report templates to show any one of several reports.

  • Edit the list (Add, Delete, Move the template up or down).
  • Edit any template in the included Notepad++ editor (installs with v1.63).
  • Explore the folder that contains the templates.
  • Give the report template a new name.
  • There is no limitation on the number of templates allowed.
  • The report template setup is stored local to the computer (not in project files).

Vtube-laser report templates control.jpg



Check.jpg Other Changes

  • Updated the graphics engine for faster redraws.



Added more report values - master length, measured length, delta between measured and master, bender setup LRA



Check.jpg NEW: Multiple Point Qualification End Scan

VTube-LASER now uses multiple points to qualify the end-scan. This gives it better protection against outlier points.

A new End-Scan Fit window gives information about how many points were used in the end-trim, and the span of all the point positions. Higher point counts with lower spans indicate a better data set for end-trim.

Vtube-laser endscan fitwindow.jpg



Check.jpg REPAIR: Diameter and Wall Detection for STEP Mode

See VTube-STEP v1.62 for details.

Vtube-step 1 62.jpg



Check.jpg Other Changes

  • The A End and B End OFFSETs other than ZERO caused a problem where end-scans would never be qualified. This has been resolved in this version.



Check.jpg Issues with this version fixed in newer versions

  • No known issues

Other Pages

VTube-LASER Training Video - How to perform effective end scans.

Vtube-laser effective end scan video b.jpg