Difference between revisions of "VTube-LASER v1.64b"
From ATTWiki
| (11 intermediate revisions by one user not shown) | |||
| Line 16: | Line 16: | ||
===[[image:Check.jpg|25px]] NEW: Transfluid Bender Communications=== | ===[[image:Check.jpg|25px]] NEW: Transfluid Bender Communications=== | ||
| − | [[image:vtube-laser-transfluid_communication.jpg| | + | [[image:vtube-laser-transfluid_communication.jpg|400px]]<br><br> |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=200> | <td width=200> | ||
| − | + | VTube-LASER can now communicate with Transfluid benders. The protocol is a file-based protocol based on Transfluid bender file format version 2. | |
| + | <br><br> | ||
| + | We added this protocol to meet the requirements of a customer that purchased VTube-LASER and a FARO 15 foot arm system. | ||
| + | </td> | ||
| + | <td width=300> | ||
| + | </td> | ||
| + | </tr> | ||
| + | </table> | ||
| + | |||
| + | <br><br> | ||
| + | |||
| + | ===[[image:Check.jpg|25px]] NEW: Radius Stripe Scanning=== | ||
| + | <table cellpadding=10> | ||
| + | <tr valign=top> | ||
| + | <td width=200> | ||
| + | The new radius stripe scanning method is easier to use than the segment scan method in previous versions. It is also more accurate. | ||
| + | <br><br> | ||
| + | The segment scan-method is no longer available because it is replaced with this new method. | ||
| + | <br><br> | ||
| + | The help file and manual is updated to show how to measure with the radius stripe scan method. | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
| + | [[image:vtube-laser_radius_stripe_scanning.jpg|300px]] | ||
</td> | </td> | ||
</tr> | </tr> | ||
| Line 47: | Line 67: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=500> | <td width=500> | ||
| − | * | + | * The MOVE command was repaired in [[VTube-LASER v1.65]]</td> |
<td width=300> | <td width=300> | ||
</td> | </td> | ||
Latest revision as of 07:50, 19 May 2011
Revision 1.64bBack to VTube-LASER |
NEW: Transfluid Bender Communications
|
VTube-LASER can now communicate with Transfluid benders. The protocol is a file-based protocol based on Transfluid bender file format version 2.
|
NEW: Radius Stripe Scanning
|
The new radius stripe scanning method is easier to use than the segment scan method in previous versions. It is also more accurate.
|
Other Changes
|
Issues with this version fixed in newer versions
|
Other Pages
- Back to VTube-LASER
|
VTube-LASER Training Video - How to perform effective end scans. |