Difference between revisions of "VTube-LASER v2.9.5"

From ATTWiki
Jump to: navigation, search
(25pxNEW - REQUEST REVERSE CALC WHEN EXITING THE LRA GRIDS)
(Revision 2.9.5)
 
(25 intermediate revisions by one user not shown)
Line 6: Line 6:
  
 
==Revision 2.9.5==
 
==Revision 2.9.5==
Release Date: February 19, 2018<br>
+
Release Date: March 2, 2018<br>
Build:  
+
Build: 1
  
 
* Back to [[VTube-LASER]]
 
* Back to [[VTube-LASER]]
Line 24: Line 24:
 
__TOC__
 
__TOC__
  
==[[image:Check.jpg|25px]]ENHANCED- FASTER USER INTERFACE==
+
==[[image:Check.jpg|25px]]ENHANCED - FASTER USER INTERFACE==
  
 
<table cellpadding=10 width=800>
 
<table cellpadding=10 width=800>
Line 34: Line 34:
  
 
<td>
 
<td>
 +
[[image:VTL Single Tube with shadow.png|400px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 46: Line 47:
  
 
<td width=400>
 
<td width=400>
VTube handles multiple displays.<br><br>
+
VTube is designed to handle multiple displays.<br><br>
 
We discovered that, for windows arrangements where the Windows Desktop is not on the far left monitor, VTube might not print the graphics image properly in reports.<br><br>This has been fixed in this version.
 
We discovered that, for windows arrangements where the Windows Desktop is not on the far left monitor, VTube might not print the graphics image properly in reports.<br><br>This has been fixed in this version.
 
</td>
 
</td>
Line 57: Line 58:
 
</table>
 
</table>
 
<br><br>
 
<br><br>
 
  
 
==[[image:Check.jpg|25px]]NEW - SEPARATE PERSPECTIVE MODES FOR STEP and LASER WINDOWS==
 
==[[image:Check.jpg|25px]]NEW - SEPARATE PERSPECTIVE MODES FOR STEP and LASER WINDOWS==
Line 92: Line 92:
 
<td>
 
<td>
 
[[image:vtl_2.9.5 request reverse calc.png|600px]]
 
[[image:vtl_2.9.5 request reverse calc.png|600px]]
 +
</td>
 +
</tr>
 +
 +
</table>
 +
<br><br>
 +
 +
 +
 +
 +
==[[image:Check.jpg|25px]]FIX - REPAIRED LOSS OF ORIGINAL ORIENTATION DURING REVERSE CALC==
 +
 +
<table cellpadding=10 width=800>
 +
<tr valign=top>
 +
 +
<td width=400>
 +
VTube always attempts to keep the original XYZ orientation when you perform a Reverse Calc from LRA to centerline XYZ data.<br><br>
 +
We discovered that certain situations would cause VTube to lose the orientation during Reverse Calc.<br><br>
 +
This has been fixed in this version.
 +
</td>
 +
 +
<td>
 +
[[image:vts_2.9.5_reversecalc_loss_orientation.png|400px]]<br><br>
 +
[[image:vts_2.9.5_reversecalc_noloss_orientation.png|400px]]<br><br>
 +
</td>
 +
</tr>
 +
 +
</table>
 +
<br><br>
 +
 +
==[[image:Check.jpg|25px]]FIX - BUILD TO TUBE TO SOLIDWORKS==
 +
 +
<table cellpadding=10 width=800>
 +
<tr valign=top>
 +
 +
<td width=400>
 +
VTube would incorrectly build a single tube to both a single part drawing and a SOLIDWORKS assembly.<br><br>If VTube is building a single tube in SOLIDWORKS the best action is to always build a single part drawing.<br><br>
 +
The build logic has been fixed in this version.<br><br>
 +
If there are multiple parts in VTube, then VTube will still allow you to choose between building all the parts into one drawing, or building all the parts into a SOLIDWORKS assembly.
 +
</td>
 +
 +
<td>
 +
[[image:vtl_2.9.5_swtrans.png|400px]]<br><br>
 +
</td>
 +
</tr>
 +
 +
</table>
 +
<br><br>
 +
 +
==[[image:Check.jpg|25px]]NEW - BEND-TECH 7X IMPORT==
 +
 +
<table cellpadding=10 width=800>
 +
<tr valign=top>
 +
 +
<td width=400>
 +
Now VTube can import the new BEND-TECH 7x format as well as the older version 6 format.
 +
</td>
 +
 +
<td>
 +
[[image:vts_2.9.5_bend-tech_7x_import.png|600px]]
 +
</td>
 +
</tr>
 +
 +
</table>
 +
<br><br>
 +
 +
==[[image:Check.jpg|25px]]NEW - DENGLER VDS IMPORT (XYZ Data)==
 +
 +
<table cellpadding=10 width=800>
 +
<tr valign=top>
 +
 +
<td width=400>
 +
VTube can now import DENGLER VDS files.  (DENGLER VDS files contain centerline XYZ coordinates.)
 +
</td>
 +
 +
<td>
 +
[[image:vts_2.9.5_dengler_vds_import.png|600px]]
 +
</td>
 +
</tr>
 +
 +
</table>
 +
<br><br>
 +
 +
 +
==[[image:Check.jpg|25px]]NEW - DENGLER VDS EXPORT(XYZ Data)==
 +
 +
<table cellpadding=10 width=800>
 +
<tr valign=top>
 +
 +
<td width=400>
 +
VTube can now export DENGLER VDS files.  (DENGLER VDS files contain centerline XYZ coordinates.)
 +
</td>
 +
 +
<td>
 +
[[image:vts_2.9.5_dengler_vds_export.png|600px]]
 +
</td>
 +
</tr>
 +
 +
</table>
 +
<br><br>
 +
 +
 +
 +
==[[image:Check.jpg|25px]]NEW - MINIMUM CLAMP LENGTH==
 +
 +
<table cellpadding=10 width=900>
 +
<tr valign=top>
 +
 +
<td width=400>
 +
VTube has a new Minimum Clamp Length field in the Part Setup menu.<br><br>
 +
If any bender data length is shorter than the minimum clamp length, then VTube will now issue a warning in the header above the viewport.
 +
</td>
 +
 +
<td>
 +
[[image:vts_2.9.5_minimum_clamp_length.png|600px]]<br><br>
 +
</td>
 +
</tr>
 +
 +
</table>
 +
<br><br>
 +
 +
==[[image:Check.jpg|25px]]NEW - ZERO-DEGREE BEND ANGLE WARNING==
 +
 +
<table cellpadding=10 width=900>
 +
<tr valign=top>
 +
 +
<td width=400>
 +
If any bend angle is less than 0.1 degrees, VTube will now issue a "Zero-degree bend" warning in the header above the viewport.
 +
</td>
 +
 +
<td>
 +
[[image:vts_2.9.5_zero-degree_bend.png|600px]]<br><br>
 
