== About Automated Layout Transfers to AutoCAD ==
+
== Automated Layout Transfers to AutoCAD ==
  
TubeCAD can send data to AutoCAD automatically.  This means it can load AutoCAD, then load the DXF file automatically.  Older versions of TubeCAD would always build the DXF and script files for AutoCAD in the ACAD.EXE folder.  This worked in Windows XP, but can present problems in Windows 7 and 8.<br><br>
+
TubeCAD can send data to AutoCAD automatically.  This means it can load AutoCAD, then load the DXF file automatically.  Older versions of TubeCAD would always build the DXF and script files for AutoCAD in the ACAD.EXE folder.  This worked in Windows XP, but can present problems in Windows 7 or newer.<br><br>
The reason is that Windows 7 and 8, by default, make that folder read-only to TubeCAD.  The way around this problem is to allow TubeCAD to store the DXF data in folders where read-write are allowed for the user logged into the current Windows session.<br><br>This document describes how to change the path to allow for the automated transfer.<br><br>
+
The reason is that Windows 7 or newer, by default, make that folder read-only to TubeCAD.  This setup will allow AutoCAD to load, but will report errors loading the imported layout and will show a blank screen.  If you see this behavior, then the issue is probably an invalid DXF Build Location path in TubeCAD.<br><br>
 +
The way to fix this problem is to allow TubeCAD to store the DXF data in folders where read-write are allowed for the user logged into the current Windows session.
 +
<br><br><br><br>
  
 
==TubeCAD Options Menu==
 
==TubeCAD Options Menu==
The options menu can be loaded by right-clicking on the viewport in TubeCAD.  Then choose "options".
+
The DXF Build Location can be setup in the options menu.  The options menu can be loaded by right-clicking on the viewport in TubeCAD.  Then choose "options".
 
<br><br>
 
<br><br>
 
[[image:tcadpro-popup-viewport.png]]
 
[[image:tcadpro-popup-viewport.png]]
 +
<br><br><br><br>
  
==DXF Path==
+
==DXF Build Location==
The DXF Path<br><br>
+
  
[[image:blah.png|400px]]
+
The DXF Build Location is where all temporary DXF files are built, and where all manual DXF files start in a save dialog.
  
By default, the path assigned is supposed to allow read-write of files.  It will have this form: '''c:\users\<username>\AppData\Roaming\tcadpro'''<br><br>
+
The path assigned by TubeCAD for building DXF files is supposed to allow read-write of files per the rules used by WindowsEdit the DXF Build Location path in this window:<br><br>
  
Note: The common configuration folders and files are only copied when the same folders and files ''do not already exist'' in the user's private folder.<br><br>
+
[[image:tcadpro_options_dxfpath.png|600px]]<br><br>
  
==Where Each User's Part Data is Stored Initially==
+
This path is persistent.  That is, it will be remembered for the next session of TubeCAD - even if you clear the layout or close TubeCAD.  (The version released November 12, 2013 fixed a problem where TubeCAD would not remember this path.)<br><br>
The bender and measuring center files are stored in '''Documents\tcadpro'''.<br><br>
+
  
If these folders and the sample files in them do not exist when tcadpro starts, then TubeCAD will copy initial starting part files from the common folder.<br><br>
+
If this path does not work for building DXF files, then you can choose another build location.<br><br>
Note: The common set of initial user's data are only copied from the common setup folder when the same folders and files ''do not already exist'' in the user's private Documents folder.<br><br>
+
<br><br><br><br>
 
+
==TubeCAD Project Path Assigned Inside TubeCAD Initially==
+
TubeCAD will also automatically assign the same private Documents location as the default project file storage path for each bender inside the TubeCAD File menu.
+
<br><br>
+
  
 
==Other Pages==
 
==Other Pages==
  
 
*Back to [[TubeCAD Pro]]
 
*Back to [[TubeCAD Pro]]

Latest revision as of 13:04, 2 August 2017

Tcadpro logo.jpg

Choosing a DXF Path for AutoCAD

Back to TubeCAD Pro

Tcadpro demo generated.jpg



Automated Layout Transfers to AutoCAD

TubeCAD can send data to AutoCAD automatically. This means it can load AutoCAD, then load the DXF file automatically. Older versions of TubeCAD would always build the DXF and script files for AutoCAD in the ACAD.EXE folder. This worked in Windows XP, but can present problems in Windows 7 or newer.

The reason is that Windows 7 or newer, by default, make that folder read-only to TubeCAD. This setup will allow AutoCAD to load, but will report errors loading the imported layout and will show a blank screen. If you see this behavior, then the issue is probably an invalid DXF Build Location path in TubeCAD.

The way to fix this problem is to allow TubeCAD to store the DXF data in folders where read-write are allowed for the user logged into the current Windows session.



TubeCAD Options Menu

The DXF Build Location can be setup in the options menu. The options menu can be loaded by right-clicking on the viewport in TubeCAD. Then choose "options".

Tcadpro-popup-viewport.png



DXF Build Location

The DXF Build Location is where all temporary DXF files are built, and where all manual DXF files start in a save dialog.

The path assigned by TubeCAD for building DXF files is supposed to allow read-write of files per the rules used by Windows. Edit the DXF Build Location path in this window:

Tcadpro options dxfpath.png

This path is persistent. That is, it will be remembered for the next session of TubeCAD - even if you clear the layout or close TubeCAD. (The version released November 12, 2013 fixed a problem where TubeCAD would not remember this path.)

If this path does not work for building DXF files, then you can choose another build location.