Difference between revisions of "VTube-LASER v1.55"
(6 intermediate revisions by one user not shown) | |||
Line 21: | Line 21: | ||
Since radius sections are often highly distorted with ovality and changing radius values along the bend, this new radius scan-segment measurement method allows for more accurate averaging of radius measurement for reverse-engineering of radius values by allowing users to scan as many as 10 arc segments if necessary for better averaging of radius values. | Since radius sections are often highly distorted with ovality and changing radius values along the bend, this new radius scan-segment measurement method allows for more accurate averaging of radius measurement for reverse-engineering of radius values by allowing users to scan as many as 10 arc segments if necessary for better averaging of radius values. | ||
<br><br> | <br><br> | ||
− | The Set Segment Scan Count box | + | The new Set Segment Scan Count box allows you to enter from 3 to 10 segments to measure per arc. (Also see the enhanced Measure Process menu below.) |
<br><br> | <br><br> | ||
Line 60: | Line 60: | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
+ | ===[[image:Check.jpg|25px]] FIX - Measure Tube XYZ Data Build === | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=200> | ||
+ | This version fixes a bug found in version 1.54 where the Measured XYZ data may not update after a measure.<br><br> | ||
+ | Please be sure to use this version rather than v1.54. | ||
+ | <br><br> | ||
+ | </td> | ||
+ | <td> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | ===[[image:Check.jpg|25px]] ENHANCED - Best Fit Alignment Mathematics === | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=200> | ||
+ | New features were added to prevent unnecessary errors/warnings from displaying for parts that align too closely with the master part. | ||
+ | <br><br> | ||
+ | </td> | ||
+ | <td> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
=Other Pages= | =Other Pages= | ||
*Back to [[VTube-LASER]] | *Back to [[VTube-LASER]] |
Latest revision as of 02:53, 5 January 2011
Revision 1.55Back to VTube-LASER |
NEW: Radius Segment Scan Method
Since radius sections are often highly distorted with ovality and changing radius values along the bend, this new radius scan-segment measurement method allows for more accurate averaging of radius measurement for reverse-engineering of radius values by allowing users to scan as many as 10 arc segments if necessary for better averaging of radius values.
|
ENHANCED - Measure Process Menu
The enhanced Measure Process menu is reorganized. The menu includes the new Straight Count box - which was moved from the Measure Setup menu. |
ENHANCED - Measure Setup Menu
The Measure Setup program is condensed because the Straight Count setting has been moved to the Measure Process menu for consistency. |
FIX - Measure Tube XYZ Data Build
This version fixes a bug found in version 1.54 where the Measured XYZ data may not update after a measure. Please be sure to use this version rather than v1.54.
|
ENHANCED - Best Fit Alignment Mathematics
New features were added to prevent unnecessary errors/warnings from displaying for parts that align too closely with the master part.
|
Other Pages
- Back to VTube-LASER