</td>
 
</td>
 
</tr>
 
</tr>

Latest revision as of 00:03, 14 March 2018

Vtube-laser logo 1.96.png


Revision 2.9.5

Release Date: March 2, 2018
Build: 1


Vtube-laser v2.7 screenshot.png

Contents


Check.jpgENHANCED - FASTER USER INTERFACE

VTube is now faster due to some important changes to the user interface.

VTL Single Tube with shadow.png



Check.jpgFIX - SOLID MODEL IMAGE PRINT IN REPORTS

VTube is designed to handle multiple displays.

We discovered that, for windows arrangements where the Windows Desktop is not on the far left monitor, VTube might not print the graphics image properly in reports.

This has been fixed in this version.

Vtl report header.png



Check.jpgNEW - SEPARATE PERSPECTIVE MODES FOR STEP and LASER WINDOWS

In previous versions, there was only a single Perspective Mode switch.

In this version, there is a separate Perspective Mode switch for STEP and LASER windows.

Vtl 2.9.5 perspective.png
Vts 2.9.5 perspective.png




Check.jpgNEW - REQUEST REVERSE CALC WHEN EXITING THE LRA GRIDS

When you edit the data in the LRA grid, VTube-LASER now assumes that you probably mean to perform a reverse calc.

If you exit the grid without a reverse calc, then it will immediately ask if you intended to perform a Reverse Calc - and allow you to choose to calculate the XYZ data.

This is active in both the MASTER and the MEASURED LRA grids.

Vtl 2.9.5 request reverse calc.png





Check.jpgFIX - REPAIRED LOSS OF ORIGINAL ORIENTATION DURING REVERSE CALC

VTube always attempts to keep the original XYZ orientation when you perform a Reverse Calc from LRA to centerline XYZ data.

We discovered that certain situations would cause VTube to lose the orientation during Reverse Calc.

This has been fixed in this version.

Vts 2.9.5 reversecalc loss orientation.png

Vts 2.9.5 reversecalc noloss orientation.png



Check.jpgFIX - BUILD TO TUBE TO SOLIDWORKS

VTube would incorrectly build a single tube to both a single part drawing and a SOLIDWORKS assembly.

If VTube is building a single tube in SOLIDWORKS the best action is to always build a single part drawing.

The build logic has been fixed in this version.

If there are multiple parts in VTube, then VTube will still allow you to choose between building all the parts into one drawing, or building all the parts into a SOLIDWORKS assembly.

Vtl 2.9.5 swtrans.png



Check.jpgNEW - BEND-TECH 7X IMPORT

Now VTube can import the new BEND-TECH 7x format as well as the older version 6 format.

Vts 2.9.5 bend-tech 7x import.png



Check.jpgNEW - DENGLER VDS IMPORT (XYZ Data)

VTube can now import DENGLER VDS files. (DENGLER VDS files contain centerline XYZ coordinates.)

Vts 2.9.5 dengler vds import.png




Check.jpgNEW - DENGLER VDS EXPORT(XYZ Data)

VTube can now export DENGLER VDS files. (DENGLER VDS files contain centerline XYZ coordinates.)

Vts 2.9.5 dengler vds export.png




Check.jpgNEW - MINIMUM CLAMP LENGTH

VTube has a new Minimum Clamp Length field in the Part Setup menu.

If any bender data length is shorter than the minimum clamp length, then VTube will now issue a warning in the header above the viewport.

Vts 2.9.5 minimum clamp length.png



Check.jpgNEW - ZERO-DEGREE BEND ANGLE WARNING

If any bend angle is less than 0.1 degrees, VTube will now issue a "Zero-degree bend" warning in the header above the viewport.

Vts 2.9.5 zero-degree bend.png



Other Pages