Revision as of 22:14, 7 October 2016
About this Page
This page describes the setup and use of the VTube to AMOB communications. |
The Basics of How It Works
|
Communications Setup at the SOCO Bender
|
Setup Benderlink at VTube-STEP or VTube-LASER
Entering Benderlink Setup
|
Setup the Benderlink Network Grid for the SOCO Bender
|
How to SEND MASTER BENDER Data to the AMOB Control from VTube-STEP
You can import data into VTube-STEP then send the bender data calculated to the AMOB bender using the VTube Input/Export menu. |
At the VTube-STEP Main ScreenMove to the VTube-STEP computer and follow these steps to transfer the bender data to the AMOB.
|
At the AMOB Bender Data Export Window (inside VTube-STEP)Press the Export button to save a VTL file on the network at the shared path for the AMOB bender. |
How to SEND CORRECTION Data to the AMOB Control from VTube-LASER
After Bending the Tube
Bend a tube then measure it with VTube-LASER.
Measure the tube with VTube-LASERMeasure and align the tube to determine if it qualifies by falling within the envelope tolerance for the tube shape.
|
Correct the AMOB with VTube-LASER - Enter BENDER SETUPFollow these steps in the VTube-LASER: Press the "BENDER SETUP button in the Navigation Pane. |
INITIAL Setup of Bender Setup WindowThe first time in this window for a new part will require these steps before you can correct the AMOB bender. STEP 1 - Set the correct bender number at the top of the window. The AMOB bender should display if you have already setup the bender protocol in the Benderlink grid.
|
Check the BLUE COLUMN DataThe LRA blue column data is now filled with the MASTER LRA data. This data MUST match the X axis, Y axis, Z axis bender data at the bender - or the corrections will be incorrect.
|
Send the Corrections to the AMOB VTL FileSave the Correction data to the file for the AMOB to import.
|
Import the Correction Data At the AMOB ControlSave the Correction data to the file for the AMOB to import.
|
AMOB Control Bender Data UpdatedThe bender data will be updated with the new values. |
Other Pages
- See VTube-LASER
- See VTube-STEP
- See SOCO for information on the SOCO benders
- See Video 62 - SOCO Communications Video to see an actual corrections loop with a SOCO bender.