Difference between revisions of "VTube-STEP v2.9.5"
(→25pxNEW - BEND-TECH 7X IMPORT) |
(→Revision 2.9.5) |
||
| (10 intermediate revisions by one user not shown) | |||
| Line 4: | Line 4: | ||
[[image:vtube-step_logo_2.png|300px]] | [[image:vtube-step_logo_2.png|300px]] | ||
==Revision 2.9.5== | ==Revision 2.9.5== | ||
| − | + | Release Date: March 2, 2018<br> | |
| − | Release Date: | + | |
| Line 49: | Line 48: | ||
<td width=400> | <td width=400> | ||
| − | + | Now VTube can import the new BEND-TECH 7x format as well as the older version 6 format. | |
</td> | </td> | ||
<td> | <td> | ||
[[image:vts_2.9.5_bend-tech_7x_import.png|600px]] | [[image:vts_2.9.5_bend-tech_7x_import.png|600px]] | ||
| + | </td> | ||
| + | </tr> | ||
| + | |||
| + | </table> | ||
| + | <br><br> | ||
| + | |||
| + | ==[[image:Check.jpg|25px]]NEW - DENGLER VDS IMPORT (XYZ Data)== | ||
| + | |||
| + | <table cellpadding=10 width=800> | ||
| + | <tr valign=top> | ||
| + | |||
| + | <td width=400> | ||
| + | VTube can now import DENGLER VDS files. (DENGLER VDS files contain centerline XYZ coordinates.) | ||
| + | </td> | ||
| + | |||
| + | <td> | ||
| + | [[image:vts_2.9.5_dengler_vds_import.png|600px]] | ||
| + | </td> | ||
| + | </tr> | ||
| + | |||
| + | </table> | ||
| + | <br><br> | ||
| + | |||
| + | |||
| + | ==[[image:Check.jpg|25px]]NEW - DENGLER VDS EXPORT(XYZ Data)== | ||
| + | |||
| + | <table cellpadding=10 width=800> | ||
| + | <tr valign=top> | ||
| + | |||
| + | <td width=400> | ||
| + | VTube can now exportDENGLER VDS files. (DENGLER VDS files contain centerline XYZ coordinates.) | ||
| + | </td> | ||
| + | |||
| + | <td> | ||
| + | [[image:vts_2.9.5_dengler_vds_export.png|600px]] | ||
</td> | </td> | ||
</tr> | </tr> | ||
| Line 118: | Line 152: | ||
<br><br> | <br><br> | ||
| + | |||
| + | ==[[image:Check.jpg|25px]]NEW - MINIMUM CLAMP LENGTH== | ||
| + | |||
| + | <table cellpadding=10 width=900> | ||
| + | <tr valign=top> | ||
| + | |||
| + | <td width=400> | ||
| + | VTube has a new Minimum Clamp Length field in the Part Setup menu.<br><br> | ||
| + | If any bender data length is shorter than the minimum clamp length, then VTube will now issue a warning in the header above the viewport. | ||
| + | </td> | ||
| + | |||
| + | <td> | ||
| + | [[image:vts_2.9.5_minimum_clamp_length.png|600px]]<br><br> | ||
| + | </td> | ||
| + | </tr> | ||
| + | |||
| + | </table> | ||
| + | <br><br> | ||
| + | |||
| + | ==[[image:Check.jpg|25px]]NEW - ZERO-DEGREE BEND ANGLE WARNING== | ||
| + | |||
| + | <table cellpadding=10 width=900> | ||
| + | <tr valign=top> | ||
| + | |||
| + | <td width=400> | ||
| + | If any bend angle is less than 0.1 degrees, VTube will now issue a "Zero-degree bend" warning in the header above the viewport. | ||
| + | </td> | ||
| + | |||
| + | <td> | ||
| + | [[image:vts_2.9.5_zero-degree_bend.png|600px]]<br><br> | ||
| + | </td> | ||
| + | </tr> | ||
| + | |||
| + | </table> | ||
| + | <br><br> | ||
=Other Pages= | =Other Pages= | ||
Latest revision as of 00:04, 14 March 2018
Revision 2.9.5Release Date: March 2, 2018
|
ENHANCED - FASTER USER INTERFACE
|
VTube is now faster due to some important changes to the user interface. |
NEW - BEND-TECH 7X IMPORT
|
Now VTube can import the new BEND-TECH 7x format as well as the older version 6 format. |
NEW - DENGLER VDS IMPORT (XYZ Data)
|
VTube can now import DENGLER VDS files. (DENGLER VDS files contain centerline XYZ coordinates.) |
NEW - DENGLER VDS EXPORT(XYZ Data)
|
VTube can now exportDENGLER VDS files. (DENGLER VDS files contain centerline XYZ coordinates.) |
FIX - SOLID MODEL IMAGE PRINT IN REPORTS
|
VTube is designed to handle multiple displays. |
FIX - REPAIRED LOSS OF ORIGINAL ORIENTATION DURING REVERSE CALC
|
VTube always attempts to keep the original XYZ orientation when you perform a Reverse Calc from LRA to centerline XYZ data. |
FIX - BUILD TO TUBE TO SOLIDWORKS
|
VTube would incorrectly build a single tube to both a single part drawing and a SOLIDWORKS assembly. |
NEW - MINIMUM CLAMP LENGTH
|
VTube has a new Minimum Clamp Length field in the Part Setup menu. |
NEW - ZERO-DEGREE BEND ANGLE WARNING
|
If any bend angle is less than 0.1 degrees, VTube will now issue a "Zero-degree bend" warning in the header above the viewport. |
Other Pages
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.